Skip to main content

Advertisement

Log in

Radiation exposure to interventional radiologists during manual-injection digital subtraction angiography

  • Clinical Investigations
  • Published:
CardioVascular and Interventional Radiology Aims and scope Submit manuscript

Abstract

Purpose: We investigated the relationship between the amount of radiation exposure to the operator during tableside manual-injection angiographic procedures including digital subtraction angiography (DSA) and the operator’s position, as well as a simple means to decrease radiation exposure.

Methods: Measurement of radiation exposure was carried out with thermoluminescent dosimeters (TLDs) in nine abdominal angiographies. In the first study, radiation exposure during DSA or during fluoroscopy was measured using TLDs placed near the angiographic table. In the second study, radiation exposure to the interventional radiologist was measured during manual-injection DSA at a near and a far operator position.

Results: Radiation exposure to the operator received during manual-injection DSA accounted for more than 90% of the total procedural exposure. The exposure to the operator markedly decreased at the far position compared with that at the near position when performing DSA.

Conclusion: Manual-injection DSA is the largest contributor to radiation exposure received by the interventional radiologist, therefore, the use of a power injector is always recommended when performing DSA. When manual-injection DSA is necessary, radiologists should position themselves as far away from the patient as possible.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. NCRP (1990) Implementation of the principle of as low as reasonably achievable (ALARA) for medical and dental personnel. NCRP Report no. 107. Bethesda, Maryland

  2. Balter S, Sones M, Brancato R (1978) Radiation exposure to the operator performing cardiac angiography with C-arm systems. Circulation 58(5):925–932

    PubMed  CAS  Google Scholar 

  3. Riley RC, Birks JW, Palacios E, Templeton AW (1973) Exposure of radiologists during special procedures. Radiology 104:679–683

    Google Scholar 

  4. Chopp M, Portnoy HD, Schuvig R, Croissant P (1980) Clinical dosimetry during cerebral arteriography. Neuroardiology 20:74–81

    Google Scholar 

  5. Tryhus M, Mettler FA, Kalsey C (1987) The radiologist and angiographic procedures: Absorbed radiation dose. Invest Radiol 22:747–750

    Article  PubMed  CAS  Google Scholar 

  6. Cascade PN, Peterson LE, Wajszczuk WJ, Mantel J (1987) Radiation exposure to patients undergoing percutaneous transluminal coronary angioplasty. Am J Cardiol 59:996–997

    Article  PubMed  CAS  Google Scholar 

  7. Calkins H, Niklason L, Sousa J, El Attasi R, Langberg J, Morady F (1991) Radiation exposure during radiofrequency catheter ablation of accessory arterioventricular connections. Circulation 84:2376–2382

    PubMed  CAS  Google Scholar 

  8. Berthelsen B, Cederblad A (1991) Radiation doses to patients and personnel involved in embolization of intracerebral arteriovenous malformations. Acta Radiol 32:492–497

    Article  PubMed  CAS  Google Scholar 

  9. Wagner LK, Eifel PJ, Geise RA (1994) Potential biological effects following high X-ray dose interventional procedures. J Vasc Interv Radiol 5:71–84

    Article  PubMed  CAS  Google Scholar 

  10. Judkins MP (1984) Guidelines for radiation protection in the cardiac catheterization laboratory. Cathet Cardiovasc Diagn 10:87–92

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hayashi, N., Sakai, T., Kitagawa, M. et al. Radiation exposure to interventional radiologists during manual-injection digital subtraction angiography. Cardiovasc Intervent Radiol 21, 240–243 (1998). https://doi.org/10.1007/s002709900252

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002709900252

Key words

Navigation