Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Publication Preview--Ahead of Print
    • Past Issue Archive
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
    • COVID-19 Content and Resources
  • For Authors
  • About Us
    • About AJNR
    • Editors
    • American Society of Neuroradiology
  • Submit a Manuscript
  • Podcasts
    • Subscribe on iTunes
    • Subscribe on Stitcher
  • More
    • Subscribers
    • Permissions
    • Advertisers
    • Alerts
    • Feedback
  • Other Publications
    • ajnr

User menu

  • Subscribe
  • Alerts
  • Log in
  • Log out

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

  • Subscribe
  • Alerts
  • Log in
  • Log out

Advanced Search

  • Home
  • Content
    • Current Issue
    • Publication Preview--Ahead of Print
    • Past Issue Archive
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
    • COVID-19 Content and Resources
  • For Authors
  • About Us
    • About AJNR
    • Editors
    • American Society of Neuroradiology
  • Submit a Manuscript
  • Podcasts
    • Subscribe on iTunes
    • Subscribe on Stitcher
  • More
    • Subscribers
    • Permissions
    • Advertisers
    • Alerts
    • Feedback
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds
Research ArticleSPINE

Gadolinium Use in Spine Procedures for Patients with Allergy to Iodinated Contrast—Experience of 127 Procedures

Y. Safriel, M. Ali, M. Hayt and R. Ang
American Journal of Neuroradiology June 2006, 27 (6) 1194-1197;
Y. Safriel
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
M. Ali
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
M. Hayt
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
R. Ang
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • References
  • PDF
Loading

Abstract

BACKGROUND AND PURPOSE: To review the safety and efficacy of gadolinium as a contrast agent in spine pain management procedures in patients who are at high risk for a contrast reaction and are therefore unacceptable candidates for the use of standard nonionic contrast.

METHODS: We reviewed our records over a 4-year period of interlaminar and foraminal epidural steroid injections, nerve blocks, facet injections, intercostal blocks, and diskograms in the lumbar, thoracic, and cervical spine for cases in which patients had allergies that made them unsuitable candidates for standard nonionic contrast and where gadolinium was used to confirm needle tip placement before injection of medication.

RESULTS: Ninety-two patients underwent 127 procedures. A spinal needle was used in all but 7 procedures. All patients were outpatients and all were discharged without complication after 20 to 45 minutes with follow-up instructions. No delayed complications were reported. Gadolinium was visualized by using portable C-arm fluoroscopy in vivo allowing for confirmation of needle tip location. For epidural steroid injection, the gadolinium dose ranged from 1 to 5 mL, nerve blocks from 0.2 to 1 mL per level, facet injections from 0.2 to 0.5 mL per level, intercostal blocks used 0.5 mL, and diskograms from 1.5 to 7.5 mL per level. The highest dose received by 1 patient was an intradiskal 15.83 mL during a 3-level diskogram.

CONCLUSION: Gadolinium seems to be a safe alternative to standard nonionic contrast in spine pain management procedures in those patients considered to be at high risk for a contrast reaction.

The use of epidural injections for the treatment of back pain was first described by Evans in 1930.1 Since then, a growing body of evidence has documented the need for fluoroscopic confirmation of needle placement2,3 by using x-ray attenuating contrast. Most commonly, this involves nonionic contrast. A small but significant group of patients exhibit allergic symptoms to contrast. Contrast reactions have been documented in the setting of vascular injections. A vascular injection is a recognized complication of spinal pain management procedures.2 Vascular injections should be avoided because they may result in injection of particulate steroid and local anesthetic to the systemic circulation with possible embolic effects and arrhythmias, respectively. In a series by Katayama et al,4 adverse drug reaction with the intravenous use of nonionic contrast was noted at 1.2% to 3.13%, of which 0.02% to 0.04% were severe. Therefore, some patients should not receive iodinated ionic or nonionic contrast. Another common potential complication of epidural injections is inadvertent intrathecal injections. This carries a risk of spinal anesthesia with subsequent hypotension in patients who may have limited cardiovascular reserve as well as adhesive arachnoiditis induced by some classes of steroids.5,6 Very little work has been published in the literature regarding the use of gadolinium in the intrathecal space7,8 because there are few clinical applications. As needle misplacement is the most common complication of percutaneous spinal injections, it is essential to use a contrast agent to determine the exact position of the needle tip in all patients. We therefore present our collective findings on the use of gadolinium as an effective contrast agent in percutaneous outpatient image-guided spine procedures demonstrating it as a safe alternative in those patients who are otherwise not candidates for contrast use.

Materials and Methods

We performed a retrospective record search in our computerized data system from 2001 to 2004 (4 years) of our records of percutaneous outpatient spinal interventions. The search included all interlaminar and foraminal epidural steroid injections, nerve blocks, facet injections, intercostal blocks, and diskograms in the lumbar, thoracic, and cervical spine where gadolinium/gadodiamide (Omniscan; GE Healthcare, Little Chalfont, Buckinghamshire, UK) was used. Gadolinium was used for needle tip location confirmation in cases where contraindications existed to the routine use of iohexol 240 (Omnipaque; GE Healthcare). Contraindications to iodinated contrasts were defined as a documented history of adverse reactions after injection of iodinated contrast media, patients in or with a history of renal failure, diabetics with increased creatinine levels as determined by the reference ranges at the local laboratory, and patients taking metformin (Glucophage) or glyburide/metformin (Glucovance) who had taken their medication in the 48 hours leading up to the procedure.

All procedures were performed on an outpatient basis using portable C-arm fluoroscopy (OEC 9600 or OEC 9800; General Electric, Milwaukee, Wis). The patients signed informed consent for the procedure and were given the alternatives of rescheduling the procedure after steroid premedication, the use of saline or air in place of contrast, or aborting the procedure. All procedures were performed as part of routine clinical care and not as part of a research study. As is the clinical routine in our facility, all patients were observed for at least 30 minutes after the procedure and were given standard instructions to call the radiologist on call in the event of an adverse reaction. The procedures were performed under sterile conditions with the patient taking nothing by mouth between 1 and 4 hours before the start. Under fluoroscopic guidance, a spinal needle (or, in some cases in the cervical spine, a Whitacre needle) was guided into position. The gadolinium was drawn into a syringe (5 or 10 mL) from a 20-mL container that had been opened for less than 24 hours and stored in a dark cupboard at temperatures between 15 and 30°C according to the manufacturer’s recommendations. A gadolinium test injection was then performed to confirm correct location of the needle and to exclude vascular or intrathecal injection. The procedure was performed, at the discretion of the operator, by using local anesthesia but without conscious sedation. After needle localization, depending on the procedure type, the patients were administered with a combination of steroid and local anesthetic, steroid alone or, in the case of diskograms after pain response was determined, local anesthetic only.

Results

We identified 92 patients who underwent 127 procedures. Table 1 provides a breakdown of the type of procedures and contrast amounts. A spinal needle was used in 120 procedures. The remaining procedures used a Whitacre needle. All patients were outpatients and all were discharged without complication after 20 to 45 minutes. No delayed complications were reported. Gadolinium was visualized by using portable C-arm fluoroscopy in vivo allowing for confirmation of needle tip location and excluding vascular or intrathecal location.

View this table:
  • View inline
  • View popup
Table 1:

Procedure type, location, and contrast amounts

Although gadodiamide was less conspicuous than iohexol 240, there was sufficient visualization of the contrast material (Figs 1, 2, and 3). For epidural steroid injections, gadodiamide dose ranged from 1 to 5 mL, nerve blocks from 0.2 to 1 mL per level, facet injections from 0.2 to 0.5 mL per level, intercostal blocks used 0.5 mL, and diskograms used from 1.5 to 7.5 mL per level. The highest dose received by a single patient was an intradiskal 15.83 mL during a 3-level diskogram.

Fig 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 1.

Visualization of iohexol 240 and gadodiamide using fluoroscopy. 5 mL of iohexol 240 (Omnipaque; left) and gadodiamide (Omniscan; right) were drawn into a 5-mL syringe and a snapshot image was obtained with the use of a portable C-arm (GE 9600) at 0.6 mA and 46 Kv.

Fig 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 2.

Cervical interlaminar epidurography using gadodiamide (a) and iohexol 240 (b).

Fig 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 3.

Lumbar interlaminar epidurography using gadodiamide (a) and iohexol 240 (b).

Discussion

Degenerative back disease is a growing health care problem as the number of aged patients increases. Furthermore, there is a growing trend to use percutaneous image-guided spinal interventions to alleviate or palliate pain9,10 and as a prelude to surgery both in determining whether surgery is necessary and in determining the operative levels.11,12 To date, however, no article in the medical literature guides physicians in the use of gadolinium in the event a patient is considered an unsuitable candidate for iodinated contrast in image-guided spinal procedures. As part of the informed consent process required for such procedures, one of the basic tenets is giving the patient a complete overview of the risks and benefits. This article addresses that gap in the literature.

There is a significant body of evidence attesting to the safety of gadolinium compounds injected intravenously, with doses as high as 60 mL for CT angiography13 and for MR studies.14–16 No overdose of gadodiamide has been reported.17 Mild-to-moderate side effects occurred in less than 1% of patients when administered intravenously.18–23 Nausea or vomiting and headache are the most common adverse effects, with a frequency ranging from 0.26% to 0.42%.20 Other rare reactions reported after the IV administration of gadolinium products include paresthesias, dizziness, focal convulsions, urticaria, mucosal reactions, generalized flushing, cardiovascular reactions (eg, tachycardia, arrhythmia), generalized seizures, laryngospasm, and anaphylactic shock.18–23 A study in an animal model that used low intrathecal doses of gadolinium did not reveal such alterations.24 A large multicenter study of 95 patients showed no deleterious effects of up to 5 mL of a gadolinium compound (Magnevist; Schering, Berlin, Germany) injected into the lumbar subarachnoid space,8 whereas another study demonstrated safety of gadolinium injected directly into the ventricles.25

Although our study did not include a formal control group, as suggested by Johnson,26 the practice of epidural spinal injections is now so widely entrenched in routine clinical medicine that there is no need for a formal control group. The risks and complications of image-guided spinal procedures using iodinated contrast have been published by members of our group as well as others and have been well documented.2,9,10 Between the authors of this article (excluding the authors’ partners/colleagues), we perform approximately 60 such procedures per day with iohexol 240. Interpolating that to the thousands of physiatrists and pain specialists in the United States, innumerable instances of these procedures are performed daily. Therefore, the “control” is the routine standard of care. Furthermore, our injection techniques are identical to those in the original article by our colleagues, who reviewed 5334 cases2 and that are currently the standard of care with a known and accepted safety profile.

We used gadodiamide because it was the gadolinium preparation available in our institutions. We recognize that there are several other widely available gadolinium-based contrast agents that are often used interchangeably in clinical practice. Therefore, our study is strictly applicable only to gadodiamide (Omniscan). Future larger studies may also include other gadolinium agents.

We chose to include all image-guided pain management procedures for this study because the potential for intrathecal or intravenous administration exists with all procedures. A previous series of gadolinium diskography used gadopentetate dimeglumine (Magnevist; Schering) at low concentrations (1:250) for MR diskography.27 For this unusual application of diskography, such low doses suffice. However, for routine diskography and other percutaneous spine interventions, such low doses would not attenuate the x-ray beam sufficiently to be visualized; therefore, higher doses would have to be used.

The importance of defining the exact position of the needle tip cannot be understated and is difficult to achieve without some form of contrast injection.3 The main danger in imprecise needle position is intrathecal administration of injectate, which may result in steroid-induced adhesive arachnoiditis and anesthetic-induced spinal anesthesia, which can cause hypotension.5,6 Vascular injection may result in particulate steroid material entering and embolizing in the circulation and arrhythmias because of vascular local anesthesia. The only method of confirming nonvascular location is via a contrast injection, because saline and/or air would not opacify the small perispinal vessels.2 In the end, even if blind needle placement does not result in an adverse event, it has been shown that a blind approach does not result in correct placement of therapeutic material2,3,28,29 in up to 30% of instances. Although this may not hurt the patient, it would not benefit them either and would result in an essentially ineffective procedure for which the patient was charged a fee. Therefore, contrast injection in the performance of image-guided spinal interventions is a necessity and not a luxury.

Conclusion

Gadolinium seems to be a safe alternative to iodinated contrast for percutaneous image guided outpatient procedures in patients who are deemed unsuitable candidates for the use of iodinated contrast.

Author’s Note

Since the submission of our original paper, the authors have amassed an additional 400 procedures. In this larger cohort, we had one documented inadvertent intrathecal injection in the lumbar spine, without complication. One patient undergoing cervical interlaminar epidurography and another undergoing a two level cervical diskogram on the same day experienced an adverse event that included seizures and necessitated ICU admission. Both patients were discharged without complications after 3 days. Because both reactions happened at the same center within an hour of each other, because both procedures were at the hand of a very experienced radiologist, and because these were the only adverse events in the entire study, we cannot exclude the possibility that the gadolinium batch was tainted. Based on our wider experience, we think that gadolinium is safe for use in the lumbar spine. The indication for gadolinium use in cervical needle-guided spine procedures are less clear, and use of a blunt-tip needle should be considered. These patients, as well as the rest of our larger cohort, will be the subject of a follow-up paper.

Acknowledgments

The authors are grateful to Tamara Frink, Center for Diagnostic Imaging, St. Cloud, Minn, for her assistance in preparing this manuscript.

References

  1. ↵
    Evans W. Intrasacral epidural injection therapy in the treatment of sciatica. Lancet 1930;2:1225–29
  2. ↵
    Johnson BA, Schellhas KP, Pollei SR, et al. Epidurography and therapeutic epidural injections: technical considerations and experience with 5334 cases. AJNR Am J Neuroradiol 1999;20:697–705
    Abstract/FREE Full Text
  3. ↵
    Bartynski WS, Grahovac SZ, Rothfus WE. Incorrect needle position during lumbar epidural steroid administration: inaccuracy of loss of air pressure resistance and requirement of fluoroscopy and epidurography during needle insertion. AJNR Am J Neuroradiol 2005;26:502–05
    Abstract/FREE Full Text
  4. ↵
    Katayama H, Yamaguchi K, Kozuka T, et al. Adverse reactions to ionic and nonionic contrast media. A report from the Japanese Committee on the Safety of Contrast Media. Radiology 1990;175:621–28
    CrossRefPubMed
  5. ↵
    Abram SE, O’Connor TC. Complications associated with epidural steroid injections. Reg Anesth 1996;21:149–62
    PubMed
  6. ↵
    Nelson DA. Intraspinal therapy using methylprednisolone acetate: twenty-three years of clinical controversy. Spine 1993;18:278–86
    PubMed
  7. ↵
    Skalpe IO. Is it dangerous to inject magnetic resonance contrast media into the subarachnoid space? Eur Radiol 1998;8:427
    PubMed
  8. ↵
    Tali ET, Ercan N, Krumina G, et al. Intrathecal gadolinium (gadopentetate dimeglumine) enhanced magnetic resonance myelography and cisternography: results of a multicenter study. Invest Radiol 2002;37:152–59
    CrossRefPubMed
  9. ↵
    Botwin KP, Gruber RD, Bouchlas CG, et al. Fluoroscopically guided lumbar transformational epidural steroid injections in degenerative lumbar stenosis: an outcome study. Am J Phys Med Rehabil 2002;81:898–905
    CrossRefPubMed
  10. ↵
    Lynch MC, and Taylor JF. Facet joint injection for low back pain. A clinical study. J Bone Joint Surg Br 1986;68:138–41
    PubMed
  11. ↵
    Riew KD, Yin Y, Gilula L, et al. The effect of nerve-root injections on the need for operative treatment of lumbar radicular pain. A prospective, randomized, controlled, double-blind study. J Bone Joint Surg Am 2000;82:1589–93
    PubMed
  12. ↵
    Kaplan M, Dreyfuss P, Halbrook B, et al. The ability of lumbar medial branch blocks to anesthetize the zygapophysial joint. A physiologic challenge. Spine 1998;23:1847–52
    CrossRefPubMed
  13. ↵
    Henson JW, Nogueira RG, Covarrubias DJ, et la. Gadolinium-enhanced CT angiography of the circle of Willis and neck. AJNR Am J Neuroradiol 2004;25:969–72
    Abstract/FREE Full Text
  14. ↵
    Filippi M, Rovaris M, Capra R, et al. A multi-centre longitudinal study comparing the sensitivity of monthly MRI after standard and triple dose gadolinium-DTPA for monitoring disease activity in multiple sclerosis. Implications for phase II clinical trials. Brain 1998;121:2011–20
    Abstract/FREE Full Text
  15. Yousry I, Filippi M, Walther E, et al. Serial gadolinium-DTPA of spinal cord MRI in multiple sclerosis: triple vs. single dose. Magn Reson Imaging 2000;18:1183–86
    PubMed
  16. ↵
    Okada S, Katagiri K, Kumazaki T, et al. Safety of gadolinium contrast agent in hemodialysis patients. Acta Radiol 2001;42:339–41
    FREE Full Text
  17. ↵
    Omniscan [package insert]. Little Chalfont, Buckinghamshire, UK: GE Healthcare;2005
  18. ↵
    Niendorf HP, Haustein J, Cornelius I, et al. Safety of gadolinium-DTPA: extended clinical experience. Mag Reson Med 1991;22:222–28
    PubMed
  19. Niendorf HP, Haustein J, Louton T, et al. Safety and tolerance after intravenous administration of 0.3 mmol/kg Gd-DTPA: results of a randomized, controlled clinical trial. Invest Radiol 1991;26:S221–S223
    PubMed
  20. ↵
    Goldstein HA, Kashanian FK, Blumetti RF, et al. Safety assessment of gadopentetate dimeglumine in US clinical trials. Radiology 1990;174:17–23
    PubMed
  21. Tardy B, Guy C, Barral G, et al. Anaphylactic shock induced by intravenous gadopentetate dimeglumine. Lancet 1992;339:494
    PubMed
  22. Harbury OL. Generalized seizure after IV administration of gadopentetate dimeglumine. AJNR Am J Neuroradiol 1991;12:666
    FREE Full Text
  23. ↵
    Tishler S, Hoffman JC Jr. Anaphylactoid reactions to IV gadopentetate dimeglumine. AJNR Am J Neuroradiol 1990;11:1167
    FREE Full Text
  24. ↵
    Skalpe IO, Tang GJ. Magnetic resonance imaging contrast media in the subarachnoid space. A comparison between gadodiamide injection and gadopentetate dimeglumine in an experimental study in pigs. Invest Radiol 1997;32:140–48
    CrossRefPubMed
  25. ↵
    Siebner HR, Grafin von Einsiedel H, Conrad B. Magnetic resonance ventriculography with gadolinium DTPA: report of two cases. Neuroradiology 1997;39:418–22
    CrossRefPubMed
  26. ↵
    Johnson DW. Back to the future: epidurography. AJNR Am J Neuroradiol 1998;20:537
  27. ↵
    Wagner AL. Gadolinium diskography. AJNR Am J Neuroradiol 2004;25:1824–27
    Abstract/FREE Full Text
  28. ↵
    Renfrew DL, Moore TE, Kathol MH, et al. Correct placement of epidural steroid injections: fluoroscopic guidance and contrast administration. AJNR Am J Neuroradiol 1991;12:1003–07
    Abstract/FREE Full Text
  29. ↵
    White AH, Derby R, Wynne G. Epidural injections for the diagnosis and treatment of low-back pain. Spine 1980;5:78–86
    CrossRefPubMed
  • Received July 14, 2005.
  • Accepted after revision November 1, 2005.
  • Copyright © American Society of Neuroradiology
View Abstract
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 27 (6)
American Journal of Neuroradiology
Vol. 27, Issue 6
June 2006
  • Table of Contents
  • Index by author
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Gadolinium Use in Spine Procedures for Patients with Allergy to Iodinated Contrast—Experience of 127 Procedures
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Gadolinium Use in Spine Procedures for Patients with Allergy to Iodinated Contrast—Experience of 127 Procedures
Y. Safriel, M. Ali, M. Hayt, R. Ang
American Journal of Neuroradiology Jun 2006, 27 (6) 1194-1197;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Gadolinium Use in Spine Procedures for Patients with Allergy to Iodinated Contrast—Experience of 127 Procedures
Y. Safriel, M. Ali, M. Hayt, R. Ang
American Journal of Neuroradiology Jun 2006, 27 (6) 1194-1197;
Reddit logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Materials and Methods
    • Results
    • Discussion
    • Conclusion
    • Author’s Note
    • Acknowledgments
    • References
  • Figures & Data
  • Info & Metrics
  • References
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Fatal gadolinium-induced encephalopathy following accidental intrathecal administration: a case report and a comprehensive evidence-based review
  • Safety of 1000 CT-Guided Steroid Injections with Air Used to Localize the Epidural Space
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

More in this TOC Section

  • Conebeam CT as an Adjunct to Digital Subtraction Myelography for Detection of CSF-Venous Fistulas
  • Postoperative Lumbar Fusion Bone Morphogenic Protein–Related Epidural Cyst Formation
  • Modified Dynamic CT Myelography for Type 1 and 2 CSF Leaks: A Procedural Approach
Show more Spine

Similar Articles

Advertisement

News and Updates

  • Lucien Levy Best Research Article Award
  • Thanks to our 2022 Distinguished Reviewers
  • Press Releases

Resources

  • Evidence-Based Medicine Level Guide
  • How to Participate in a Tweet Chat
  • AJNR Podcast Archive
  • Ideas for Publicizing Your Research
  • Librarian Resources
  • Terms and Conditions

Opportunities

  • Share Your Art in Perspectives
  • Get Peer Review Credit from Publons
  • Moderate a Tweet Chat

American Society of Neuroradiology

  • Neurographics
  • ASNR Annual Meeting
  • Fellowship Portal
  • Position Statements

© 2023 by the American Society of Neuroradiology | Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire