Table 4:

Preprocedural hemodynamic qualitative inflow zone at the aneurysm neck

Response6-Month Follow-Up12-Month Follow-Up
Remnant (n = 19)Occlusion (n = 21)Remnant (n = 10)Occlusion (n = 30)
Proximal neck11368
Lateral side + distal neck7 + 112 + 64 + 015 + 7
χ2 analysis (P value)Significant difference (.004)No significant difference (.13)