International Retrospective Study of the Pipeline Embolization Device: A Multicenter Aneurysm Treatment Study

Abstract
BACKGROUND AND PURPOSE: Flow diverters are increasingly used in the endovascular treatment of intracranial aneurysms. Our aim was to determine neurologic complication rates following Pipeline Embolization Device placement for intracranial aneurysm treatment in a real-world setting.
MATERIALS AND METHODS: We retrospectively evaluated all patients with intracranial aneurysms treated with the Pipeline Embolization Device between July 2008 and February 2013 in 17 centers worldwide. We defined 4 subgroups: internal carotid artery aneurysms of ≥10 mm, ICA aneurysms of <10 mm, other anterior circulation aneurysms, and posterior circulation aneurysms. Neurologic complications included spontaneous rupture, intracranial hemorrhage, ischemic stroke, permanent cranial neuropathy, and mortality. Comparisons were made with t tests or ANOVAs for continuous variables and the Pearson χ2 or Fisher exact test for categoric variables.
RESULTS: In total, 793 patients with 906 aneurysms were included. The neurologic morbidity and mortality rate was 8.4% (67/793), highest in the posterior circulation group (16.4%, 9/55) and lowest in the ICA <10-mm group (4.8%, 14/294) (P = .01). The spontaneous rupture rate was 0.6% (5/793). The intracranial hemorrhage rate was 2.4% (19/793). Ischemic stroke rates were 4.7% (37/793), highest in patients with posterior circulation aneurysms (7.3%, 4/55) and lowest in the ICA <10-mm group (2.7%, 8/294) (P = .16). Neurologic mortality was 3.8% (30/793), highest in the posterior circulation group (10.9%, 6/55) and lowest in the anterior circulation ICA <10-mm group (1.4%, 4/294) (P < .01).
CONCLUSIONS: Aneurysm treatment with the Pipeline Embolization Device is associated with the lowest complication rates when used to treat small ICA aneurysms. Procedure-related morbidity and mortality are higher in the treatment of posterior circulation and giant aneurysms.
ABBREVIATIONS:
- IntrePED
- International Retrospective Study of Pipeline Embolization Device
- IPH
- intraparenchymal hemorrhage
- PED
- Pipeline Embolization Device
- © 2015 by American Journal of Neuroradiology
In this issue
Jump to section
Related Articles
Cited By...
- Safety and efficacy results of the Flow Redirection Endoluminal Device (FRED) stent system in the treatment of intracranial aneurysms: US pivotal trial
- Prophylactic administration of tirofiban for preventing thromboembolic events in flow diversion treatment of intracranial aneurysms
- Using angiographic parametric imaging-derived radiomics features to predict complications and embolization outcomes of intracranial aneurysms treated by pipeline embolization devices
- Brazilian FRED Registry: A Prospective Multicenter Study for Brain Aneurysm Treatment--The BRED Study
- Combined standard bypass and parent artery occlusion for management of giant and complex internal carotid artery aneurysms
- The value of long-term angiographic follow-up following Pipeline embolization of intracranial aneurysms
- The utility of platelet inhibition testing in patients undergoing Pipeline embolization of intracranial aneurysms
- Postoperative occlusion degree after flow-diverter placement with adjunctive coiling: analysis of complications
- Mortality after treatment of intracranial aneurysms with the Pipeline Embolization Device
- Review of current intracranial aneurysm flow diversion technology and clinical use
- Neck Location on the Outer Convexity is a Predictor of Incomplete Occlusion in Treatment with the Pipeline Embolization Device: Clinical and Angiographic Outcomes
- Periprocedural to 1-year safety and efficacy outcomes with the Pipeline Embolization Device with Shield technology for intracranial aneurysms: a prospective, post-market, multi-center study
- Diffusion weighted image documented cerebral ischemia in the postprocedural period following pipeline embolization device with shield technology treatment of unruptured intracranial aneurysms: a prospective, single center study
- Flow-Diversion Treatment for Unruptured Nonsaccular Intracranial Aneurysms of the Posterior and Distal Anterior Circulation: A Meta-Analysis
- Prospective study on embolization of intracranial aneurysms with the pipeline device: the PREMIER study 1 year results
- Outcome Study of the Pipeline Embolization Device with Shield Technology in Unruptured Aneurysms (PEDSU)
- Pipeline embolization device diameter is an important factor determining the efficacy of flow diversion treatment of small intracranial saccular aneurysms
- The safety and effectiveness of the Woven EndoBridge (WEB) system for the treatment of wide-necked bifurcation aneurysms: final 12-month results of the pivotal WEB Intrasaccular Therapy (WEB-IT) Study
- Usefulness of Silent MR Angiography for Intracranial Aneurysms Treated with a Flow-Diverter Device
- Antiplatelet therapy and the risk of ischemic and hemorrhagic complications associated with Pipeline embolization of cerebral aneurysms: a systematic review and pooled analysis
- On Flow Diversion: The Changing Landscape of Intracerebral Aneurysm Management
- Treatment of intracranial aneurysms using the pipeline flex embolization device with shield technology: angiographic and safety outcomes at 1-year follow-up
- Treatment of Unruptured Distal Anterior Circulation Aneurysms with Flow-Diverter Stents: A Meta-Analysis
- Safety and efficacy of the Derivo Embolization Device for the treatment of ruptured intracranial aneurysms
- Aneurysm Characteristics, Study Population, and Endovascular Techniques for the Treatment of Intracranial Aneurysms in a Large, Prospective, Multicenter Cohort: Results of the Analysis of Recanalization after Endovascular Treatment of Intracranial Aneurysm Study
- Endothelialization following Flow Diversion for Intracranial Aneurysms: A Systematic Review
- Preliminary outcomes of single antiplatelet therapy for surface-modified flow diverters in an animal model: analysis of neointimal development and thrombus formation using OCT
- Safety and efficacy of the Derivo Embolization Device for the treatment of unruptured intracranial aneurysms: a multicentric study
- Toward Better Understanding of Flow Diversion in Bifurcation Aneurysms
- Pipeline Diameter Significantly Impacts the Long-Term Fate of Jailed Side Branches during Treatment of Intracranial Aneurysms
- Flow-Diversion Effect of LEO Stents: Aneurysm Occlusion and Flow Remodeling of Covered Side Branches and Perforators
- Treatment of Intracranial Aneurysms with Self-Expandable Braided Stents: A Systematic Review and Meta-Analysis
- Procedural complexity independent of P2Y12 reaction unit (PRU) values is associated with acute in situ thrombosis in Pipeline flow diversion of cerebral aneurysms
- PED Flex with Shield Technology: a feasible alternative for fusiform MCA aneurysms
- Acutely Ruptured Intracranial Aneurysms Treated with Flow-Diverter Stents: A Systematic Review and Meta-Analysis
- Risk of Branch Occlusion and Ischemic Complications with the Pipeline Embolization Device in the Treatment of Posterior Circulation Aneurysms
- Indications for the Performance of Intracranial Endovascular Neurointerventional Procedures: A Scientific Statement From the American Heart Association
- Endovascular Treatment of Very Large and Giant Intracranial Aneurysms: Comparison between Reconstructive and Deconstructive Techniques--A Meta-Analysis
- Parent Artery Reconstruction for Large or Giant Cerebral Aneurysms Using the Tubridge Flow Diverter: A Multicenter, Randomized, Controlled Clinical Trial (PARAT)
- Middle cerebral artery flow velocity increases more in patients with delayed intraparenchymal hemorrhage after Pipeline
- Contemporary endovascular and open aneurysm treatment in the era of flow diversion
- Expanding the use of flow diverters beyond their initial indication: treatment of small unruptured aneurysms
- A comparison between the new Low-profile Visualized Intraluminal Support (LVIS Blue) stent and the Flow Redirection Endoluminal Device (FRED) in bench-top and cadaver studies
- Tourniquet parent artery occlusion after flow diversion
- The Role of Hemodynamics in Intracranial Bifurcation Arteries after Aneurysm Treatment with Flow-Diverter Stents
- Analysis of neointima development in flow diverters using optical coherence tomography imaging
- Treatment of Middle Cerebral Artery Aneurysms with Flow-Diverter Stents: A Systematic Review and Meta-Analysis
- Early angiographic signs of acute thrombus formation following cerebral aneurysm treatment with the Pipeline embolization device
- In situ tissue engineering: endothelial growth patterns as a function of flow diverter design
- P2Y12 hyporesponse (PRU>200) is not associated with increased thromboembolic complications in anterior circulation Pipeline
- Periprocedural outcomes and early safety with the use of the Pipeline Flex Embolization Device with Shield Technology for unruptured intracranial aneurysms: preliminary results from a prospective clinical study
- Endovascular flow diversion for treatment of anterior communicating artery region cerebral aneurysms: a single-center cohort of 50 cases
- Incidence of delivery wire recapture failure with the Pipeline Flex device
- First US experience with Pipeline Flex with Shield Technology using aspirin as antiplatelet monotherapy
- Lack of Association between Statin Use and Angiographic and Clinical Outcomes after Pipeline Embolization for Intracranial Aneurysms
- Flow Diversion in Ruptured Intracranial Aneurysms: A Meta-Analysis
- Concomitant coiling reduces metalloproteinase levels in flow diverter-treated aneurysms but anti-inflammatory treatment has no effect
- Use of Pipeline Flex is associated with reduced fluoroscopy time, procedure time, and technical failure compared with the first-generation Pipeline embolization device
- Carotid cavernous fistula after Pipeline placement: a single-center experience and review of the literature
This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.