This article requires a subscription to view the full text. If you have a subscription you may use the login form below to view the article. Access to this article can also be purchased.
Abstract
BACKGROUND AND PURPOSE: 7T MRI is a promising clinical technology for epilepsy imaging. Quantification of hippocampus volume on MRI is a clinically useful biomarker in epilepsy. Applying automated hippocampus volume measurement tools to 7T MRI is needed to optimize the use of clinical ultra-high-field strength epilepsy imaging. The objective of this study is a performance evaluation of automated hippocampal volume measurement software at 7T MRI in both normal participants and those with seizure disorders.
MATERIALS AND METHODS: 7T MRI examinations were prospectively acquired in 50 participants. A subset of participants also underwent 3T MRI examinations, and a subset underwent 2 separate 7T acquisitions. Automated segmentation of the hippocampus was performed with 2 commonly used software packages (FreeSurfer and NeuroQuant) at 3T and 7T, with hippocampal volumes calculated for segmentations without any visually unacceptable errors as determined by radiologist review. Hippocampal volumes were also measured from manual segmentations, and the intraclass correlation coefficient (ICC) was used to compare data with automated segmentation volumes.
RESULTS: Visually unacceptable automated hippocampus segmentation errors occurred more frequently at 7T than at 3T with NeuroQuant (11.0% versus 7.14%) and FreeSurfer (12.5% versus 0%). Computerized volume measurements at 7T correlated poorly with manual segmentation for both software programs (ICC <0.4). Hippocampal volume estimate correlation between matched 7T and 3T MRI in the same participant was fair (ICC = 0.4–0.59) to good (0.6–0.75) for software and manual segmentation. For repeated 7T MRI examinations in the same participant, hippocampus segmentation reproducibility was excellent (0.75) for automated software but poor (< 0.4) for manual segmentation.
CONCLUSIONS: Computerized volume measurement of the hippocampus at 7T correlates poorly with volumes obtained through manual segmentation and suboptimally with matched 3T examination measurements, but is highly reproducible at 7T within the same participant. Segmentation errors are more common with 7T examinations, and further development of a hippocampal segmentation method specific to 7T MRI is needed to fully realize the benefits of 7T MRI for imaging patients with epilepsy.
ABBREVIATIONS:
- ASHS
- automatic segmentation of hippocampal subfields
- HA
- hippocampal asymmetry
- ICC
- intraclass correlation coefficient
- MTL
- mesial temporal
- RF
- radiofrequency
Footnotes
Brian Burkett, MD, MPH, and Kirk Welker, MD, received funding from the RSNA R&E Foundation RSNA Presidents Circle Research Resident Grant to support this work. Sonia Watson, PhD, provided editorial assistance with manuscript preparation, funded by the Mayo Clinic Department of Radiology.
Disclosure forms provided by the authors are available with the full text and PDF of this article at www.ajnr.org.
- © 2025 by American Journal of Neuroradiology
ASNR members
Login to the site using your ASNR member credentials