[HTML][HTML] Unfavorable vascular anatomy during endovascular treatment of stroke: challenges and bailout strategies
FJA MontAlverne, FO Lima, F de Araújo Rocha… - Journal of …, 2020 - ncbi.nlm.nih.gov
The benefit of mechanical thrombectomy (MT) in acute ischemic stroke (AIS) due to large
vessel intracranial occlusions is directly related to the technical success of the procedures in …
vessel intracranial occlusions is directly related to the technical success of the procedures in …
Clinical and procedural outcomes with or without balloon guide catheters during endovascular thrombectomy in acute ischemic stroke: a systematic review and meta …
A Podlasek, PS Dhillon, G Jewett… - American Journal …, 2021 - Am Soc Neuroradiology
BACKGROUND: Balloon guide catheters are increasingly used to improve clot retrieval by
temporarily stopping proximal blood flow during endovascular thrombectomy. PURPOSE …
temporarily stopping proximal blood flow during endovascular thrombectomy. PURPOSE …
Balloon guide catheter is not superior to conventional guide catheter when stent retriever and contact aspiration are combined for stroke treatment
BACKGROUND The effectiveness of balloon guide catheter (BGC) use has not been
prospectively studied and its added value for improving reperfusion in acute ischemic stroke …
prospectively studied and its added value for improving reperfusion in acute ischemic stroke …
Cervical internal carotid artery tortuosity: A morphologic analysis of patients with acute ischemic stroke
JC Benson, W Brinjikji, SA Messina… - Interventional …, 2020 - journals.sagepub.com
Background and purpose Cervical internal carotid artery (ICA) tortuosity is thought to impede
distal catheterization during attempted mechanical thrombectomy in patients with acute …
distal catheterization during attempted mechanical thrombectomy in patients with acute …
[HTML][HTML] Predictors of successful first-pass thrombectomy with a balloon guide catheter: results of a decision tree analysis
A Velasco Gonzalez, D Görlich, B Buerke… - Translational stroke …, 2020 - Springer
Complete recanalization after a single retrieval maneuver is an interventional goal in acute
ischemic stroke and an independent factor for good clinical outcome. Anatomical biomarkers …
ischemic stroke and an independent factor for good clinical outcome. Anatomical biomarkers …
Comparative study of intracranial access in thrombectomy using next generation 0.088 inch guide catheter technology
DV Bageac, BS Gershon, J Vargas, M Mokin… - Journal of …, 2022 - jnis.bmj.com
Background Most conventional 0.088 inch guide catheters cannot safely navigate
intracranial vasculature. The objective of this study is to evaluate the safety of stroke …
intracranial vasculature. The objective of this study is to evaluate the safety of stroke …
Balloon gliding technique: a novel use of balloon guiding catheters in accessing challenging circulations when treating acute ischemic stroke
M Abdalkader, A Sahoo, J Lee, N Kiley… - Interventional …, 2023 - journals.sagepub.com
Background Challenging arterial anatomy delays, or prevents timely endovascular treatment
(EVT) of acute ischemic stroke (AIS). We introduce a new technique called 'Balloon Gliding …
(EVT) of acute ischemic stroke (AIS). We introduce a new technique called 'Balloon Gliding …
Clot meniscus sign: an angiographic clue for choosing between stent retriever and contact aspiration in acute basilar artery occlusion
SH Baik, C Jung, BM Kim, K Han… - American Journal of …, 2021 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: The efficacy of mechanical thrombectomy methods may
differ depending on the characteristics of the occlusion. The purpose of this study was to …
differ depending on the characteristics of the occlusion. The purpose of this study was to …
Distal placement of balloon guide catheter facilitates stent-retriever mechanical thrombectomy for acute ischemic stroke in the anterior circulation
IH Lee, SK Ha, DJ Lim, JI Choi - Acta Neurochirurgica, 2023 - Springer
Purpose Although balloon guide catheters (BGCs) have been demonstrated to improve
recanalization and functional outcomes by enabling proximal flow control and forced …
recanalization and functional outcomes by enabling proximal flow control and forced …
[HTML][HTML] First experience with Walrus balloon guide catheter in a whole-body flow model
H Guerreiro, FA Flottmann, AA Kyselyova, M Wagner… - Neuroradiology, 2023 - Springer
Purpose Flow arrest using a balloon guide catheter (BGC) in mechanical thrombectomy
(MT) due to large vessel occlusion has been associated with better outcomes. Known …
(MT) due to large vessel occlusion has been associated with better outcomes. Known …