RT Journal Article SR Electronic T1 Stent Management of Coil Herniation in Embolization of Internal Carotid Aneurysms JF American Journal of Neuroradiology JO Am. J. Neuroradiol. FD American Society of Neuroradiology SP 1951 OP 1955 DO 10.3174/ajnr.A1268 VO 29 IS 10 A1 C.-B. Luo A1 F.-C. Chang A1 M.M.-H. Teng A1 W.-Y. Guo A1 C.-Y. Chang YR 2008 UL http://www.ajnr.org/content/29/10/1951.abstract AB BACKGROUND AND PURPOSE: Coil herniation into the parent artery after detachment is an uncommon complication of embolization of the intracranial aneurysm. We report our experience with stent reconstruction of the lumen and flow of the internal carotid artery (ICA) after coil herniation during embolization for intracranial ICA aneurysms and the possible mechanisms of coil herniation.MATERIALS AND METHODS: A series of 216 consecutive patients was treated by endovascular coil embolizations for intracranial aneurysms. Of these patients, there were 9 (4 men, 5 women; 32–68 years of age) complicating with coil herniation into the ICA and undergoing stent deployment to reconstruct the ICA lumen (n = 8) or both lumen and flow (n = 1). Wide-neck aneurysms were found in 8 and narrow-neck, in 1. Aneurysms were in the posterior communicating artery (n = 5) and the paraophthalmic (n = 3) and cavernous portions (n = 1) of the ICA. Self-expandable stents were deployed in the ICA in 6; balloon-mounted stents were selected in 3.RESULTS: The causes of coil herniation appeared to be coil instability after detachment (n = 6), excessive embolization (n = 1), microcatheter-related problems (n = 1), or being pushed by subsequent coil embolization (n = 1). Endovascular stent placement to reconstruct the lumen and/or flow of the ICA was technically successful in all 9 patients; 1 needed a second stent due to further coil migration. No significant procedure-related complications were found. Clinical follow-up was 8–35 months.CONCLUSION: Coil herniation occasionally occurs during endovascular embolization of ICA aneurysms because of coil instability after detachment, excessive embolization, microcatheter-related problems, or pushing by subsequent coil embolization. In this small series, stent placement was safe and effective in the reconstruction of the arterial lumen and/or restoration of flow past a herniated coil mass.