SC GM, WM, and TSC accuracy of automatic and semiautomatic segmentations against the manual reference standard segmentationsa

ParameterGMWMTSC
AM (on 88% of acquired slices, nondiscarded from initial analysis)DSC0.86 ± 0.04 (0.87)0.90 ± 0.03 (0.91)0.95 ± 0.03 (0.95)
HD (mm)0.90 ± 0.44 (0.72)0.82 ± 0.22 (0.75)0.64 ± 0.27 (0.67)
SAM (on 12% of acquired slices, discarded from initial analysis)DSC0.83 ± 0.04 (0.84)0.96 ± 0.01 (0.96)
HD (mm)1.11 ± 0.55 (0.93)0.64 ± 0.15 (0.67)
AM (on nondiscarded samples) and SAM (on discarded slices), mixed (100% of acquired slices)DSC0.86 ± 0.04 (0.86)0.91 ± 0.04 (0.92)0.96 ± 0.03 (0.96)
HD (mm)0.91 ± 0.46 (0.81)0.80 ± 0.22 (0.75)0.60 ± 0.29 (0.55)
  • Note:—SAM indicates semiautomatic segmentation; TSC, total spinal cord; AM, automatic segmentations; DSC, Dice coefficient; HD, Hausdorff distances.

  • a All values are shown as mean ± SD (median).