Advanced Search

  • Home
  • Content
    • Current Issue
    • Publication Preview--Ahead of Print
    • Past Issue Archive
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
    • COVID-19 Content and Resources
  • About Us
    • About AJNR
    • Editorial Board
    • American Society of Neuroradiology
  • For Authors
    • Author Policies
    • Manuscript Submission Guidelines
  • Submit a Manuscript
  • Podcasts
    • Podcasts
    • Subscribe on iTunes
  • More
    • Subscribers
    • Permissions
    • Advertisers
    • Alerts
    • Feedback
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds
Research ArticleINTERVENTIONAL

Pipeline Embolization Device with or without Adjunctive Coil Embolization: Analysis of Complications from the IntrePED Registry

M.S. Park, C. Kilburg, P. Taussky, F.C. Albuquerque, D.F. Kallmes, E.I. Levy, P. Jabbour, I. Szikora, E. Boccardi, R.A. Hanel, A. Bonafé and C.G. McDougall
American Journal of Neuroradiology June 2016, 37 (6) 1127-1131; DOI: https://doi.org/10.3174/ajnr.A4678
M.S. Park
aFrom the Department of Neurosurgery (M.S.P., C.K., P.T.), University of Utah Health Care, Salt Lake City, Utah
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for M.S. Park
C. Kilburg
aFrom the Department of Neurosurgery (M.S.P., C.K., P.T.), University of Utah Health Care, Salt Lake City, Utah
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for C. Kilburg
P. Taussky
aFrom the Department of Neurosurgery (M.S.P., C.K., P.T.), University of Utah Health Care, Salt Lake City, Utah
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for P. Taussky
F.C. Albuquerque
bDepartment of Neurosurgery (F.C.A., C.G.M.), Barrow Neurological Institute, Phoenix, Arizona
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for F.C. Albuquerque
D.F. Kallmes
cDepartment of Radiology (D.F.K.), Mayo Clinic, Rochester, Minnesota
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for D.F. Kallmes
E.I. Levy
dDepartment of Neurosurgery (E.I.L.), University of Buffalo, Buffalo, New York
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for E.I. Levy
P. Jabbour
eDepartment of Neurosurgery (P.J.), Thomas Jefferson University, Philadelphia, Pennsylvania
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for P. Jabbour
I. Szikora
fDepartment of Neurointerventions (I.S.), National Institute of Neurosciences, Budapest, Hungary
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for I. Szikora
E. Boccardi
gDepartment of Neuroradiology (E.B.), Ospedale Niguarda Ca' Granda, Milan, Italy
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for E. Boccardi
R.A. Hanel
hDepartment of Neurosurgery (R.A.H.), Baptist Health, Jacksonville, Florida
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for R.A. Hanel
A. Bonafé
iDepartment of Neuroradiology (A.B.), Hôpital Gui de Chauliac, Montpellier, France.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for A. Bonafé
C.G. McDougall
bDepartment of Neurosurgery (F.C.A., C.G.M.), Barrow Neurological Institute, Phoenix, Arizona
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for C.G. McDougall
  • Article
  • Figures & Data
  • Info & Metrics
  • References
  • PDF
Loading

Abstract

SUMMARY: Flow diversion to treat cerebral aneurysms has revolutionized neurointerventional surgery. Because the addition of coils potentially increases the time and complexity of endovascular procedures, we sought to determine whether adjunctive coil use is associated with an increase in complications. Patients in the International Retrospective Study of Pipeline Embolization Device registry were divided into those treated with the Pipeline Embolization Device alone (n = 689 patients; n = 797 aneurysms; mean aneurysm size, 10.3 ± 7.6 mm) versus those treated with the Pipeline Embolization Device and concurrent coil embolization (n = 104 patients; n = 109 aneurysms; mean aneurysm size, 13.6 ± 7.8 mm). Patient demographics and aneurysm characteristics were examined. Rates of neurologic morbidity and mortality were compared between groups. The Pipeline Embolization Device with versus without coiling required a significantly longer procedure time (135.8 ± 63.9 versus 96.7 ± 46.2 min; P < .0001) and resulted in higher neurological morbidity (12.5% versus 7.8%; P = .13). These data suggest that either strategy represents an acceptable risk profile in the treatment of complex cerebral aneurysms and warrants further investigation.

ABBREVIATIONS:

IntrePED
International Retrospective Study of Pipeline Embolization Device
PED
Pipeline Embolization Device

The recent development of flow diversion for cerebral aneurysms that are difficult to treat has ushered in an exciting time in the world of neurointerventional surgery.1⇓⇓⇓⇓⇓⇓⇓⇓⇓⇓⇓⇓⇓⇓⇓–17 Reports in the literature, however, are conflicting concerning the optimal strategy in using this new device.1,2,4,13,15,16,18⇓⇓–21 The addition of coil embolization to flow diversion, while prevalent in daily use, has not been subjected to a large systematic analysis.7⇓⇓⇓–11,16,21⇓⇓–24 The earliest case report hypothesized that coils within the aneurysm sac can augment the degree of flow diversion with the goal of improved occlusion of the aneurysm.1 Others believe that adjunctive coil embolization does little to improve the already high occlusion rates obtained by using the Pipeline Embolization Device (PED; Covidien, Irvine, California) alone.21 Furthermore, there have been reports of complications associated with overly dense coil embolization of aneurysms in this setting.22

We analyzed the International Retrospective Study of Pipeline Embolization Device (IntrePED [ClinicalTrials.gov identifier: NCT01558102]) data to determine whether there was an increase in neurologic complications associated with the use of the PED and adjunctive coil embolization.

Materials and Methods

This study is a subanalysis of IntrePED registry data obtained from a multicenter, observational, international registry of patients treated with the PED. The primary objective of IntrePED was to identify any neurologic events following treatment with the PED. The IntrePED registry includes patients treated with the PED starting in July 2008 and concluding in July 2013, following the enrollment of 793 patients. Because the study was conducted retrospectively, the protocol did not specify the coiling methodology, and the decision to use coils with the PED was left to the discretion of the treating physician. Details regarding the institutional review board and ethics committee approvals, patient population, and protocol requirements are described in the primary IntrePED article.17

This subanalysis was performed to compare the safety outcomes of patients treated with the PED alone (PED group) with those of patients treated with the PED and adjunctive coil embolization (PED/coil group). Data collected for analysis were basic demographic information, including patient age, sex, and history of aneurysm rupture; aneurysm characteristics, including aneurysm size, neck size, shape, and location; procedural data, including procedure time and devices used; and follow-up data, including any complications. The primary outcomes were neurologic mortality and combined neurologic morbidity and mortality. Neurologic morbidity was predefined as the composite of the following neurologic complications: spontaneous aneurysm rupture, ipsilateral intracranial hemorrhage, ischemic stroke, parent artery stenosis, and cranial neuropathy. These complications were characterized as major or minor, with “major” defined as an ongoing clinical deficit at 7 days after the event. All major adverse events are included in the neurologic morbidity and mortality rates.

The data were analyzed to determine whether there were any significant differences between those patients treated with the PED alone versus those treated with the PED and adjunctive coils. Differences in continuous variables between the 2 groups were tested by using the Wilcoxon rank sum test. Differences in categoric variables between groups were analyzed by using the χ2 or Fisher exact test. Data are presented as the number of events and percentage or mean ± SD unless otherwise noted; P values < .05 were statistically significant. Most statistical analyses were performed across patient groups on a per-patient basis. When determining aneurysm size, we categorized patients with multiple aneurysms on the basis of the size of the largest aneurysm. Analysis of aneurysm characteristics was performed across all aneurysms rather than across patients.

Results

The registry included 793 patients with 906 aneurysms: 689 patients with 797 aneurysms were treated with the PED alone, and 104 patients with 109 aneurysms were treated with PED/coil (Table 1). While the patient ages, sex, and length of follow-up were well matched, procedure times were significantly increased for the PED/coil cohort compared with the PED alone group (135.8 ± 63.9 minutes versus 96.7 ± 46.2 minutes, P < .0001).

View this table:
  • View inline
  • View popup
Table 1:

Patient details

The mean aneurysm and neck sizes were statistically larger in the PED/coil cohort than in the PED alone group (aneurysm size, 13.6 ± 7.8 mm versus 10.3 ± 7.6 mm, P < .0001; neck size, 6.4 ± 3.0 mm versus 6.2 ± 5.1 mm, P = .017) (Table 2). These larger aneurysms were also more likely to require multiple PEDs during treatment (Table 3). There was also a statistically significant difference in the location of aneurysms treated between the 2 groups (P < .0001). There were significantly fewer internal carotid artery aneurysms treated in the PED/coil cohort compared with the PED alone group (64.2% versus 77%, P = .006). There were significantly more basilar artery aneurysms treated by PED/coil compared with PED alone (14.7% versus 3.5%, P < .0001). There was no statistically significant difference in presentation with subarachnoid hemorrhage between the 2 groups (PED/coil 11.9% versus PED alone 7.9%, P = .155).

View this table:
  • View inline
  • View popup
Table 2:

Aneurysm characteristics

View this table:
  • View inline
  • View popup
Table 3:

Multiple PED use

Overall, 13 of 104 (12.5%) patients in the PED/coil cohort experienced a major neurologic complication and/or mortality versus 54 of 689 (7.8%) patients in the PED alone cohort (P = .13) (Table 4). Neither the overall nor the individual complication rates reached statistical significance.

View this table:
  • View inline
  • View popup
Table 4:

Patient outcomes

Discussion

While the use of adjunctive coil embolization with the PED is not novel, there are questions regarding the efficacy of, and the potential for, increased complications with this strategy compared with PED embolization alone. Certain authors have advocated coil embolization as a method of improving occlusion rates and minimizing the potential for catastrophic aneurysm rupture following the use of flow-diverting stents.23,25,26 Others have argued that the addition of coil embolization to the procedure yields no significant added advantage in regard to treatment efficacy.21 However, our single-center results, which have been previously presented, did identify a statistically significant increase in the need for retreatment with a strategy of PED alone versus PED/coil.27

Additionally, we previously reported our overall (31.7%) and permanent complication (3.2%) rates following use of the PED.19 However, we did not examine any potential differences in complications between these 2 treatment strategies. In an earlier report on the PED, Siddiqui et al22 described a patient with a giant middle cerebral artery aneurysm treated with 2 PEDs and dense coil embolization. The patient had an acute thrombosis of the PED following the procedure, which was attributed to the dense coil mass. The authors recommended avoiding dense packing of aneurysms when coil embolization is used as an adjunctive treatment with the PED.

In a recent series published by Lin et al,23 75 patients treated with the PED alone were compared with 29 patients treated with the PED and adjunctive coil embolization. There was no statistically significant difference in the complication rates between the 2 groups (10.3% with PED/coil versus 8.0% with PED alone, P = .7). Lin et al found, as we did in the IntrePED study, that aneurysms treated with a strategy of PED/coil were statistically larger than aneurysms treated with PED alone (16.3 versus 12.4 mm, P = .02). Nossek et al26 also found similar results in 25 consecutive patients with unruptured aneurysms treated with the PED and adjunctive coiling.

Szikora et al21 described their series of 19 patients with wide-neck intracranial aneurysms treated with a strategy of both PED/coil and PED alone. Initially, they treated patients with adjunctive coil embolization, maintaining low coil-packing densities; however, they switched to a strategy of overlapping PEDs without coiling in the latter part of their series. Despite the 2 differing strategies, they had similar occlusion rates at the 6-month follow-up interval. Although their overall complication rate (1 permanent nonrestricting morbidity and 1 mortality) was within the rates published in the literature, they did not specify which treatment strategy was associated with these complications.

In the IntrePED registry, there was a statistically significant difference in the aneurysm size between the 2 cohorts we evaluated (P < .0001). Aneurysms treated with adjunctive coil embolization were larger in both aneurysm size and aneurysm neck size. These differences are likely related to the individual clinician's judgment in regard to the efficacy of stand-alone PED placement for this subset of aneurysms. There may have been a stronger desire to have more immediate contrast stasis during the initial treatment of larger aneurysms due to the higher chance of spontaneous rupture with increasing aneurysm size. In this instance, 2 options for increasing stasis would be to add coil embolization or to place multiple PEDs across the aneurysm neck. Potentially, the use of multiple PEDs may also increase the rate of complications during the procedure. However, we did not identify a difference in the percentage of aneurysms treated with multiple PEDs in either cohort. Patients with larger aneurysms, however, were more likely to have multiple PEDs deployed in both groups (PED alone versus PED/coil).

Another interesting finding in our analysis is the statistically significant difference in the location of aneurysms treated by either strategy. Again, this is likely related to clinical judgment in terms of the aneurysm characteristics and their relationship to the parent vessel. Additionally, endovascular surgeons may be more reluctant to use adjunctive coil embolization when using flow diverters in the posterior cerebral artery/posterior circulation, which is currently an off-label indication in some countries.

While one may presuppose a higher intraprocedural rupture rate with a strategy of PED and adjunctive coils, this was not apparent in our findings. Even with manipulation of the aneurysm wall/dome during coil embolization, there was no statistically significant increased rate of ipsilateral intracranial hemorrhage during or following the procedure. While the anatomical differences between the aneurysms in the 2 cohorts may have certainly influenced the practitioner's judgment as to the optimal treatment strategy, there were no statistically significant differences in the primary or secondary end points for either treatment strategy. Overall, the complication rates reported for the patients in the IntrePED registry for either treatment strategy are in line with those in the published literature for use of flow-diverting stents.19

Once the decision is made to use adjunctive coil embolization, the setup and performance of the procedure may be distinctly different from those used in deploying a PED alone. First, one must decide whether to coil the aneurysm before or after placement of the flow-diverting stent. One can choose to proceed first with primary or balloon-assisted coil embolization followed by PED deployment. While this strategy would not significantly affect the deployment of the PED from a guide catheter standpoint, it does add the time required to perform the initial embolization to the overall procedure. Once coils are placed within the aneurysm, the microcatheter or balloon microcatheter or both are removed, allowing unencumbered navigation of the catheters for PED deployment. This technique, however, can potentially obscure visualization of the PED during deployment.

Alternatively, one can jail a microcatheter within the aneurysm and initially place the PED followed by aneurysm coiling. This strategy, however, may affect the choice of support catheters. One must ensure that the inner diameter of the guide catheter is sufficiently large enough to support simultaneous navigation of the Marksman catheter (Covidien) and the microcatheter to be used for coil embolization. The use of a second microcatheter for coiling placed through the same guide catheter as the Marksman catheter would likely preclude the use of additional catheters (ie, distal-access catheters) to support PED deployment due to limitations in guide-catheter size. Despite the increase in procedural times and/or case complexity, there was no statistically significant increase in the overall complication rate in terms of neurologic morbidity and mortality in our analysis.

Limitations

Our study is limited by its retrospective nature, with participating sites following their standard practice for treating aneurysms with PEDs. As a result, the decision to use adjunctive coil embolization was left to the discretion of the treating physician and was not standardized across centers. Because the IntrePED study was a retrospective, observational study without preplanned subgroup analysis, no prespecified differences were expected between these 2 cohorts. Additionally, no power analysis was performed. While there are certain inherent limitations with this type of study, we believe that the conclusions may still be clinically relevant.

Conclusions

Decisions about which strategy to use when faced with a complex cerebral aneurysm are made largely at the discretion of, and with the judgment of, the practitioner. There have been few large series comparing PED alone versus PED with coiling in terms of overall efficacy in aneurysm treatment. While there was a statistically significant difference in aneurysm size and location and procedural times in the IntrePED registry between our 2 cohorts, there was no statistically significant difference in overall complications. These data suggest that either strategy represents an acceptable risk profile in the treatment of complex cerebral aneurysms and warrants further investigation.

Acknowledgments

We thank Ms Suzanne LaScalza and Mei Jiang, PhD, for assistance with statistical analysis. The IntrePED observational registry was funded and supported by Covidien/Medtronic, with scientific oversight of the study by the steering committee.

Footnotes

  • Disclosures: Min S. Park—RELATED: Other: Covidien/Medtronic, Comments: Covidien provided statistical analysis support for the article (as described in our acknowledgments). No money was provided as part of the preparation, writing, submission, or any other aspects of this work. Phillipp Taussky—RELATED: Consulting Fee or Honorarium: Covidien/Medtronic (Pipeline proctor). David F. Kallmes—RELATED: Grant: ev3/Covidien/Medtronic,* Comments: support for clinical trial; Consulting Fee or Honorarium: ev3/Covidien/Medtronic,* Comments: Steering Committee for clinical trial; Fees for Participation in Review Activities, Such as Data Monitoring Boards, Statistical Analysis, Endpoint Committees, and the Like: ev3/Covidien/Medtronic,* Comments: Safety Committee; UNRELATED: Board Membership: GE Healthcare Cost-Effectiveness Board*; Consultancy: ev3/Covidien/Medtronic,* Comments: clinical trials support; Grants/Grants Pending: MicroVention,* Codman Neuro/DePuy Synthes,* NeuroSigma,* SurModics,* Sequent Medical,* ev3/Covidien/Medtronic,* Comments: support for clinical and preclinical research; Patents (planned, pending or issued): Mayo Medical Ventures,* Comments: augmentation patent; Royalties: University of Virginia Patent Foundation (Spine Fusion); Travel/Accommodations/Meeting Expenses Unrelated to Activities Listed: ev3/Covidien/Medtronic,* Comments: travel to FDA panel meeting. Elad I. Levy—UNRELATED: Board Membership: Stryker (American Spinal Injury Association Impairment Scale [AIS] Clinical Advisory Board), Next-Gen Biologics (Advisory Board); Consultancy: Pulsar Vascular (unpaid); Expert Testimony: renders medical/legal opinion as an expert witness; Payment for Lectures (including service on Speakers Bureaus): Covidien/Medtronic (honorarium for lectures), Stryker; Payment for Development of Educational Presentations: Covidien/Medtronic Abbott, Comments: honorarium for training for Covidien/Medtronic and carotid training sessions for Abbott for physicians; Stock/Stock Options: Blockade Medical, Intratech Medical, Medina Medical; Other: Covidien/Medtronic (National Principal Investigator for Solitaire with the Intention for Thrombectomy as Primary Endovascular Treatment for Acute Ischemic Stroke trials). Pascal Jabbour—UNRELATED: Consultancy: Covidien (Pipeline proctor). István Szikora—RELATED: Consulting Fee or Honorarium: Covidien/Medtronic; Support for Travel to Meetings for the Study or Other Purposes: Covidien/Medtronic; UNRELATED: Consultancy: Covidien/Medtronic, Stryker, Codman, Sequent Medical. Edoardo Boccardi—RELATED: Consulting Fee or Honorarium: Covidien/Medtronic; UNRELATED: Consultancy: Covidien/Medtronic, Stryker, MicroVention. Ricardo A. Hanel—RELATED: Consulting Fee or Honorarium: Covidien/Medtronic; UNRELATED: Board Membership: Medina Medical; Consultancy: Stryker, Codman, MicroVention; Stock/Stock Options: Blockade Medical. Alain Bonafé—UNRELATED: Consultancy: Covidien/Medtronic. Cameron G. McDougall—RELATED: Consulting Fee or Honorarium: Covidien/Medtronic; UNRELATED: Consultancy: MicroVention. *Money paid to the institution.

References

  1. 1.↵
    1. Fiorella D,
    2. Woo HH,
    3. Albuquerque FC, et al
    . Definitive reconstruction of circumferential, fusiform intracranial aneurysms with the Pipeline embolization device. Neurosurgery 2008;62:1115–20; discussion 1120–21 doi:10.1227/01.neu.0000325873.44881.6e pmid:18580809
    CrossRefPubMed
  2. 2.↵
    1. Lylyk P,
    2. Miranda C,
    3. Ceratto R, et al
    . Curative endovascular reconstruction of cerebral aneurysms with the Pipeline embolization device: the Buenos Aires experience. Neurosurgery 2009;64:632–42; discussion 642–43; quiz N6 doi:10.1227/01.NEU.0000339109.98070.65 pmid:19349825
    CrossRefPubMed
  3. 3.↵
    1. Nelson PK,
    2. Lylyk P,
    3. Szikora I, et al
    . The Pipeline embolization device for the intracranial treatment of aneurysms trial. AJNR Am J Neuroradiol 2011;32:34–40 doi:10.3174/ajnr.A2421 pmid:21148256
    Abstract/FREE Full Text
  4. 4.↵
    1. Chalouhi N,
    2. Zanaty M,
    3. Whiting A, et al
    . Safety and efficacy of the Pipeline embolization device in 100 small intracranial aneurysms. J Neurosurg 2015;122:1498–502 doi:10.3171/2014.12.JNS14411 pmid:25635478
    CrossRefPubMed
  5. 5.↵
    1. Zanaty M,
    2. Chalouhi N,
    3. Starke RM, et al
    . Flow diversion versus conventional treatment for carotid cavernous aneurysms. Stroke 2014;45:2656–61 doi:10.1161/STROKEAHA.114.006247 pmid:25052318
    Abstract/FREE Full Text
  6. 6.↵
    1. Tse MM,
    2. Yan B,
    3. Dowling RJ, et al
    . Current status of Pipeline embolization device in the treatment of intracranial aneurysms: a review. World Neurosurg 2013;80:829–35 doi:10.1016/j.wneu.2012.09.023 pmid:23041067
    CrossRefPubMed
  7. 7.↵
    1. Saatci I,
    2. Yavuz K,
    3. Ozer C, et al
    . Treatment of intracranial aneurysms using the Pipeline flow-diverter embolization device: a single-center experience with long-term follow-up results. AJNR Am J Neuroradiol 2012;33:1436–46 doi:10.3174/ajnr.A3246 pmid:22821921
    Abstract/FREE Full Text
  8. 8.↵
    1. Fischer S,
    2. Vajda Z,
    3. Aguilar Perez M, et al
    . Pipeline embolization device (PED) for neurovascular reconstruction: initial experience in the treatment of 101 intracranial aneurysms and dissections. Neuroradiology 2012;54:369–82 doi:10.1007/s00234-011-0948-x pmid:21881914
    CrossRefPubMed
  9. 9.↵
    1. McAuliffe W,
    2. Wycoco V,
    3. Rice H, et al
    . Immediate and midterm results following treatment of unruptured intracranial aneurysms with the Pipeline embolization device. AJNR Am J Neuroradiol 2012;33:164–70 doi:10.3174/ajnr.A2727 pmid:21979492
    Abstract/FREE Full Text
  10. 10.↵
    1. Chitale R,
    2. Gonzalez LF,
    3. Randazzo C, et al
    . Single center experience with Pipeline stent: feasibility, technique, and complications. Neurosurgery 2012;71:679–91; discussion 691 doi:10.1227/NEU.0b013e318260fe86 pmid:22653389
    CrossRefPubMed
  11. 11.↵
    1. Becske T,
    2. Kallmes DF,
    3. Saatci I, et al
    . Pipeline for uncoilable or failed aneurysms: results from a multicenter clinical trial. Radiology 2013;267:858–68 doi:10.1148/radiol.13120099 pmid:23418004
    CrossRefPubMed
  12. 12.↵
    1. Deutschmann HA,
    2. Wehrschuetz M,
    3. Augustin M, et al
    . Long-term follow-up after treatment of intracranial aneurysms with the Pipeline embolization device: results from a single center. AJNR Am J Neuroradiol 2012;33:481–86 doi:10.3174/ajnr.A2790 pmid:22158922
    Abstract/FREE Full Text
  13. 13.↵
    1. Briganti F,
    2. Delehaye L,
    3. Leone G, et al
    . Flow diverter device for the treatment of small middle cerebral artery aneurysms. J Neurointerv Surg 2015 Jan 20. [Epub ahead of print] doi:10.1136/neurintsurg-2014-011460 pmid:25603808
    Abstract/FREE Full Text
  14. 14.↵
    1. Zanaty M,
    2. Chalouhi N,
    3. Barros G, et al
    . Flow-diversion for ophthalmic segment aneurysms. Neurosurgery 2015;76:286–89; discussion 289–90 doi:10.1227/NEU.0000000000000607 pmid:25584955
    CrossRefPubMed
  15. 15.↵
    1. Navarro R,
    2. Brown BL,
    3. Beier A, et al
    . Flow diversion for complex intracranial aneurysms in young children. J Neurosurg Pediatr 2015;15:276–81 doi:10.3171/2014.9.PEDS14333 pmid:25555114
    CrossRefPubMed
  16. 16.↵
    1. Chalouhi N,
    2. Zanaty M,
    3. Whiting A, et al
    . Treatment of ruptured intracranial aneurysms with the Pipeline embolization device. Neurosurgery 2015;76:165–72; discussion 172 doi:10.1227/NEU.0000000000000586 pmid:25549187
    CrossRefPubMed
  17. 17.↵
    1. Kallmes DF,
    2. Hanel R,
    3. Lopes D, et al
    . International retrospective study of the Pipeline embolization device: a multicenter aneurysm treatment study. AJNR Am J Neuroradiol 2015;36:108–15 doi:10.3174/ajnr.A4111 pmid:25355814
    Abstract/FREE Full Text
  18. 18.↵
    1. Chalouhi N,
    2. Tjoumakaris S,
    3. Phillips JL, et al
    . A single Pipeline embolization device is sufficient for treatment of intracranial aneurysms. AJNR Am J Neuroradiol 2014;35:1562–66 doi:10.3174/ajnr.A3957 pmid:24788125
    Abstract/FREE Full Text
  19. 19.↵
    1. Park MS,
    2. Albuquerque FC,
    3. Nanaszko M, et al
    . Critical assessment of complications associated with use of the Pipeline embolization device. J Neurointerv Surg 2015;7:652–69 doi:10.1136/neurintsurg-2014-011265 pmid:24968879
    Abstract/FREE Full Text
  20. 20.↵
    1. Siddiqui AH,
    2. Abla AA,
    3. Kan P, et al
    . Panacea or problem: flow diverters in the treatment of symptomatic large or giant fusiform vertebrobasilar aneurysms. J Neurosurg 2012;116:1258–66 doi:10.3171/2012.2.JNS111942 pmid:22404673
    CrossRefPubMed
  21. 21.↵
    1. Szikora I,
    2. Berentei Z,
    3. Kulcsar Z, et al
    . Treatment of intracranial aneurysms by functional reconstruction of the parent artery: the Budapest experience with the Pipeline embolization device. AJNR Am J Neuroradiol 2010;31:1139–47 doi:10.3174/ajnr.A2023 pmid:20150304
    Abstract/FREE Full Text
  22. 22.↵
    1. Siddiqui AH,
    2. Kan P,
    3. Abla AA, et al
    . Complications after treatment with Pipeline embolization for giant distal intracranial aneurysms with or without coil embolization. Neurosurgery 2012;71:E509–13; discussion E513 doi:10.1227/NEU.0b013e318258e1f8 pmid:22710418
    CrossRefPubMed
  23. 23.↵
    1. Lin N,
    2. Brouillard AM,
    3. Krishna C, et al
    . Use of coils in conjunction with the Pipeline embolization device for treatment of intracranial aneurysms. Neurosurgery 2015;76:142–49 doi:10.1227/NEU.0000000000000579 pmid:25255261
    CrossRefPubMed
  24. 24.↵
    1. Dornbos D 3rd.,
    2. Pillai P,
    3. Sauvageau E
    . Flow diverter assisted coil embolization of a very small ruptured ophthalmic artery aneurysm. J Neurointerv Surg 2013 Dec 11. [Epub ahead of print] doi:10.1136/neurintsurg-2013-010876.rep pmid:24335806
    Abstract/FREE Full Text
  25. 25.↵
    1. Turowski B,
    2. Macht S,
    3. Kulcsár Z, et al
    . Early fatal hemorrhage after endovascular cerebral aneurysm treatment with a flow diverter (SILK-Stent): do we need to rethink our concepts? Neuroradiology 2011;53:37–41 doi:10.1007/s00234-010-0676-7 pmid:20339842
    CrossRefPubMed
  26. 26.↵
    1. Nossek E,
    2. Chalif DJ,
    3. Chakraborty S, et al
    . Concurrent use of the Pipeline embolization device and coils for intracranial aneurysms: technique, safety, and efficacy. J Neurosurg 2015;122:904–11 doi:10.3171/2014.12.JNS141259 pmid:25658781
    CrossRefPubMed
  27. 27.↵
    1. Park MS,
    2. Nanaszko M,
    3. Sanborn MR, et al
    . Re-treatment rates after treatment with the Pipeline embolization device alone versus Pipeline and coil embolization of cerebral aneurysms: a single-center experience. J Neurosurg 2015 Dec 18. [Epub ahead of print] doi:10.3171/2015.7.JNS15582 pmid:26684772
    CrossRefPubMed
  • Received July 14, 2015.
  • Accepted after revision November 18, 2015.
  • © 2016 by American Journal of Neuroradiology
View Abstract
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 37 (6)
American Journal of Neuroradiology
Vol. 37, Issue 6
1 Jun 2016
  • Table of Contents
  • Index by author
  • Complete Issue (PDF)
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Pipeline Embolization Device with or without Adjunctive Coil Embolization: Analysis of Complications from the IntrePED Registry
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Pipeline Embolization Device with or without Adjunctive Coil Embolization: Analysis of Complications from the IntrePED Registry
M.S. Park, C. Kilburg, P. Taussky, F.C. Albuquerque, D.F. Kallmes, E.I. Levy, P. Jabbour, I. Szikora, E. Boccardi, R.A. Hanel, A. Bonafé, C.G. McDougall
American Journal of Neuroradiology Jun 2016, 37 (6) 1127-1131; DOI: 10.3174/ajnr.A4678

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Pipeline Embolization Device with or without Adjunctive Coil Embolization: Analysis of Complications from the IntrePED Registry
M.S. Park, C. Kilburg, P. Taussky, F.C. Albuquerque, D.F. Kallmes, E.I. Levy, P. Jabbour, I. Szikora, E. Boccardi, R.A. Hanel, A. Bonafé, C.G. McDougall
American Journal of Neuroradiology Jun 2016, 37 (6) 1127-1131; DOI: 10.3174/ajnr.A4678
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • Abstract
    • ABBREVIATIONS:
    • Materials and Methods
    • Results
    • Discussion
    • Conclusions
    • Acknowledgments
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • References
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Postoperative occlusion degree after flow-diverter placement with adjunctive coiling: analysis of complications
  • Aneurysm Remnants after Flow Diversion: Clinical and Angiographic Outcomes
  • A new method to statistically describe microcatheter tip position in patient-specific aneurysm models
  • Single-stage flow diversion with adjunctive coiling for cerebral aneurysm: outcomes and technical considerations in 72 cases
  • An outcomes-based grading scale for the evaluation of cerebral aneurysms treated with flow diversion
  • Flow Diversion in Ruptured Intracranial Aneurysms: A Meta-Analysis
  • Carotid cavernous fistula after Pipeline placement: a single-center experience and review of the literature
  • Crossref (45)
  • Google Scholar

This article has been cited by the following articles in journals that are participating in Crossref Cited-by Linking.

  • Flow Diversion in Ruptured Intracranial Aneurysms: A Meta-Analysis
    T.P. Madaelil, C.J. Moran, D.T. Cross, A.P. Kansagra
    American Journal of Neuroradiology 2017 38 3
  • Quantitative Assessment of In-Stent Stenosis After Pipeline Embolization Device Treatment of Intracranial Aneurysms: A Single-Institution Series and Systematic Review
    Krishnan Ravindran, Mohamed M. Salem, Alejandro Enriquez-Marulanda, Abdulrahman Y. Alturki, Justin M. Moore, Ajith J. Thomas, Christopher S. Ogilvy
    World Neurosurgery 2018 120
  • Introduction: History and Development of Flow Diverter Technology and Evolution
    Anna Luisa Kühn, Matthew J Gounis, Ajit S Puri
    Neurosurgery 2020 86 Supplement_1
  • Pipeline Embolization Device for intracranial aneurysms in a large Chinese cohort: factors related to aneurysm occlusion
    Bin Luo, Huibin Kang, Hongqi Zhang, Tianxiao Li, Jianmin Liu, Donglei Song, Yuanli Zhao, Sheng Guan, Aisha Maimaitili, Yunyan Wang, Wenfeng Feng, Yang Wang, Jieqing Wan, Guohua Mao, Huaizhang Shi, Xinjian Yang
    Therapeutic Advances in Neurological Disorders 2020 13
  • Pipeline-assisted coiling versus pipeline in flow diversion treatment of intracranial aneurysms
    A. Sweid, E. Atallah, N. Herial, H. Saad, N. Mouchtouris, G. Barros, M.R. Gooch, S. Tjoumakaris, H. Zarzour, D. Hasan, N. Chalouhi, R.H. Rosenwasser, P. Jabbour
    Journal of Clinical Neuroscience 2018 58
  • Matched Comparison of Flow Diversion and Coiling in Small, Noncomplex Intracranial Aneurysms
    Nohra Chalouhi, Badih Daou, Guilherme Barros, Robert M. Starke, Ameet Chitale, George Ghobrial, Richard Dalyai, David Hasan, L. Fernando Gonzalez, Stavropoula Tjoumakaris, Robert H. Rosenwasser, Pascal Jabbour
    Neurosurgery 2017 81 1
  • Pipeline Embolization Device in Treatment of 50 Unruptured Large and Giant Aneurysms
    Nimer Adeeb, Christoph J. Griessenauer, Hussain Shallwani, Hakeem Shakir, Paul M. Foreman, Justin M. Moore, Adam A. Dmytriw, Raghav Gupta, Adnan H. Siddiqui, Elad I. Levy, Kenneth Snyder, Mark R. Harrigan, Christopher S. Ogilvy, Ajith J. Thomas
    World Neurosurgery 2017 105
  • Carotid cavernous fistula after Pipeline placement: a single-center experience and review of the literature
    Anil K Roy, Jonathan A Grossberg, Joshua W Osbun, Susana L Skukalek, Brian M Howard, Faiz U Ahmad, Frank Tong, Jacques E Dion, Charles M Cawley
    Journal of NeuroInterventional Surgery 2017 9 2
  • Single-stage flow diversion with adjunctive coiling for cerebral aneurysm: outcomes and technical considerations in 72 cases
    Matthew T Bender, Bowen Jiang, Jessica K Campos, Li-Mei Lin, Narlin Beaty, Chau D Vo, David A Zarrin, Justin M Caplan, Judy Huang, Rafael J Tamargo, Geoffrey P Colby, Alexander L Coon
    Journal of NeuroInterventional Surgery 2018 10 9
  • Blood Flow Diversion as a Primary Treatment Method for Ruptured Brain Aneurysms—Concerns, Controversy, and Future Directions
    Brian P. Walcott, Matthew J. Koch, Christopher J. Stapleton, Aman B. Patel
    Neurocritical Care 2017 26 3

More in this TOC Section

  • Partial (SAVE) versus Complete (Solumbra) Stent Retriever Retraction Technique for Mechanical Thrombectomy: A Randomized In Vitro Study
  • Contrast Injection from an Intermediate Catheter Placed in an Intradural Artery is Associated with Contrast-Induced Encephalopathy following Neurointervention
  • CT Perfusion Does Not Modify the Effect of Reperfusion in Patients with Acute Ischemic Stroke Undergoing Endovascular Treatment in the ESCAPE-NA1 Trial
Show more INTERVENTIONAL

Similar Articles

Advertisement

News and Updates

  • Lucien Levy Best Research Article Award
  • Thanks to our 2022 Distinguished Reviewers

Resources

  • Evidence-Based Medicine Level Guide
  • AJNR Podcast Archive
  • Librarian Resources
  • Terms and Conditions

Opportunities

  • Get Peer Review Credit from Publons

American Society of Neuroradiology

  • Neurographics
  • ASNR Annual Meeting
  • Fellowship Portal

© 2023 by the American Society of Neuroradiology | Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire