Covered stents for treatment of visceral artery aneurysms: a multicenter study

C Qiu, Z Liu, L Huang, L Guo, W Lu, H Zhang… - Journal of Vascular and …, 2022 - Elsevier
Purpose To evaluate the safety and efficacy of covered stents for treatment of visceral artery
aneurysms (VAA). Methods This multicenter retrospective study included patients with VAAs …

Implantation of large diameter (5.5–6 mm) derivo embolization devices for the treatment of cerebral aneurysms

W Butt, C Kim, R Ramaswamy, A Smith… - Clinical Neuroradiology, 2022 - Springer
Background The efficacy of flow diverters is dependent upon robust wall apposition in the
parent artery. Usage in large caliber cerebral vessels has therefore been limited as few …

Correspondence on “Delayed collapse of flow diverter due to acute severe vasospasm: another concern for flow diversion in ruptured aneurysms” by Kumar et al

F Mistretta, R Russo, S Molinaro… - Journal of …, 2023 - jnis.bmj.com
Provenance and peer review Not commissioned; internally peer reviewed. Supplemental
material This content has been supplied by the author (s). It has not been vetted by BMJ …

The safety and efficacy of flow diversion versus conventional endovascular treatment for intracranial aneurysms: a meta-analysis of real-world cohort studies from the …

S Li, C Zeng, W Tao, Z Huang, L Yan… - American Journal of …, 2022 - Am Soc Neuroradiology
BACKGROUND: Although the flow diverter has advantages in the treatment of intracranial
aneurysms, pooled studies that directly compare it with conventional endovascular …

[PDF][PDF] Subarachnoid haemorrhage caused by a ruptured aneurysm: diagnosis and management

N guideline NG228 - Methods, 2022 - ncbi.nlm.nih.gov
People with a confirmed diagnosis of aneurysmal subarachnoid haemorrhage are at risk of
rebleeding, disability and death. In current practice patients are considered for …

[HTML][HTML] Effects of two different glycoprotein platelet IIb/IIIa inhibitors and the clinical endpoints in patients with intracranial Pipeline flow diverter implant

Q Deng, S Zhang, M Li, G Zhang, W Feng - Journal of Interventional …, 2020 - Elsevier
Objective To compare the antiplatelet effect and major adverse cerebrovascular events of
Pipeline for intracranial aneurysms using glycoprotein IIb/IIIa antagonists (GPI) eptifibatide …

T-stent or half T-stent-assisted embolization of wide-necked aneurysms at the internal carotid-posterior communicating artery bifurcation

T Nakajo, T Terada, H Okada, H Sakaguchi… - Journal of …, 2021 - jstage.jst.go.jp
Objective: We report the usefulness and pitfalls of coil embolization using the T or half T-
stent technique for aneurysms located at internal carotid artery-posterior communicating …

[HTML][HTML] The exchange-free technique: a novel technique for enhancing Surpass flow diverter placement

O Ocal, A Arat - Asian journal of neurosurgery, 2020 - thieme-connect.com
Background: Following flow diverter placement, approximately 20% of intracranial
aneurysms remain as residual aneurysms at 1 year. Device malapposition is a cause of …

[HTML][HTML] Flow diverter stent for treatment of cerebral aneurysms: A report of 24 patients with 25 Devices: aneurysms: A Single-Center Experience

A Davila, D Valer, H Cañari - J Comm Med and Pub …, 2021 - acquaintpublications.com
Background: This study aims to report our experience with cerebral aneurysms, which may
improve in the treatment with the flow-diverter stent and follow-up. Methods: This study was …