Abstract
The aim of our present study was to evaluate the visualization of anatomical landmarks of the temporal bone using a low-dose 64-slice computed tomography (CT) technique. A total of 120 patients were evaluated, 60 patients (mean age 47.1 years; 36 male, 24 female) underwent examination with a 4-slice CT scanner: 180 mAs, 120 kV, 1 s rotation time, 2 × 0.5 mm collimation, 0.5 mm slice thickness. Another 60 consecutive patients (mean age 37.4 years; 43 male, 37 female) were examined using a 64-slice CT low-dose protocol: 140 mAs, 120 kV, 1 s rotation time, 12 × 0.6 mm collimation, 0.6 mm slice thickness. The visibility of 42 landmarks was scored by two blinded radiologists using a five-point quality rating scale. Mean equivalent dose was significantly lower for the 64-slice CT protocol (0.31 mSv ± 0.12 mSv) compared to the 4-slice CT protocol (0.61 mSv ± 0.08 mSv). Despite increased image noise, only 19% of the anatomical landmarks were delineated significantly better on the axial sections of the 4-slice CT and only 9.5% of the anatomical landmarks on the reformatted coronal images. The interobserver agreement did not differ significantly between the two modalities. Low-dose 64-slice CT technique facilitates temporal bone imaging with sufficient anatomical detail.
Similar content being viewed by others
References
Chakeres DW, Augustyn MA (2003) Temporal bone imaging. In: Som PM, Curtin HD (eds) Head and neck imaging, 4th edn. Mosby, St. Louis, MO, pp 1093–1108
Virapongse C, Rothman SLG, Kier EL, Sarwar M (1982) Computed tomographic anatomy of the temporal bone. Am J Roentgenol 139:739–749
Mayer TE, Brueckmann H, Siegert R, Witt A, Weerda H (1997) High resolution CT of the temporal bone in dysplasia of the auricle and external auditory canal. Am J Neuroradiol 18:53–65
Lemmerling MM, Stambuck HE, Mancuso AA, Antonelli PJ, Kubilis PS (1997) CT of the normal suspensory ligaments of the ossicles in the middle ear. Am J Neuroradiol 18:471–477
Westerhof JP, Rademaker J, Weber BP, Becker H (2001) Congenital malformations of the inner ear and vestibulocochlear nerve in children with sensorineural hearing loss: evaluation with CT and MRI. J Comput Assist Tomogr 25:719–726
Klingenbeck-Regn K, Schaller S, Flohr T et al (1993) Subsecond multi-slice computed tomography: basics and application. Eur J Radiol 31:110–124
Flohr T, Stiersdorfer K, Bruder H, Simon J, Staller S (2002) New technical developments in multislice CT. Part 1: Approaching isotropic resolution with sub-mm 16 slice scanning (in German). Fortschr Röntgenstr 174:839–845
Flohr T, Stiersdorfer K, Raupach R, Ulzheimer S, Bruder H (2004) Performance evaluation of a 64-slice CT system with z-flying focal spot (in German). Fortschr Röntgenstr 176:1803–1810
Cohnen M, Fischer H, Hamacher J, Lins E, Kotter R, Modder U (2000) CT of the head by use of reduced current and kilovoltage: relation between image quality and dose reduction. Am J Neuroradiol 21:1654–1660
Coppenrath E, Meindl T, Herzog P, Khalil R, Mueller-Lisse U, Krenn L, Reiser M, Mueller-Lisse UG (2006) Dose reduction in multidetector CT of the urinary tract. Studies in a phantom model. Eur Radiol 16:1982–1989
Hohl C, Muhlenbruch G, Wildberger JE, Leidecker C, Suss C, Schmidt T, Gunther RW, Mahnken AH (2006) Estimation of radiation exposure in low-dose multislice computed tomography of the heart and comparison with a calculation program. Eur Radiol 16(8):1841–1846
Bongartz G, Golding SJ, Jurik AG, van Merten EP (1999) European guidelines on quality criteria for computed tomography. Report EUR 16262EN. Office for Official Publications of the European Communities, Luxembourg
Hamberg LM, Rhea JT, Hunter GJ, Thrall JH (2003) Multi-detector row CT: radiation dose characteristics. Radiology 226:762–772
Marmolya G, Wiesen EJ, Yagan R, Haria CD, Shah AC (1991) Paranasal sinuses: low-dose CT. Radiology 181:689–691
Sohaib SA, Peppercorn PD, Horrocks JA, Keene MH, Kenyon GS, Reznek RH (2001) The effect of decreasing mAs on image quality and patient dose in sinus CT. Br J Radiol 74:157–161
Hein E, Rogalla P, Klingebiel R, Hamm B (2002) Low-dose CT of the paranasal sinuses with eye lense protection: effect on image quality and radiation dose. Eur Radiol 12:1693–1696
Tack D, Widelec J, Maertelaer V, Baily JM, Delcous C, Gevenois PA (2003) Comparison between low-dose and standard-dose multidetector CT in patients with suspected chronic sinusitis. Am J Roentgenol 181:939–944
Takahashi M, Maguire WM, Ashtari M, Khan A, Papp Z, Alberico R, Campbell W, Eacobacci T, Hernan PG (1998) Low-dose spiral computed tomography of the thorax: comparison with the standard dose technique. Invest Radiol 33:68–73
Kalra MK, Prasad S, Saini S, Blake MA, Varghese J, Halpern EF, Thrall JW, Rhea JT (2002) Clinical comparison of standard dose and 50% reduced-dose abdominal CT: effect on image quality. Am J Roentgenol 179:1101–1106
Kamel IR, Hernandez RJ, Martin JE, Schlesinger AE, Niklason LT, Guire KE (1994) Radiation dose reduction in CT of the pediatric pelvis. Radiology 190:683–687
Mullins ME, Lev MH, Bove P (2004) Comparison of image quality between conventional and low-dose nonenhanced head CT. Am J Neuroradiol 25:533–538
Lorenzen M, Wedegärtner U, Weber C, Lockermann U, Adam G, Lorenzen J (2005) Dose optimization for multislice computed tomography protocols of the midface (in German). Fortschr Röntgenstr 177:265–271
Lee CP, Black ML, Lamb RB, Arnold JP, Seibert JA, Chole RA, Bacon GV (1989) CT evaluation of the temporal bone ossicles by using oblique reformations. Am J Neuroradiol 10:431–433
Husstedt HW, Prokop M, Dietrich B, Becker H (2001) Low-dose high-resolution CT of the petrous bone. J Neuroradiol 27:87–92
Krombach GA, van den Boom M, Di Martino E (2005) Computed tomography of the inner ear: size of anatomical structures in the normal temporal bone and in the temporal bone of patients with Maniere’s disease. Eur Radiol 15:1505–1513
Jäger L, Bonell H, Liebl M, Srivastav S, Arbusov V, Hempel M, Reiser M (2005) CT of the normal temporal bone: comparison of multi- and single-detector row CT. Radiology 235:133–141
Gupta R, Bartling SH, Basu SK, Ross WR, Becker H, Pfoh A, Brady T, Curtin HD (2004) Experimental flat-panel high resolution volume CT of the temporal bone. Am J Neuroradiol 25:1417–1424
Jäger L, Reiser M (2001) CT and MR imaging of the normal and pathologic conditions of the facial nerve. Eur J Radiol 40:133–146
Helms J (1981) Variations of the course of the facial nerve in the middle ear and mastoid. In: Samii M, Janetta PJ (eds) The cranial nerves. Springer, Berlin, pp 391–393
Dimopoulos PA, Muren C, Smedby O, Wadin K (1996) Anatomical variations of the tympanic and mastoid portions of the facial nerve canal: a radioanatomical investigation. Acta Radiol Suppl 403:49–59
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Lutz, J., Jäger, V., Hempel, M.J. et al. Delineation of temporal bone anatomy: feasibility of low-dose 64-row CT in regard to image quality. Eur Radiol 17, 2638–2645 (2007). https://doi.org/10.1007/s00330-007-0578-1
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00330-007-0578-1