Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Publication Preview--Ahead of Print
    • Past Issue Archive
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
    • COVID-19 Content and Resources
  • For Authors
  • About Us
    • About AJNR
    • Editors
    • American Society of Neuroradiology
  • Submit a Manuscript
  • Podcasts
    • Subscribe on iTunes
    • Subscribe on Stitcher
  • More
    • Subscribers
    • Permissions
    • Advertisers
    • Alerts
    • Feedback
  • Other Publications
    • ajnr

User menu

  • Subscribe
  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

  • Subscribe
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Publication Preview--Ahead of Print
    • Past Issue Archive
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
    • COVID-19 Content and Resources
  • For Authors
  • About Us
    • About AJNR
    • Editors
    • American Society of Neuroradiology
  • Submit a Manuscript
  • Podcasts
    • Subscribe on iTunes
    • Subscribe on Stitcher
  • More
    • Subscribers
    • Permissions
    • Advertisers
    • Alerts
    • Feedback
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds
Research ArticleInterventional

Fast Stent Retrieval Improves Recanalization Rates of Thrombectomy: Experimental Study on Different Thrombi

S. Soize, L. Pierot, M. Mirza, G. Gunning, M. Gilvarry, M. Gawlitza, D. Vivien, M. Zuber and E. Touzé
American Journal of Neuroradiology June 2020, 41 (6) 1049-1053; DOI: https://doi.org/10.3174/ajnr.A6559
S. Soize
aFrom the Department of Neuroradiology (S.S., L.P., M. Gawlitza), Hôpital Maison Blanche, Champagne-Ardenne University, Reims, France
bUnité Mixte de Recherche (UMR)-S 1237 Physiopathology and Imaging of Neurological Disorders (S.S., D.V., E.T.), National Institute for Health and Medical Research, Normandie University, Université Caen Normandie, Cyceron, Caen, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for S. Soize
L. Pierot
aFrom the Department of Neuroradiology (S.S., L.P., M. Gawlitza), Hôpital Maison Blanche, Champagne-Ardenne University, Reims, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for L. Pierot
M. Mirza
cNeuravi/Cerenovus (M.M., G.G., M. Gilvarry), Galway, Ireland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for M. Mirza
G. Gunning
cNeuravi/Cerenovus (M.M., G.G., M. Gilvarry), Galway, Ireland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for G. Gunning
M. Gilvarry
cNeuravi/Cerenovus (M.M., G.G., M. Gilvarry), Galway, Ireland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for M. Gilvarry
M. Gawlitza
aFrom the Department of Neuroradiology (S.S., L.P., M. Gawlitza), Hôpital Maison Blanche, Champagne-Ardenne University, Reims, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for M. Gawlitza
D. Vivien
bUnité Mixte de Recherche (UMR)-S 1237 Physiopathology and Imaging of Neurological Disorders (S.S., D.V., E.T.), National Institute for Health and Medical Research, Normandie University, Université Caen Normandie, Cyceron, Caen, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for D. Vivien
M. Zuber
dDepartment of Neurology (M.Z.), Hôpital Saint-Joseph, Paris Descartes University, Paris, France.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for M. Zuber
E. Touzé
bUnité Mixte de Recherche (UMR)-S 1237 Physiopathology and Imaging of Neurological Disorders (S.S., D.V., E.T.), National Institute for Health and Medical Research, Normandie University, Université Caen Normandie, Cyceron, Caen, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for E. Touzé
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • References
  • PDF
Loading

Abstract

BACKGROUND AND PURPOSE: About 20% of patients with acute ischemic stroke due to large-artery occlusion do not achieve recanalization with mechanical thrombectomy. We aimed to determine whether the speed of retrieval of the stent retriever influences the efficacy in removing different clot types.

MATERIALS AND METHODS: Sixty mechanical thrombectomies were performed using an in vitro pulsatile cerebrovascular circulation model with controlled pressure and flow rate. Experiments were dichotomized into fast and slow retrieval using a wedging technique, in which the stent retriever and distal catheter are retrieved together. We used 3 different clot types: erythrocyte-rich, fibrin-rich, and friable clots. Primary end points were complete (TICI 3) and successful (TICI 2b–3) recanalizations. Secondary measures were distal and new territory embolizations.

RESULTS: Fast retrieval was more frequently associated with complete (RR = 1.83; 95% CI, 1.12–2.99) and successful recanalization (RR = 1.50; 95% CI, 1.03–2.19) than slow retrieval, without a difference in distal embolization (RR = 0.75; 95% CI, 0.29–1.90). There were no emboli in a new territory. The advantage of fast retrieval over slow retrieval differed according to the clot composition, with a stronger effect with fibrin-rich clots with regard to complete (RR = 4.00; 95% CI, 1.11–14.35; Pint = .04) and successful (Pint = .10) recanalization.

CONCLUSIONS: In our experimental model, a fast removal improved recanalization rates of mechanical thrombectomy, especially in the case of fibrin-rich clots. An in vivo confirmation is warranted to see whether our findings can have an impact in clinical practice.

ABBREVIATIONS:

DC
distal catheter
MT
mechanical thrombectomy
RR
relative risk
Pint
P interaction
RBC
red blood cell
SR
stent retriever

Mechanical thrombectomy (MT) is considered the first-line therapy for selected patients with acute ischemic stroke with a proximal cerebral artery occlusion.1⇓-3 The dramatic technological improvements, such as the combined use of stent retrievers (SRs) and distal catheters (DCs), have led to recanalization rates unreached before.4,5 With the goal of increasing clot entrapment, techniques in which the thrombus is wedged between the SR and DC have become more popular.6⇓-8 Nevertheless, a successful recanalization is still not obtained in around 20% of patients.9 Potential issues may arise from the retrieval technique itself, the interactions between device-thrombus, and the clot composition.9,10 To date, only a few experimental studies have investigated th1053e interaction of the SR with artificial thrombi,11⇓⇓⇓⇓⇓⇓-18 and the influence of the retrieval speed on MT success has never been explored. The most instinctive approach to remove an SR is to pull it back slowly to save the vessel from potential damage and the clot from breaking.5,9 However, a fast removal can mobilize the clot suddenly and allow application of higher pulling force to enhance wedging. We aimed to determine whether the speed of retrieval influences the efficacy in removing clots.

MATERIALS AND METHODS

Study Setting

Using an in vitro model of cerebrovascular occlusion, we performed a total of 60 thrombectomy experiments (1 pass only for each), dichotomized into 2 groups according to the speed of retrieval of the SR-DC unit (fast or slow retrieval). The experiments were performed with 3 types of clots. Half of the tests were performed with Solitaire 2 (4 × 20 mm) (Medtronic) and half with Embotrap II (5 × 21 mm) (Neuravi/Cerenovus). Consequently, there were 2 speeds × 3 types of clots × 5 maneuvers each × 2 devices, corresponding to 60 MTs in total.

Flow Model

In brief, the model is made of silicone channels (Elastrat) mimicking the human anterior intracranial circulation. The flow model had sharp angles and large perforator diameters to create challenging conditions, and a posterior flow was also added for complete circle of Willis flow. A saline solution at 37°C was pumped through the model with a 430-mL/min flow rate and 110/60 mm Hg pulsatile pressure. A fresh clot was introduced into the model to simulate the vessel occlusion (Fig 1).

Fig 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 1.

Flow model.

Clots Types

We used 3 different types of clot depending on their composition (Fig 2): red blood cell (RBC)-rich, fibrin-rich, and hybrid clots (representing the challenges of a friable clot). The RBC-rich clots were formed from whole ovine blood by allowing the blood to clot spontaneously. The fibrin-rich clots were prepared by first spinning down the blood sample in a centrifuge and recombining 5% RBCs with 95% plasma to produce a fibrin-rich clot.19 Hybrid clots were prepared specifically to represent the challenges of friable clots. They were prepared by cutting spontaneously formed clot (RBC-rich) into 1- to 1.5-mm cubes. Ten of these cubes were inserted into a 2.5-mm diameter silicone tube where they were lightly glued together with a mixture of blood and thrombin. Once the mixture was fully set (30 minutes), the hybrid clot was carefully removed from the silicone tube. The size of all clot types was standardized at a 2.5- mm diameter by 10-mm length. Clots were introduced into the model and navigated into the M1 or M2 MCA segment using the anterograde flow of the circulating fluid. A 3-minute embedding time was respected.

Fig 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 2.

Clot types. The figure shows the 3 types of clot during MT inside the model: RBC-rich (left), fibrin-rich (middle), and hybrid friable clot (right).

Thrombectomy Technique

MT consisted of a microcatheter (Rebar-18; Medtronic) navigated through a distal catheter (Sofia Plus; MicroVention), which was advanced into a guide catheter (Neuron Max; Penumbra). We used 0.014-inch microwires (Traxcess 14; MicroVention) to cross the thrombus. The proximal third to half of the stent retriever was deployed across the clot. Thereafter, the DC was advanced into the proximal M1, and the microcatheter was withdrawn inside the DC. After 3 minutes, the SR was retrieved until half was inside the DC or until resistance was felt. Then, the system was retrieved completely as a single unit (SR + DC + microcatheter) with a continuous movement.7,8 No suction was applied during removal. A fast retrieval was performed in 5 seconds maximum, and a slow retrieval, in 15 seconds minimum. To ensure reproducibility, we performed 10 training experiments before starting the study. The speed was calculated by dividing the time (measured by an assistant with a stopwatch) by the distance (measured from the guide catheter tip to the proximal limit of the thrombus with a flexible meter). The MT result was instantly graded by the performing physician according to an adapted TICI score: complete recanalization (TICI 3), recanalization with small emboli exceeding the model limits (TICI 2b), recanalization but emboli blocked distally (TICI 2a), a piece of thrombus removed but persistent occlusion (TICI 1), and no recanalization (TICI 0). Distal emboli corresponded to part of the initial thrombus migrating in the MCA territory farther than the distal limit of the model (ie, <1.5 mm in diameter). Emboli in a new territory were any clots migrating into another area. Primary outcome measures were complete (TICI 3) and successful recanalization (TICI 2b–3). Secondary measures were distal and new territory emboli. All experiments were recorded and reviewed for verification purposes (On-line Videos).

Statistical Analyses

Distribution normality was assessed using the Kolmogorov-Smirnov test. Continuous variables were described as mean ± SD or median and interquartile range and were compared using the Student t test or Mann-Whitney U test. Categoric variables were presented as counts and compared using the χ2 or Fisher exact test. Relative risks and their 95% confidence intervals were calculated. Interaction analyses were performed using the Cochran-Mantel-Haenszel test. Analyses were performed using STATA software (Realease 15.0; StataCorp).

RESULTS

Fast-versus-Slow Retrieval

The mean time of retrieval was 2.4 ± 1.2 seconds in the fast group and 27.3 ± 6.8 seconds in the slow group (P < .001). Overall, fast retrieval led to higher rates of complete (73% versus 40%, P = .01) and successful (80% versus 53%, P = .03) first-pass recanalization than slow retrieval. Fast retrieval was more frequently associated with complete (Relative Risk = 1.83; 95% CI, 1.12–2.99) and successful first-pass recanalization (RR = 1.50; 95% CI, 1.03–2.19) than slow retrieval. Recanalization rates in the whole experiment as well as according to clot type and SR type are shown in Fig 3.

Fig 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 3.

Complete (A) and successful (B) recanalization rates.

Clot Composition

The advantage of fast retrieval over slow retrieval differed according to the clot composition (Fig 4), with a stronger effect obtained with fibrin-rich clots (RR = 4.00; 95% CI, 1.11–14.35) than with RBC-rich (RR = 1.25; 95% CI, 0.92–1.70) and hybrid friable (RR = 2.00; 95% CI, 0.47–8.56) clots with regard to complete recanalization (Pint = .04). This result was similar when considering successful recanalization instead (Pint = .10) (Fig 2).

Fig 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 4.

Interactions analyses. Interaction between the speed of retrieval and the clot type with regard to complete (A) and successful (B) recanalization. Interaction between the speed of retrieval and stent retriever type with regard to complete (C) and successful (D) recanalization.

SR Type

The advantage of fast retrieval over slow retrieval did not differ according to the SR type (Fig 2) with regard to complete recanalization (Pint = .32) or successful recanalization (Pint = .19) (Fig 4).

Distal Embolization

Distal embolization occurred only with hybrid friable clots and was not different between fast (20.0%) and slow (26.7%) retrieval groups (RR = 0.75; 95% CI, 0.29–1.90). There were no emboli in a new territory.

DISCUSSION

Our experimental study showed that a fast retrieval improves recanalization rates, without increasing the rate of distal embolization. It was all the more important that we measured the achievement of complete/successful revascularization after 1 pass, which is associated with significantly higher rates of good clinical outcome.20⇓-22 In this experimental study, we reached 73% and 80% of complete and successful recanalization with 1 pass, while in clinical routine, current thrombectomy techniques yield around 30% and 50% complete and successful recanalization, respectively.20⇓-22 Although not instinctive, a fast removal can mobilize the clot suddenly, allow application of higher pulling force, enhance clot wedging, and minimize loss of apposition during the path of retrieval. Also, it may leave less time for variations of the pulling force, hence avoiding undesired loss of contact between SR and DC. A fast removal did not modify the rate of distal embolization, probably because of an active pinning of the whole thrombus length.

While fast retrieval seems promising in terms of recanalization, an important concern is the clinical safety of this technique. Indeed, human perforating arteries cannot be modeled accurately, and the risk of injury remains unknown. The manufacturers recommend slowly withdrawing the SR as a precaution for safety. When one performs a mechanical retrieval, the perforators may be exposed to excessive force due to stretching and may be rarely sheared off, leading to extravasation. A sudden mobilization of the clot may enhance its retrieval, but the effect on the lenticulostriate arteries is unknown. Thus, the safety of fast retrieval needs to be evaluated in vivo.

The composition and physical properties of the clot can play a key role in the response to MT.9,23⇓-25 We observed a stronger advantage of fast over slow retrieval with fibrin-rich clots. These clots probably account for a large part of MT failures because they are firm and sticky.9,23,24 Fast retrieval, by mobilizing the clot suddenly, may have contributed to better clot trapping. Because imaging features of fibrin-rich thrombi are correlated with decreased revascularization rates,25,26 a fast retrieval might be recommended in such cases, to enhance first-pass revascularization. This is all the more important in that there is the potential for thrombus compression and increasing difficulty of subsequent retrieval after each thrombectomy attempt.9

Our study has potential limitations. First, the model and clots were more representative of embolic stroke types (not atherosclerosis). The circulation model does not fully simulate the human artery, and further in vivo studies are mandatory to confirm our results and evaluate the clinical safety. Also, tortuous anatomy probably has an impact that cannot be measured with our model.22 Second, because we aimed to analyze only factors attributable to the SR, we did not apply aspiration. In all the in vitro attempts, the DC was always in the M1 proximal part, covering the anterior cerebral artery and in the same axis as the clot. In such cases, the need for proximal aspiration was probably less important than when clot and DC are far away from each other (eg, distal M2 clot, or DC still in the ICA) or in a very tortuous M1. Because only 1 specific procedural setup was simulated, it may not translate to other procedures (longer clots, techniques not similar to Aspiration-Retriever Technique for Stroke or stent-assisted vacuum-locked extraction (SAVE technique), and use of a baloon guide catheter). Such setups remain to be tested.

CONCLUSIONS

In our experimental model, a fast removal improved recanalization rates of MT, especially in case of fibrin-rich clots, which are known to be challenging to remove. An in vivo confirmation is warranted to see whether our findings can impact clinical practice.

Footnotes

  • Disclosures: Laurent Pierot—UNRELATED: Consultancy: Balt, MicroVention, phenox, Vesalio. Mahmood Mirza—UNRELATED: Employment: Cerenovus; Stock/Stock Options: Cerenovus. Matthias Gawlitza—UNRELATED: Expert Testimony: MicroVention, Comments: member of the Clinical Event Committee for a company-initiated study on a neurovascular device; Travel/Accommodations/Meeting Expenses Unrelated to Activities Listed: Neuravi/Cerenovus, phenox, MicroVention, Comments: travel and accommodations for training workshops of the respective companies; Other: Lin. Michael Gilvarry—UNRELATED: Employment: Cerenovus; Stock/Stock Options: Cerenovus.

References

  1. 1.↵
    1. Powers WJ,
    2. Rabinstein AA,
    3. Ackerson T, et al
    ; American Heart Association Stroke Council. 2018 Guidelines for the Early Management of Patients with Acute Ischemic Stroke: a Guideline for Healthcare Professionals From the American Heart Association/American Stroke Association. Stroke 2018;49:e46–10 doi:10.1161/STR.0000000000000158 pmid:29367334
    Abstract/FREE Full Text
  2. 2.↵
    1. Mokin M,
    2. Ansari SA,
    3. McTaggart RA, et al
    ; Society of NeuroInterventional Surgery. Indications for thrombectomy in acute ischemic stroke from emergent large vessel occlusion (ELVO): report of the SNIS Standards and Guidelines Committee. J Neurointerv Surg 2019;11:215–20 doi:10.1136/neurintsurg-2018-014640 pmid:30610069
    FREE Full Text
  3. 3.↵
    1. Gandhi CD,
    2. Al Mufti F,
    3. Singh IP, et al
    ; Standards and Guidelines committee of the Society of NeuroInterventional Surgery (SNIS). Neuroendovascular management of emergent large vessel occlusion: update on the technical aspects and standards of practice by the Standards and Guidelines Committee of the Society of NeuroInterventional Surgery. J Neurointerv Surg 2018;10:315–20 doi:10.1136/neurintsurg-2017-013554 pmid:29326380
    FREE Full Text
  4. 4.↵
    1. Goyal M,
    2. Menon BK,
    3. van Zwam WH, et al
    . Endovascular thrombectomy after large-vessel ischaemic stroke: a meta-analysis of individual patient data from five randomised trials. Lancet 2016;387:1723–31 doi:10.1016/S0140-6736(16)00163-X pmid:26898852
    CrossRefPubMed
  5. 5.↵
    1. Pierot L,
    2. Soize S,
    3. Benaissa A, et al
    . Techniques for endovascular treatment of acute ischemic stroke: from intra-arterial fibrinolytics to stent-retrievers. Stroke 2015;46:909–14 doi:10.1161/STROKEAHA.114.007935 pmid:25657185
    FREE Full Text
  6. 6.↵
    1. Mokin M,
    2. Ionita CN,
    3. Nagesh SV, et al
    . Primary stentriever versus combined stentriever plus aspiration thrombectomy approaches: in vitro stroke model comparison. J Neurointerv Surg 2015;7:453–57 doi:10.1136/neurintsurg-2014-011148 pmid:24789594
    Abstract/FREE Full Text
  7. 7.↵
    1. Massari F,
    2. Henninger N,
    3. Lozano JD, et al
    . ARTS (Aspiration-Retriever Technique for Stroke): initial clinical experience. Interv Neuroradiol 2016;22:325–32 doi:10.1177/1591019916632369 pmid:26908591
    CrossRefPubMed
  8. 8.↵
    1. Maus V,
    2. Behme D,
    3. Kabbasch C, et al
    . Maximizing first-pass complete reperfusion with SAVE. Clin Neuroradiol 2018;28:327–38 doi:10.1007/s00062-017-0566-z pmid:28194477
    CrossRefPubMed
  9. 9.↵
    1. Yoo AJ,
    2. Andersson T
    . Thrombectomy in acute ischemic stroke: challenges to procedural success. J Stroke 2017;19:121–30 doi:10.5853/jos.2017.00752 pmid:28592779
    CrossRefPubMed
  10. 10.↵
    1. Kaesmacher J,
    2. Gralla J,
    3. Mosimann PJ, et al
    . Reasons for reperfusion failures in stent-retriever-based thrombectomy: registry analysis and proposal of a classification system. AJNR Am J Neuroradiol 2018;39:1848–53 doi:10.3174/ajnr.A5759 pmid:30166434
    Abstract/FREE Full Text
  11. 11.↵
    1. Gralla J,
    2. Schroth G,
    3. Remonda L, et al
    . Mechanical thrombectomy for acute ischemic stroke thrombus-device interaction, efficiency, and complications in vivo. Stroke 2006;37:3019–24 doi:10.1161/01.STR.0000248457.55493.85 pmid:17053185
    Abstract/FREE Full Text
  12. 12.↵
    1. Chueh JY,
    2. Wakhloo AK,
    3. Gounis MJ
    . Effectiveness of mechanical endovascular thrombectomy in a model system of cerebrovascular occlusion. AJNR Am J Neuroradiol 2012;33:1998–2003 doi:10.3174/ajnr.A3103 pmid:22555570
    Abstract/FREE Full Text
  13. 13.↵
    1. Wenger KJ,
    2. Nagl F,
    3. Wagner M, et al
    . Improvement of stent retriever design and efficacy of mechanical thrombectomy in a flow model. Cardiovasc Intervent Radiol 2013;36:192–97 doi:10.1007/s00270-012-0420-2 pmid:22699778
    CrossRefPubMed
  14. 14.↵
    1. Mordasini P,
    2. Brekenfeld C,
    3. Byrne J, et al
    . Experimental evaluation of immediate recanalization effect and recanalization efficacy of a new thrombus retriever for acute stroke treatment in vivo. AJNR Am J Neuroradiol 2013;34:153–58 doi:10.3174/ajnr.A3275 pmid:22837308
    Abstract/FREE Full Text
  15. 15.↵
    1. Mokin M,
    2. Setlur Nagesh SV,
    3. Ionita CN, et al
    . Comparison of modern stroke thrombectomy approaches using an in vitro cerebrovascular occlusion model. AJNR Am J Neuroradiol 2015;36:547–51 doi:10.3174/ajnr.A4149 pmid:25376809
    Abstract/FREE Full Text
  16. 16.↵
    1. Madjidyar J,
    2. Hermes J,
    3. Freitag-Wolf S, et al
    . Stent-thrombus interaction and the influence of the aspiration on mechanical thrombectomy: evaluation of different stent retrievers in a circulation model. Neuroradiology 2015;57:791–97 doi:10.1007/s00234-015-1526-4 pmid:25903428
    CrossRefPubMed
  17. 17.↵
    1. van der Marel K,
    2. Chueh JY,
    3. Brooks OW, et al
    . Quantitative assessment of device-clot interaction for stent retriever thrombectomy. J Neurointerv Surg 2016;8:1278–82 doi:10.1136/neurintsurg-2015-012209 pmid:26833539
    Abstract/FREE Full Text
  18. 18.↵
    1. Machi P,
    2. Jourdan F,
    3. Ambard D, et al
    . Experimental evaluation of stent retrievers’ mechanical properties and effectiveness. J Neurointerv Surg 2017;9:257–63 doi:10.1136/neurintsurg-2015-012213 pmid:27016318
    Abstract/FREE Full Text
  19. 19.↵
    1. Duffy S,
    2. Farrell M,
    3. McArdle K, et al
    . Novel methodology to replicate clot analogs with diverse composition in acute ischemic stroke. J Neurointerv Surg 2017;9:486–91 doi:10.1136/neurintsurg-2016-012308 pmid:27127231
    Abstract/FREE Full Text
  20. 20.↵
    1. Zaidat OO,
    2. Castonguay AC,
    3. Linfante I, et al
    . First pass effect: a new measure for stroke thrombectomy devices. Stroke 2018;49:660–66 doi:10.1161/STROKEAHA.117.020315 pmid:29459390
    Abstract/FREE Full Text
  21. 21.↵
    1. Ducroux C,
    2. Piotin M,
    3. Gory B, et al
    . First pass effect with contact aspiration and stent retrievers in the Aspiration versus Stent Retriever (ASTER) trial. J Neurointerv Surg 2020;12:386–91 doi:10.1136/neurintsurg-2019-015215 pmid:31471527
    Abstract/FREE Full Text
  22. 22.↵
    1. Srivatsa S,
    2. Duan Y,
    3. Sheppard JP, et al
    . Cerebral vessel anatomy as a predictor of first-pass effect in mechanical thrombectomy for emergent large-vessel occlusion. J Neurosurg 2020 Jan 24. [Epub ahead of print] doi:10.3171/2019.11.JNS192673 pmid:31978878
    CrossRefPubMed
  23. 23.↵
    1. Yuki I,
    2. Kan I,
    3. Vinters HV, et al
    . The impact of thromboemboli histology on the performance of a mechanical thrombectomy device. AJNR Am J Neuroradiol 2012;33:643–48 doi:10.3174/ajnr.A2842 pmid:22207297
    Abstract/FREE Full Text
  24. 24.↵
    1. Gunning GM,
    2. McArdle K,
    3. Mirza M, et al
    . Clot friction variation with fibrin content; implications for resistance to thrombectomy. J NeuroIntervent Surg 2018;10:34–38 doi:10.1136/neurintsurg-2016-012721 pmid:28044009
    Abstract/FREE Full Text
  25. 25.↵
    1. Lövblad KO
    . Targeting the clot in acute stroke. AJNR Am J Neuroradiol 2018;39:E77 doi:10.3174/ajnr.A5600 pmid:29519790
    FREE Full Text
  26. 26.↵
    1. Brinjikji W,
    2. Duffy S,
    3. Burrows A, et al
    . Correlation of imaging and histopathology of thrombi in acute ischemic stroke with etiology and outcome: a systematic review. J Neurointerv Surg 2017;9:529–34 doi:10.1136/neurintsurg-2016-012391 pmid:27166383
    Abstract/FREE Full Text
  • Received January 17, 2020.
  • Accepted after revision March 2, 2020.
  • © 2020 by American Journal of Neuroradiology
View Abstract
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 41 (6)
American Journal of Neuroradiology
Vol. 41, Issue 6
1 Jun 2020
  • Table of Contents
  • Index by author
  • Complete Issue (PDF)
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Fast Stent Retrieval Improves Recanalization Rates of Thrombectomy: Experimental Study on Different Thrombi
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Fast Stent Retrieval Improves Recanalization Rates of Thrombectomy: Experimental Study on Different Thrombi
S. Soize, L. Pierot, M. Mirza, G. Gunning, M. Gilvarry, M. Gawlitza, D. Vivien, M. Zuber, E. Touzé
American Journal of Neuroradiology Jun 2020, 41 (6) 1049-1053; DOI: 10.3174/ajnr.A6559

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Fast Stent Retrieval Improves Recanalization Rates of Thrombectomy: Experimental Study on Different Thrombi
S. Soize, L. Pierot, M. Mirza, G. Gunning, M. Gilvarry, M. Gawlitza, D. Vivien, M. Zuber, E. Touzé
American Journal of Neuroradiology Jun 2020, 41 (6) 1049-1053; DOI: 10.3174/ajnr.A6559
Reddit logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • Abstract
    • ABBREVIATIONS:
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSIONS
    • Footnotes
    • References
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • References
  • PDF

Related Articles

  • PubMed
  • Google Scholar

Cited By...

  • Fast Stent Retrieval during Mechanical Thrombectomy Improves Recanalization in Patients with the Negative Susceptibility Vessel Sign
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

More in this TOC Section

  • The FRESH Study: Treatment of Intracranial Aneurysms with the New FRED X Flow Diverter with Antithrombotic Surface Treatment Technology—First Multicenter Experience in 161 Patients
  • Aneurysm Treatment with Woven EndoBridge-17: Angiographic and Clinical Results at 12 Months from a Retrospective, 2-Center Series
  • Malpractice Litigation Related to Diagnosis and Treatment of Intracranial Aneurysms
Show more INTERVENTIONAL

Similar Articles

Advertisement

News and Updates

  • Lucien Levy Best Research Article Award
  • Thanks to our 2022 Distinguished Reviewers
  • Press Releases

Resources

  • Evidence-Based Medicine Level Guide
  • How to Participate in a Tweet Chat
  • AJNR Podcast Archive
  • Ideas for Publicizing Your Research
  • Librarian Resources
  • Terms and Conditions

Opportunities

  • Share Your Art in Perspectives
  • Get Peer Review Credit from Publons
  • Moderate a Tweet Chat

American Society of Neuroradiology

  • Neurographics
  • ASNR Annual Meeting
  • Fellowship Portal
  • Position Statements

© 2023 by the American Society of Neuroradiology | Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire