Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Publication Preview--Ahead of Print
    • Past Issue Archive
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
    • COVID-19 Content and Resources
  • For Authors
  • About Us
    • About AJNR
    • Editors
    • American Society of Neuroradiology
  • Submit a Manuscript
  • Podcasts
    • Subscribe on iTunes
    • Subscribe on Stitcher
  • More
    • Subscribers
    • Permissions
    • Advertisers
    • Alerts
    • Feedback
  • Other Publications
    • ajnr

User menu

  • Subscribe
  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

  • Subscribe
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Publication Preview--Ahead of Print
    • Past Issue Archive
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
    • COVID-19 Content and Resources
  • For Authors
  • About Us
    • About AJNR
    • Editors
    • American Society of Neuroradiology
  • Submit a Manuscript
  • Podcasts
    • Subscribe on iTunes
    • Subscribe on Stitcher
  • More
    • Subscribers
    • Permissions
    • Advertisers
    • Alerts
    • Feedback
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds
Research ArticlePediatrics

Diagnostic Utility of 3D Gradient-Echo MR Imaging Sequences through the Filum Compared with Spin-Echo T1 in Children with Concern for Tethered Cord

F. Rafiee, W.A. Mehan, S. Rincon, S. Rohatgi, O. Rapalino and K. Buch
American Journal of Neuroradiology March 2023, 44 (3) 323-327; DOI: https://doi.org/10.3174/ajnr.A7791
F. Rafiee
aFrom the Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for F. Rafiee
W.A. Mehan
aFrom the Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for W.A. Mehan
S. Rincon
aFrom the Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for S. Rincon
S. Rohatgi
aFrom the Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for S. Rohatgi
O. Rapalino
aFrom the Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for O. Rapalino
K. Buch
aFrom the Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for K. Buch
  • Article
  • Figures & Data
  • Info & Metrics
  • References
  • PDF
Loading

This article requires a subscription to view the full text. If you have a subscription you may use the login form below to view the article. Access to this article can also be purchased.

Abstract

BACKGROUND AND PURPOSE: Fatty intrathecal lesions are a cause of tethered cord, and detection of these on spinal MR imaging is paramount. Conventional T1 FSE sequences are the mainstay of detecting fatty elements; however, 3D gradient-echo MR images, volumetric interpolated breath-hold examination/liver acquisition with volume acceleration (VIBE/LAVA), are popular, given the increased motion resistance. We sought to evaluate the diagnostic accuracy of VIBE/LAVA compared with T1 FSE for detection of fatty intrathecal lesions.

MATERIALS AND METHODS: In this retrospective, institutional review board–approved study, 479 consecutive pediatric spine MRIs obtained to evaluate cord tethering between January 2016 and April 2022 were reviewed. Inclusion criteria were patients who were 20 years of age or younger who underwent spine MRIs containing both axial T1 FSE and VIBE/LAVA sequences of the lumbar spine. The presence or absence of fatty intrathecal lesions was recorded for each sequence. If fatty intrathecal lesions were present, anterior-posterior and transverse dimensions were recorded. VIBE/LAVA and T1 FSE sequences were evaluated on 2 separate occasions (VIBE/LAVAs first followed by T1 FSE several weeks later) to minimize bias. Basic descriptive statistics compared fatty intrathecal lesion sizes on T1 FSEs and VIBE/LAVAs. Receiver operating characteristic curves were used to determine minimal fatty intrathecal lesion size detectable by VIBE/LAVA.

RESULTS: Sixty-six patients were included, with 22 having fatty intrathecal lesions (mean age, 7.2 years). T1 FSE sequences revealed fatty intrathecal lesions in 21/22 cases (95%); however, fatty intrathecal lesions on VIBE/LAVA were detected in 12/22 patients (55%). Mean anterior-posterior and transverse dimensions of fatty intrathecal lesions measured larger on T1 FSE compared with VIBE/LAVA sequences (5.4 × 5.0 mm versus 1.5 × 1.6 mm, respectively; P values = .039 anterior-posterior; .027 transverse).

CONCLUSIONS: While T1 3D gradient-echo MR images may have decreased the acquisition time and are more motion-resistant than conventional T1 FSE sequences, they are less sensitive and may miss small fatty intrathecal lesions.

ABBREVIATIONS:

AP
anterior-posterior
FIL
fatty intrathecal lesion
LAVA
liver acquisition with volume acceleration
RL
transverse
ROC
receiver operating characteristic
TCS
tethered cord syndrome
VIBE
volumetric interpolated breath-hold examination
  • © 2023 by American Journal of Neuroradiology
View Full Text

Log in using your username and password

Forgot your user name or password?
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 44 (3)
American Journal of Neuroradiology
Vol. 44, Issue 3
1 Mar 2023
  • Table of Contents
  • Index by author
  • Complete Issue (PDF)
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Diagnostic Utility of 3D Gradient-Echo MR Imaging Sequences through the Filum Compared with Spin-Echo T1 in Children with Concern for Tethered Cord
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Diagnostic Utility of 3D Gradient-Echo MR Imaging Sequences through the Filum Compared with Spin-Echo T1 in Children with Concern for Tethered Cord
F. Rafiee, W.A. Mehan, S. Rincon, S. Rohatgi, O. Rapalino, K. Buch
American Journal of Neuroradiology Mar 2023, 44 (3) 323-327; DOI: 10.3174/ajnr.A7791

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Diagnostic Utility of 3D Gradient-Echo MR Imaging Sequences through the Filum Compared with Spin-Echo T1 in Children with Concern for Tethered Cord
F. Rafiee, W.A. Mehan, S. Rincon, S. Rohatgi, O. Rapalino, K. Buch
American Journal of Neuroradiology Mar 2023, 44 (3) 323-327; DOI: 10.3174/ajnr.A7791
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • Abstract
    • ABBREVIATIONS:
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSIONS
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • References
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

More in this TOC Section

  • Exploratory Multisite Magnetic Resonance Spectroscopic Imaging Shows White Matter Neuroaxonal Loss Associated with Complications of Type 1 Diabetes in Children
  • Doppler Ultrasound Flow Reversal in the Superior Sagittal Sinus to Detect Cerebral Venous Congestion in Vein of Galen Malformation
  • Subarachnoid Space Measurements in Apparently Healthy Fetuses Using MR Imaging
Show more PEDIATRICS

Similar Articles

Advertisement

News and Updates

  • Lucien Levy Best Research Article Award
  • Thanks to our 2022 Distinguished Reviewers
  • Press Releases

Resources

  • Evidence-Based Medicine Level Guide
  • How to Participate in a Tweet Chat
  • AJNR Podcast Archive
  • Ideas for Publicizing Your Research
  • Librarian Resources
  • Terms and Conditions

Opportunities

  • Share Your Art in Perspectives
  • Get Peer Review Credit from Publons
  • Moderate a Tweet Chat

American Society of Neuroradiology

  • Neurographics
  • ASNR Annual Meeting
  • Fellowship Portal
  • Position Statements

© 2023 by the American Society of Neuroradiology | Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire