OtherSPINE
Intraspinal Leakage of Bone Cement after Vertebroplasty: A Report of 3 Cases
M.M.H. Teng, H. Cheng, D.M.-T. Ho and C.-Y. Chang
American Journal of Neuroradiology January 2006, 27 (1) 224-229;
M.M.H. Teng
H. Cheng
D.M.-T. Ho
References
- ↵Galibert P, Deramond H, Rosat P, et al. Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty. Neurochirugie 1987;33:166–68 [in French]
- ↵Cotten A, Dewatre F, Cortet B, et al. Percutaneous vertebroplasty for osteolytic metastases and myeloma: effects of the percentage of lesion filling and the leakage of methyl methacrylate at clinical follow-up. Radiology 1996;200:525–30
- Deramond H, Depriester C, Galibert P, et al. Percutaneous vertebroplasty with polymethylmethacrylate. Technique, indications, and results. Radiol Clin North Am 1998;36:533–46
- ↵Jensen ME, Evans AJ, Mathis JM, et al. Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: technical aspects. AJNR Am J Neuroradiol 1997;18:1897–1904
- ↵Harrington KD. Major neurological complications following percutaneous vertebroplasty with polymethylmethacrylate: a case report. J Bone Joint Surg 2001;83-A:1070–73
- ↵
- Amar AP, Larsen DW, Esnaashari N, et al. Percutaneous transpedicular polymethylmethacrylate vertebroplasty for the treatment of spinal compression fractures. Neurosurgery 2001;49:1105–14
- ↵
- ↵Chen LH, Niu CC, Yu SW, et al. Minimally invasive treatment of osteoporotic vertebral compression fracture. Chang Gung Med J 2004;27:261–67
- ↵Ryu KS, Park CK, Kim MC, et al. Dose-dependent epidural leakage of polymethylmethacrylate after percutaneous vertebroplasty in patients with osteoporotic vertebral compression fractures. J Neurosurg 2002;96(1 suppl):56–61
- ↵Gaughen JR Jr, Jensen ME, Schweickert PA, et al. Relevance of antecedent venography in percutaneous vertebroplasty for the treatment of osteoporotic compression fractures. AJNR Am J Neuroradiol 2002;23:594–600
- ↵Cotten A, Boutry N, Cortet B, et al. Percutaneous vertebroplasty: state of the art. Radiographics 1998;18:311–20
- ↵Garfin SR, Reilley MA. Minimally invasive treatment of osteoporotic vertebral body compression fracture. Spine J 2000;2:76–80
- ↵Grados F, Depriester C, Cayrolle G. Long-term observations of vertebral osteoporotic fractures treated by percutaneous vertebroplasty. Rheumatology 2000;39:1410–14
- ↵Belkoff SM, Molloy S. Temperature measurement during polymerization of polymethylmethacrylate cement used for vertebroplasty. Spine 2003;28:1555–59
In this issue
Advertisement
Intraspinal Leakage of Bone Cement after Vertebroplasty: A Report of 3 Cases
M.M.H. Teng, H. Cheng, D.M.-T. Ho, C.-Y. Chang
American Journal of Neuroradiology Jan 2006, 27 (1) 224-229;
Jump to section
Related Articles
- No related articles found.
Cited By...
- Large intraspinal cement leak during multilevel cement-augmented screw fixation
- Pulmonary embolism with coexistent incidental pulmonary cement embolism post vertebroplasty
- Sacral bone cyst treatment resulting in paraplegia
- Use and evaluation of a semi-permeable mesh implant in vertebral augmentation for the treatment of painful osteoporotic vertebral compression fractures
This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.
More in this TOC Section
Similar Articles
Advertisement