Table 3:

Venous pressures before and after transverse sinus stent placement in 46 patients with IIH with and 6 without papilledemaa

Superior Sagittal Sinus Pressure Pre-stent (mm Hg)Superior Sagittal Sinus Pressure Post-stent (mm Hg)Gradient Pre-stent(mm Hg)Gradient Post-stent(mm Hg)
With papilledema3416200.7
(n = 46)(15–94)(11–33)(6–41)(0–14)
(n = 46)(n = 44)(n = 46)(n = 46)
Without papilledema2511120
(n = 6)(18–34)(7–14)(4–15)
(n = 6)(n = 6)(n = 6)(n = 4)
  • a Ranges indicated in parentheses.