Table 3:

nRCBV low- vs high-grade thresholds and ROC analysis results

Team/ Entry No.Software PlatformLeakage Correction UsedLG vs HG (P Value)ThresholdSNSPAUC
A1IB NeuroYes5.34E-061.6050.8610.8460.889
B1IB NeuroYes5.36E-061.6050.8610.8460.889
C1IB NeuroYes5.39E-061.6050.8610.8460.889
B2MatlabYes2.02E-061.3150.9720.7690.892
B3MatlabYes1.75E-061.3300.9720.7690.896
D1nordicICEYes3.30E-061.3050.9720.7690.895
D2nordicICEYes3.30E-061.3050.9720.7690.895
E1PGUI (LC)Yes7.32E-061.6150.8610.8460.892
E2PGUI (C)Yes1.14E-051.4000.8610.7690.871
E3PGUI (PM LC)Yes1.18E-051.4000.8890.7690.856
D3SlicerYes1.08E-061.4150.9440.7690.891
F1FIATYes2.50E-051.2350.9440.7690.853
G1McCBVYes1.26E-061.4250.9440.7690.891
A3IB NeuroNo1.55E-061.3300.9170.7690.895
B4IB NeuroNo1.56E-061.3300.9170.7690.895
E4PGUINo6.94E-061.4500.8610.7690.887
E5PGUINo5.67E-051.5850.8060.8460.872
E6PGUINo1.19E-051.3950.8610.7690.873
  • Note:—AUC indicates area under the curve; LG, low-grade; HG, high-grade.