Table 3:

Results of the fiber-tracking reconstructions obtained with the 4 adopted approaches for each patient

PatientMS-iFOD2SS-iFOD2SS-SD-STREAMSS-SD-STREAM-L
1 Anatomic Seed2 Anatomic Seeds
1AccurateDifferent nerve reconstructionAlgorithm failureAccurate, presence of FPAccurate
2AccurateAccurate, presence of PVEAccurateAccurate, presence of FP and PVEAccurate, presence of FP
3Partially accuratePartially accurate, presence of FPAlgorithm failurePartially accurate, presence of FP and PVEInconsistent reconstruction
4AccurateAccurate, presence of PVEAlgorithm failureInconsistent reconstructionAlgorithm failure
5AccurateAlgorithm failureAlgorithm failureInconsistent reconstructionAlgorithm failure
  • Note:—FP indicates false-positives.