Research ArticleInterventional
Variable Porosity of the Pipeline Embolization Device in Straight and Curved Vessels: A Guide for Optimal Deployment Strategy
M. Shapiro, E. Raz, T. Becske and P.K. Nelson
American Journal of Neuroradiology April 2014, 35 (4) 727-733; DOI: https://doi.org/10.3174/ajnr.A3742
M. Shapiro
aFrom the Departments of Radiology, Bernard and Irene Schwartz Neurointerventional Radiology Section, (M.S., E.R., T.B., P.K.N.)
cNeurology (M.S., T.B.), New York University Langone Medical Center, New York, New York.
E. Raz
aFrom the Departments of Radiology, Bernard and Irene Schwartz Neurointerventional Radiology Section, (M.S., E.R., T.B., P.K.N.)
T. Becske
aFrom the Departments of Radiology, Bernard and Irene Schwartz Neurointerventional Radiology Section, (M.S., E.R., T.B., P.K.N.)
cNeurology (M.S., T.B.), New York University Langone Medical Center, New York, New York.
P.K. Nelson
aFrom the Departments of Radiology, Bernard and Irene Schwartz Neurointerventional Radiology Section, (M.S., E.R., T.B., P.K.N.)
bNeurosurgery (P.K.N.)
Data supplements
Supplemental Online Figures
Files in this Data Supplement:
- Online Figures (PDF) - see file
In this issue
American Journal of Neuroradiology
Vol. 35, Issue 4
1 Apr 2014
Advertisement
Variable Porosity of the Pipeline Embolization Device in Straight and Curved Vessels: A Guide for Optimal Deployment Strategy
M. Shapiro, E. Raz, T. Becske, P.K. Nelson
American Journal of Neuroradiology Apr 2014, 35 (4) 727-733; DOI: 10.3174/ajnr.A3742
Jump to section
Related Articles
Cited By...
- In vitro flow diversion effect of the ReSolv stent with the shelf technique in a bifurcation aneurysm model
- Pipeline Embolization Device for intracranial aneurysms presenting with mass effect: a large Chinese cohort
- Correlation of Flow Diverter Malapposition at the Aneurysm Neck with Incomplete Aneurysm Occlusion in Patients with Small Intracranial Aneurysms: A Single-Center Experience
- Intraluminal Flow Diverter Design Primer for Neurointerventionalists
- Pipeline Embolization Device for intracranial aneurysms presenting with mass effect: a large Chinese cohort
- In vitro flow diversion effect of the ReSolv stent with the shelf technique in a bifurcation aneurysm model
- Predicting flow diverter sizing using the AneuGuideTM software: a validation study
- Diversion-p64: results from an international, prospective, multicenter, single-arm post-market study to assess the safety and effectiveness of the p64 flow modulation device
- Role of patient-specific blood properties in computational fluid dynamics simulation of flow diverter deployed cerebral aneurysms
- Parent Artery Straightening after Flow-Diverter Stenting Improves the Odds of Aneurysm Occlusion
- The utility of platelet inhibition testing in patients undergoing Pipeline embolization of intracranial aneurysms
- Propensity Score Analysis of Flow Diverters Placed in Scaffolding Stents
- Implementation of computer simulation to assess flow diversion treatment outcomes: systematic review and meta-analysis
- Distal anterior cerebral artery aneurysms treated with flow diversion: experience of a large-volume center and systematic review of the literature
- Flow modification on the internal carotid artery bifurcation region and A1 segment after M1-internal carotid artery flow diverter deployment
- Virtual simulation with Sim&Size software for Pipeline Flex Embolization: evaluation of the technical and clinical impact
- Endosaccular flow disruption: where are we now?
- Pipeline embolization device diameter is an important factor determining the efficacy of flow diversion treatment of small intracranial saccular aneurysms
- Delayed parent artery occlusions following use of SILK flow diverters for treatment of intracranial aneurysms
- On Flow Diversion: The Changing Landscape of Intracerebral Aneurysm Management
- Comparison of Pipeline Embolization Device Sizing Based on Conventional 2D Measurements and Virtual Simulation Using the Sim&Size Software: An Agreement Study
- High-Definition Zoom Mode, a High-Resolution X-Ray Microscope for Neurointerventional Treatment Procedures: A Blinded-Rater Clinical-Utility Study
- Toward Better Understanding of Flow Diversion in Bifurcation Aneurysms
- Pipeline Diameter Significantly Impacts the Long-Term Fate of Jailed Side Branches during Treatment of Intracranial Aneurysms
- Treatment of Distal Anterior Cerebral Artery Aneurysms with Flow-Diverter Stents: A Single-Center Experience
- A comparison between the new Low-profile Visualized Intraluminal Support (LVIS Blue) stent and the Flow Redirection Endoluminal Device (FRED) in bench-top and cadaver studies
- Selection of helical braided flow diverter stents based on hemodynamic performance and mechanical properties
- Large Basilar Apex Aneurysms Treated with Flow-Diverter Stents
- Relationships between geometrical parameters and mechanical properties for a helical braided flow diverter stent
- Compacting a Single Flow Diverter versus Overlapping Flow Diverters for Intracranial Aneurysms: A Computational Study
- Endovascular treatment of intracranial aneurysms using the Pipeline Flex embolization device: a case series of 30 consecutive patients
- Posterior Inferior Cerebellar Artery Patency after Flow-Diverting Stent Treatment
- New Pipeline Flex device: initial experience and technical nuances
- Pipeline endovascular device for the treatment of intracranial aneurysms at the level of the circle of Willis and beyond: multicenter experience
- Preliminary experience with the Pipeline Flex Embolization Device: technical note
- Flow diverters: inter and intra-rater reliability of porosity and pore density measurements
- Urgent off-label use of the pipeline flow diverter stent in selected ischemic cerebrovascular conditions: thrombotic segments and tortuous arteries
- Endoluminal Reconstruction for Nonsaccular Aneurysms of the Proximal Posterior Cerebral Artery with the Pipeline Embolization Device
- Anterior Choroidal Artery Patency and Clinical Follow-Up after Coverage with the Pipeline Embolization Device
- Modifying Flow in the ICA Bifurcation: Pipeline Deployment from the Supraclinoid ICA Extending into the M1 Segment--Clinical and Anatomic Results
- The Success of Flow Diversion in Large and Giant Sidewall Aneurysms May Depend on the Size of the Defect in the Parent Artery
- Building Multidevice Pipeline Constructs of Favorable Metal Coverage: A Practical Guide
This article has been cited by the following articles in journals that are participating in Crossref Cited-by Linking.
- Tibor Becske, Waleed Brinjikji, Matthew B. Potts, David F. Kallmes, Maksim Shapiro, Christopher J. Moran, Elad I. Levy, Cameron G. McDougall, István Szikora, Giuseppe Lanzino, Henry H. Woo, Demetrius K. Lopes, Adnan H. Siddiqui, Felipe C. Albuquerque, David J. Fiorella, Isil Saatci, Saruhan H. Cekirge, Aaron L. Berez, Daniel J. Cher, Zsolt Berentei, Miklós Marosfői, Peter K. NelsonNeurosurgery 2017 80 1
- Maksim Shapiro, Tibor Becske, Peter K. NelsonJournal of Neurosurgery 2017 126 2
- Pierre Bouillot, Olivier Brina, Rafik Ouared, Karl-Olof Lovblad, Mohamed Farhat, Vitor Mendes Pereira, Josué SznitmanPLoS ONE 2014 9 12
- Gary Rajah, Sandra Narayanan, Leonardo Rangel-CastillaNeurosurgical Focus 2017 42 6
- E. Raz, M. Shapiro, T. Becske, D.W. Zumofen, O. Tanweer, M.B. Potts, H.A. Riina, P.K. NelsonAmerican Journal of Neuroradiology 2015 36 5
- Bree Chancellor, Eytan Raz, Maksim Shapiro, Omar Tanweer, Erez Nossek, Howard A Riina, Peter Kim NelsonNeurosurgery 2020 86 Supplement_1
- M Martínez-Galdámez, A Romance, P Vega, A Vega, J L Caniego, L Paul, I Linfante, G DabusJournal of NeuroInterventional Surgery 2015 7 11
- Erez Nossek, David J. Chalif, Shamik Chakraborty, Kim Lombardo, Karen S. Black, Avi SettonJournal of Neurosurgery 2015 122 4
- M. Shapiro, E. Raz, T. Becske, P. K. NelsonAmerican Journal of Neuroradiology 2014 35 8
- Philipp Berg, Christina Iosif, Sebastien Ponsonnard, Catherine Yardin, Gábor Janiga, Charbel MounayerJournal of Biomechanics 2016 49 1
More in this TOC Section
Similar Articles
Advertisement