PT - JOURNAL ARTICLE AU - T C Roth AU - J C Chaloupka AU - C M Putman AU - D A Ross AU - E M Weaver AU - J Tarro AU - D M Wecht AU - C T Sasaki TI - Percutaneous direct-puncture acrylic embolization of a pseudoaneurysm after failed carotid stenting for the treatment of acute carotid blowout. DP - 1998 May 01 TA - American Journal of Neuroradiology PG - 912--916 VI - 19 IP - 5 4099 - http://www.ajnr.org/content/19/5/912.short 4100 - http://www.ajnr.org/content/19/5/912.full SO - Am. J. Neuroradiol.1998 May 01; 19 AB - We report a difficult case of recurrent carotid blowout syndrome in a patient who had a rupture of the common carotid artery with formation of a large pseudoaneurysm. Conventional management of this emergency, consisting of composite occlusion of the internal and common carotid arteries, was not possible owing to prior clinical failure of balloon test occlusion. This led to an initial attempt to cover the site of rupture with overlapping self-expanding stents, which was only temporarily successful in controlling the hemorrhage. When a subsequent episode of carotid rupture with life-threatening hemorrhage occurred, percutaneous direct-puncture acrylic embolization with temporary flow arrest was used to successfully obliterate the pseudoaneurysm.