Safety considerations in MR imaging.
E Kanal, FG Shellock, L Talagala - Radiology, 1990 - pubs.rsna.org
The authors identify eight areas of potential safety concern during clinical magnetic
resonance (MR) imaging. These include (a) biologic effects of the static magnetic field;(b) …
resonance (MR) imaging. These include (a) biologic effects of the static magnetic field;(b) …
Safety issues in magnetic resonance imaging
SM Chung - Journal of neuro-ophthalmology, 2002 - journals.lww.com
Although generally considered safe, magnetic resonance imaging (MRI) has a number of
safety issues, including the effects of high magnetic fields and radiofrequency pulses on the …
safety issues, including the effects of high magnetic fields and radiofrequency pulses on the …
The role of MR angiography in the pretreatment assessment of intracranial aneurysms: a comparative study
WM Adams, RD Laitt, A Jackson - American Journal of …, 2000 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: With developments in coil technology, intracranial
aneurysms are being treated increasingly by the endovascular route. Endovascular …
aneurysms are being treated increasingly by the endovascular route. Endovascular …
MR imaging after aneurysmal subarachnoid hemorrhage and surgery: a long-term follow-up study
RP Kivisaari, O Salonen, A Servo… - American Journal …, 2001 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: We assumed that patients with surgically treated
aneurysmal subarachnoid hemorrhage (SAH) might have more lesions than those revealed …
aneurysmal subarachnoid hemorrhage (SAH) might have more lesions than those revealed …
Simulation of susceptibility artifacts in 2D and 3D Fourier transform spin-echo and gradient-echo magnetic resonance imaging
CJG Bakker, R Bhagwandien, MA Moerland… - Magnetic resonance …, 1994 - Elsevier
A method is presented for simulating susceptibility artifacts in 2D and 3D spin-echo and
gradient-echo imaging of arbitrary susceptibility distributions. The method incorporates …
gradient-echo imaging of arbitrary susceptibility distributions. The method incorporates …
Basal brain injury in aneurysm surgery
RP Kivisaari, O Salonen, J Öhman - Neurosurgery, 2000 - journals.lww.com
OBJECTIVE: The goal of this study was to determine the frequency of lesions in the basal
frontotemporal area that were related to surgical damage to the brain tissue. METHODS: A …
frontotemporal area that were related to surgical damage to the brain tissue. METHODS: A …
Magnetic resonance angiography with ultrashort echo times reduces the artefact of aneurysm clips
F Gönner, K Lövblad, O Heid, L Remonda, R Guzman… - Neuroradiology, 2002 - Springer
We evaluated the ability of an ultrashort echo time (TE) three-dimensional (3D) time-of-flight
(TOF) magnetic resonance angiography (MRA) sequence to reduce the metal artefact of …
(TOF) magnetic resonance angiography (MRA) sequence to reduce the metal artefact of …
CT angiography in the examination of patients with aneurysm clips.
PT Vieco, EE Morin, CE Gross - American journal of …, 1996 - Am Soc Neuroradiology
The use of CT angiography is described in three patients for the evaluation of intracranial
clips after surgery for an aneurysm. A postprocessing technique is described in which …
clips after surgery for an aneurysm. A postprocessing technique is described in which …
Aneurysm clip MR artifacts: titanium versus stainless steel and influence of imaging parameters
IM Burtscher, T Owman, B Romner, F Ståhlberg… - Acta …, 1998 - Taylor & Francis
Purpose: the aim of this study was to evaluate the extent to which titanium aneurysm clips
could improve the quality of MR imaging compared with stainless steel clips, and to …
could improve the quality of MR imaging compared with stainless steel clips, and to …
Aneurysm clip testing for ferromagnetic properties: clip variability issues.
E Kanal, FG Shellock, JS Lewin - Radiology, 1996 - pubs.rsna.org
To assess ferromagnetic properties of intracranial aneurysm clips reported to be
nonferromagnetic, 1,765 Yasargil, 11 Sugita, and 15 Perneczky aneurysm clips were …
nonferromagnetic, 1,765 Yasargil, 11 Sugita, and 15 Perneczky aneurysm clips were …