This article requires a subscription to view the full text. If you have a subscription you may use the login form below to view the article. Access to this article can also be purchased.
Abstract
BACKGROUND AND PURPOSE: Reliable preoperative visualization of facial nerve morphology and understanding the spatial relationship between the facial nerve and tumors in the parotid gland can help clinicians perform safe and effective surgeries. Hence, this study aimed to compare the image quality of extracranial facial nerves obtained by using double-echo steady state with water excitation (DESS-WE) and CISS sequences and evaluate their diagnostic efficacy in the localization of parotid tumors.
MATERIALS AND METHODS: In total, 32 facial nerves of 16 healthy volunteers and 25 facial nerves of 25 patients with parotid tumors were included in this retrospective study. All participants underwent noncontrast-enhanced extracranial facial nerve MR imaging with DESS-WE and CISS with a 3T MR scanner equipped with a 64-channel head and neck coil. Image quality was subjectively evaluated by using a 5-point Likert scale by 2 radiologists. Inter- and intrarater agreements were assessed by using the Cohen κ coefficient. Receiver operating characteristic analysis was performed, and the diagnostic efficacies of DESS-WE and CISS images in localizing parotid tumors were calculated.
RESULTS: For healthy volunteers (11 men and 5 women; median age, 26 years), image quality scores for CISS were significantly higher than those for DESS-WE for the discrimination of the temporofacial and cervicofacial trunks (both, P < .001). In patients with parotid tumors (12 men and 13 women; median age, 58 years), CISS performed better than DESS-WE in terms of visualizing the spatial relationship of the facial nerve to the tumor and diagnostic confidence (both, P < .001). Regarding the localization of parotid tumors, CISS showed excellent performance, comparable to that of DESS-WE (area under the curve, 0.981 versus 0.942, P = .1489).
CONCLUSIONS: CISS achieved diagnostic performance comparable to DESS-WE in parotid tumor localization, with favorable image quality and more reliable morphologic visualization of the facial nerve.
ABBREVIATIONS:
- CNR
- contrast-to-noise ratio
- DESS-WE
- double-echo steady state with water excitation
- IQS
- image quality score
- IQR
- interquartile range
- © 2024 by American Journal of Neuroradiology