Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Publication Preview--Ahead of Print
    • Past Issue Archive
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
    • COVID-19 Content and Resources
  • For Authors
    • Author Policies
    • Manuscript Submission Guidelines
  • About Us
    • About AJNR
    • American Society of Neuroradiology
  • Submit a Manuscript
  • Podcasts
    • Podcasts
    • Subscribe on iTunes
  • More
    • Subscribers
    • Permissions
    • Advertisers
    • Alerts
    • Feedback

User menu

  • Subscribe
  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

  • Subscribe
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Publication Preview--Ahead of Print
    • Past Issue Archive
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
    • COVID-19 Content and Resources
  • For Authors
    • Author Policies
    • Manuscript Submission Guidelines
  • About Us
    • About AJNR
    • American Society of Neuroradiology
  • Submit a Manuscript
  • Podcasts
    • Podcasts
    • Subscribe on iTunes
  • More
    • Subscribers
    • Permissions
    • Advertisers
    • Alerts
    • Feedback
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds
Abstract

Flow-Controlled Therapeutic Embolization: A Physiologic and Safe Technique

Charles W. Kerber
American Journal of Neuroradiology January 1980, 1 (1) 77-81;
Charles W. Kerber
1Department of Radiology, Presbyterian-University Hospital, DeSoto at O'Hara St., Pittsburgh, PA 15213
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • PDF
Loading

Abstract

A feared complication of therapeutic embolization is loss of control of one or more particles with resultant ischemic infarction of normal tissues. To avoid passage of emboli into normal arteries, the delivery catheter may be wedged tightly into the artery or the artery completely occluded with a balloon catheter during embolus injection. These techniques, termed occlusion control, were a valuable forward step and significantly enhanced patient safety. However, occluding the vessel completely may cause spasm, and allows the operator to introduce fluid and emboli under higher than normal perfusion pressures which can open extra- to intracranial shunts and cause disastrous intracranial embolization.

A further refinement is suggested. First, the emboli are suspended in contrast agent; then the particles are introduced while arterial runoff of the contrast agent is watched so the acceptance rate of the artery is not exceeded. Normal perfusion pressures and flow then carry the embolus distally into the abnormality being treated. This technique is safe, easily learned, and gives the radiologist direct vision control over the embolization process. It has been used in 39 patients with only one serious complication.

  • © American Roentgen Ray Society
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology
Vol. 1, Issue 1
1 Jan 1980
  • Table of Contents
  • Index by author
Advertisement
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Flow-Controlled Therapeutic Embolization: A Physiologic and Safe Technique
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Flow-Controlled Therapeutic Embolization: A Physiologic and Safe Technique
Charles W. Kerber
American Journal of Neuroradiology Jan 1980, 1 (1) 77-81;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Flow-Controlled Therapeutic Embolization: A Physiologic and Safe Technique
Charles W. Kerber
American Journal of Neuroradiology Jan 1980, 1 (1) 77-81;
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

Similar Articles

Advertisement

News and Updates

  • Lucien Levy Best Research Article Award
  • Thanks to our 2022 Distinguished Reviewers

Resources

  • Evidence-Based Medicine Level Guide
  • AJNR Podcast Archive
  • Librarian Resources
  • Terms and Conditions

Opportunities

  • Get Peer Review Credit from Publons

American Society of Neuroradiology

  • Neurographics
  • ASNR Annual Meeting
  • Fellowship Portal

© 2023 by the American Society of Neuroradiology | Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire