Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Publication Preview--Ahead of Print
    • Past Issue Archive
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
    • COVID-19 Content and Resources
  • For Authors
  • About Us
    • About AJNR
    • Editors
    • American Society of Neuroradiology
  • Submit a Manuscript
  • Podcasts
    • Subscribe on iTunes
    • Subscribe on Stitcher
  • More
    • Subscribers
    • Permissions
    • Advertisers
    • Alerts
    • Feedback
  • Other Publications
    • ajnr

User menu

  • Subscribe
  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

  • Subscribe
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Publication Preview--Ahead of Print
    • Past Issue Archive
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
    • COVID-19 Content and Resources
  • For Authors
  • About Us
    • About AJNR
    • Editors
    • American Society of Neuroradiology
  • Submit a Manuscript
  • Podcasts
    • Subscribe on iTunes
    • Subscribe on Stitcher
  • More
    • Subscribers
    • Permissions
    • Advertisers
    • Alerts
    • Feedback
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds
Research ArticlePatient Safety

Image Quality and Radiation Dose of Dual-Energy CT of the Head and Neck Compared with a Standard 120-kVp Acquisition

A.M. Tawfik, J.M. Kerl, A.A. Razek, R.W. Bauer, N.E. Nour-Eldin, T.J. Vogl and M.G. Mack
American Journal of Neuroradiology December 2011, 32 (11) 1994-1999; DOI: https://doi.org/10.3174/ajnr.A2654
A.M. Tawfik
aFrom the Department of Diagnostic and Interventional Radiology (A.M.T., J.M.K., R.B., N.E.N.-E., T.J.V., M.G.M.), Johan Wolfgang Goethe University Hospital, Frankfurt am Main, Germany
bDepartment of Diagnostic Radiology (A.M.T., A.A.R.), Mansoura University, Mansoura City, Egypt
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
J.M. Kerl
aFrom the Department of Diagnostic and Interventional Radiology (A.M.T., J.M.K., R.B., N.E.N.-E., T.J.V., M.G.M.), Johan Wolfgang Goethe University Hospital, Frankfurt am Main, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
A.A. Razek
bDepartment of Diagnostic Radiology (A.M.T., A.A.R.), Mansoura University, Mansoura City, Egypt
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
R.W. Bauer
aFrom the Department of Diagnostic and Interventional Radiology (A.M.T., J.M.K., R.B., N.E.N.-E., T.J.V., M.G.M.), Johan Wolfgang Goethe University Hospital, Frankfurt am Main, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
N.E. Nour-Eldin
aFrom the Department of Diagnostic and Interventional Radiology (A.M.T., J.M.K., R.B., N.E.N.-E., T.J.V., M.G.M.), Johan Wolfgang Goethe University Hospital, Frankfurt am Main, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
T.J. Vogl
aFrom the Department of Diagnostic and Interventional Radiology (A.M.T., J.M.K., R.B., N.E.N.-E., T.J.V., M.G.M.), Johan Wolfgang Goethe University Hospital, Frankfurt am Main, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
M.G. Mack
aFrom the Department of Diagnostic and Interventional Radiology (A.M.T., J.M.K., R.B., N.E.N.-E., T.J.V., M.G.M.), Johan Wolfgang Goethe University Hospital, Frankfurt am Main, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • References
  • PDF
Loading

Abstract

BACKGROUND AND PURPOSE: DECT offers additional image datasets with potential benefits, but its use for H&N imaging is not justified unless image quality is preserved without increased radiation dose. The aim of this work was to compare image quality and radiation dose between a DE-derived WA image dataset and a standard SECT acquisition of the H&N.

MATERIALS AND METHODS: Thirty-two patients underwent DECT of the H&N (tube voltages 80 and Sn140 kVp) and were compared with the last 32 patients who underwent standard SECT (120 kVp) on the same dual-source scanner. WA images from the 2 DE tubes were compared with images obtained with an SE mode. Radiation doses and attenuation measurements of the internal jugular vein, submandibular gland, and sternomastoid and tongue muscles were compared. Objective image noise was compared at 5 anatomic levels. Two blinded readers compared subjective image quality by using 5-point grading scales.

RESULTS: CTDIvol was 12% lower with DE than with SECT, a difference of 1.5 mGy, (P < .0001). Objective noise was not significantly different between DE and SECT at any of the anatomic levels (P > .05). No significant differences in attenuation measurements were observed between DE and SECT (P > .05). No significant differences in subjective image quality scores were observed between DE and SECT at any of the 5 anatomic levels (P > .05).

CONCLUSIONS: DE-derived WA images of the H&N are equivalent to standard SE acquisitions and thus can be used for routine diagnostic purposes. Multiple additional image datasets can be obtained with no radiation dose penalty.

ABBREVIATIONS

CI
confidence interval
CTDIvol
CT volume dose index
DE
dual-energy
DECT
dual-energy CT
DLP
dose-length product
H&N
head and neck
SE
single-energy
SECT
single-energy CT
WA
weighted-average
  • © 2011 by American Journal of Neuroradiology
View Full Text
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 32 (11)
American Journal of Neuroradiology
Vol. 32, Issue 11
1 Dec 2011
  • Table of Contents
  • Index by author
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Image Quality and Radiation Dose of Dual-Energy CT of the Head and Neck Compared with a Standard 120-kVp Acquisition
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Image Quality and Radiation Dose of Dual-Energy CT of the Head and Neck Compared with a Standard 120-kVp Acquisition
A.M. Tawfik, J.M. Kerl, A.A. Razek, R.W. Bauer, N.E. Nour-Eldin, T.J. Vogl, M.G. Mack
American Journal of Neuroradiology Dec 2011, 32 (11) 1994-1999; DOI: 10.3174/ajnr.A2654

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Image Quality and Radiation Dose of Dual-Energy CT of the Head and Neck Compared with a Standard 120-kVp Acquisition
A.M. Tawfik, J.M. Kerl, A.A. Razek, R.W. Bauer, N.E. Nour-Eldin, T.J. Vogl, M.G. Mack
American Journal of Neuroradiology Dec 2011, 32 (11) 1994-1999; DOI: 10.3174/ajnr.A2654
Reddit logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • Abstract
    • ABBREVIATIONS
    • Materials and Methods
    • Results
    • Discussion
    • Conclusions
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • References
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Different Spectral Hounsfield Unit Curve and High-Energy Virtual Monochromatic Image Characteristics of Squamous Cell Carcinoma Compared with Nonossified Thyroid Cartilage
  • Dual-Energy 4-Phase CT Scan in Primary Hyperparathyroidism
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

More in this TOC Section

  • Impact of Kidney Function on CNS Gadolinium Deposition in Patients Receiving Repeated Doses of Gadobutrol
  • Contrast-Induced Acute Kidney Injury in Radiologic Management of Acute Ischemic Stroke in the Emergency Setting
  • Reduction of Radiation Dose and Scanning Time While Preserving Diagnostic Yield: A Comparison of Battery-Powered and Manual Bone Biopsy Systems
Show more Patient Safety

Similar Articles

Advertisement

News and Updates

  • Lucien Levy Best Research Article Award
  • Thanks to our 2022 Distinguished Reviewers
  • Press Releases

Resources

  • Evidence-Based Medicine Level Guide
  • How to Participate in a Tweet Chat
  • AJNR Podcast Archive
  • Ideas for Publicizing Your Research
  • Librarian Resources
  • Terms and Conditions

Opportunities

  • Share Your Art in Perspectives
  • Get Peer Review Credit from Publons
  • Moderate a Tweet Chat

American Society of Neuroradiology

  • Neurographics
  • ASNR Annual Meeting
  • Fellowship Portal
  • Position Statements

© 2023 by the American Society of Neuroradiology | Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire