Table 3:

Coefficient of variance of perfusion parameters in noise datasets generated in 6 trials at each noise level

Simulated Exposure (mAs)Coefficient of Variance (%)
CBFCBVMTT
1881.30.31.2
1772.10.71.9
1673.20.92.9
1274.11.94.6
447.14.56.7
  • Note:—Coefficient of variance is defined as SD/mean × 100.