Summary of 11 patients receiving intracranial stents

Patient/Age(y)/SexLesion locationStenosis (%)Stent and Size (mm)*TechniqueTechnical Success
1/71/ML MCA70S660, 2.5 × 9WaitingYes
2/74/FR MCA70S660, 2.5 × 15Coaxial double—guiding catheterYes
3/76/FL distal VA60S660, 2.5 × 15Double wireYes
4/77/FL supraclinoid ICA60Flexmaster, 2.75 × 12WaitingYes
5/74/FR supraclinoid ICA70Flexmaster, 3.0 × 12WaitingYes
6/71/FL MCA60S660, 2.5 × 11WaitingYes
7/70/FL distal VA80Flexmaster, 3.0 × 16WaitingYes
8/53/ML MCA80Flexmaster, 2.5 × 16Coaxial double–guiding catheterYes
9/51/ML MCA70Flexmaster, 2.5 × 12Double wireYes
10/42/FL supraclinoid ICA75Flexmaster, 2.75 × 23Double wireYes
11/47/ML supraclinoid ICA100Flexmaster, 2.5 × 26Double wireYes
  • * Diameter × length. S660 made by Medtronic; Flexmaster, Jo Med GmbH.