TABLE 1:

Aneurysm detection at rotational DA and MIP, SSD, and volume-rendering 3D DA

Aneurysm Detection Score*Rotational DA (n = 30)MIP 3D DA (n = 30)SSD 3D DA (n = 30)Volume-Rendering 3D DA (n = 30)
+224 (80)25 (83)27 (90)29 (97)
+14 (13)3 (10)3 (10)1 (3)
02 (7)2 (7)0 (0)0 (0)
−10 (0)0 (0)0 (0)0 (0)
Mean score ± SD1.73 ± 0.581.77 ± 0.571.90 ± 0.311.97 ± 0.18
  • Note.—Data are number of aneurysms. Numbers in parentheses are percentages.

  • * +2 indicates sufficient visualization; +1, ambiguous visualization; 0, poor visualization; −1, misinterpretation.