PT - JOURNAL ARTICLE AU - S. Bisdas AU - D.E. Bohning AU - N. Bešenski AU - J.S. Nicholas AU - Z. Rumboldt TI - Reproducibility, Interrater Agreement, and Age-Related Changes of Fractional Anisotropy Measures at 3T in Healthy Subjects: Effect of the Applied b-Value AID - 10.3174/ajnr.A1044 DP - 2008 Jun 01 TA - American Journal of Neuroradiology PG - 1128--1133 VI - 29 IP - 6 4099 - http://www.ajnr.org/content/29/6/1128.short 4100 - http://www.ajnr.org/content/29/6/1128.full SO - Am. J. Neuroradiol.2008 Jun 01; 29 AB - BACKGROUND AND PURPOSE: There is no reproducibility study of fractional anisotropy (FA) measurements at 3T using regions of interest (ROIs). Our purpose was to establish the extent and statistical significance of the interrater variability, the variability observed with 2 different b-values, and in 2 separate scanning sessions.MATERIALS AND METHODS: Twelve healthy volunteers underwent MR imaging twice. MR imaging was performed on a 3T unit, and FA maps were analyzed independently by 2 observers using ROIs positioned in the corpus callosum, internal capsules, corticospinal tracts, and right thalamus. Changes in FA values (×103) measured with 2 b-values (700 and 1000 s/mm2), age-related differences, interobserver agreement, and measurement reproducibility were assessed.RESULTS: In the right internal capsule genu (FA = 702/728; b = 1000/700 s/mm2) and the left anterior limb of the internal capsule (AIC; FA = 617/745; b = 1000/700 s/mm2), the FA values were significantly different between the 2 b-values (P = .02 and .05, respectively). Significant age-related differences in FA were observed in the genu of the corpus callosum and in the left AIC. Interrater measurements showed fair-to-moderate agreement for most anatomic structures. The lowest significant change for a single subject regarding any FA values between the 2 sessions was in the corpus callosum (4%), whereas the highest one was in the corticospinal tracts (27%). The Bland-Altman plot analysis showed that the 1000-s/mm2 b-value gave satisfactorily reproducible measurements equally good or better than the 700-s/mm2 b-value.CONCLUSION: The reproducibility of FA estimates using ROIs was satisfactory. Measurements with a b-value at 1000 s/mm2 showed superior reproducibility in most anatomic locations.