Normal pituitary stalk: high-resolution MR imaging at 3T

N Satogami, Y Miki, T Koyama… - American journal of …, 2010 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Knowing the normal imaging appearance of the pituitary
stalk is important for the diagnosis of pituitary infundibular lesions, and more accurate …

Three-dimensional magnetic resonance-based morphometry of pituitary stalk

V Raveendranath, K Nagarajan, A Umamageswari… - La radiologia …, 2019 - Springer
Purpose The pituitary or infundibular stalk is an anatomically important structure identified
routinely in radiologic imaging for the evaluation of pituitary and suprasellar lesions. The …

MR imaging of the pituitary stalk: size, shape, and enhancement pattern.

GE Simmons, JE Suchnicki, KM Rak… - … . American journal of …, 1992 - Am Roentgen Ray Soc
The size, shape, signal intensity, and enhancement pattern of the normal pituitary stalk were
determined retrospectively by review of MR images of 58 patients. The pituitary stalk was …

Pituitary stalk lesions: the Mayo Clinic experience

AF Turcu, BJ Erickson, E Lin, S Guadalix… - The Journal of …, 2013 - academic.oup.com
Context: Pituitary stalk lesions have various etiologies, often not clinically apparent.
Pathological samples from these lesions are rarely obtained, because of the critical location …

Normal dimensions of the posterior pituitary bright spot on magnetic resonance imaging

M Côté, KL SaLzMan, M Sorour, WT Couldwell - Journal of Neurosurgery, 2014 - thejns.org
Object The normal pituitary bright spot seen on unenhanced T1-weighted MRI is thought to
result from the T1-shortening effect of the vasopressin stored in the posterior pituitary …

Imaging of the pituitary and parasellar region

CS Zee, JL Go, PE Kim, D Mitchell… - Neurosurgery …, 2003 - neurosurgery.theclinics.com
The pituitary gland sits in the bony pituitary fossa, which is superior to the sphenoid sinus.
The pituitary gland is an oblong structure that measures approximately 12 mm transversely …

Role of MRI T2-DRIVE in the assessment of pituitary stalk abnormalities without gadolinium in pituitary diseases

E Godano, G Morana, N Di Iorgi… - European journal of …, 2018 - academic.oup.com
Objective To investigate the role of T2-DRIVE MRI sequence in the accurate measurement
of pituitary stalk (PS) size and the identification of PS abnormalities in patients with …

Correlation of high signal intensity of the pituitary stalk in macroadenoma and postoperative diabetes insipidus

N Saeki, S Hoshi, S Sunada… - American journal …, 2002 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: High signal intensity (HSI) at the pituitary stalk is reported
in pituitary adenomas. Our purpose was to clarify how and when this HSI formed, its long …

Imaging of the pituitary

T Ouyang, WE Rothfus, JM Ng… - Radiologic …, 2011 - radiologic.theclinics.com
Since the advent of magnetic resonance (MR) imaging, imaging has become an integral part
of the evaluation of patients with endocrinological abnormalities suspected to be of pituitary …

Tumor T2 signal intensity and stalk angulation correlates with endocrine status in pituitary adenoma patients: a quantitative 7 tesla MRI study

JW Rutland, P Pawha, P Belani, BN Delman, CM Gill… - Neuroradiology, 2020 - Springer
Purpose Pituitary adenomas are common CNS tumors that can cause endocrine dysfunction
due to hormone oversecretion and by mass effect on the normal gland. The study of pituitary …