Skip to main content
Log in

Two-dimensional thick-slice MR digital subtraction angiography for assessment of cerebrovascular occlusive diseases

  • Neuroradiology Original article
  • Published:
European Radiology Aims and scope Submit manuscript

Abstract.

Although spatial resolution of current MR angiography is excellent, temporal resolution has remained unsatisfactory. We evaluated clinical applicability of 2D thick-slice, contrast-enhanced subtraction MR angiography (2D-MR digital subtraction angiography) with sub-second temporal resolution in cerebrovascular occlusive diseases. Twenty-five patients with cerebrovascular occlusive diseases (8 moyamoya diseases, 10 proximal internal carotid occlusions, and 2 sinus thromboses ) were studied with a 1.5-T MR unit. The MR digital subtraction angiography (MRDSA) was performed per 0.97 s continuously just after a bolus injection of 15 ml of gadolinium chelates up to 40 s in sagittal (covering hemisphere) or coronal planes. Subtraction images were generated at a workstation. We evaluated imaging quality and hemodynamic information of MRDSA in comparison with those of routine MR imaging, non-contrast MR angiography, and X-ray intra-arterial DSA. Major cerebral arteries, all of the venous sinuses, and most tributaries were clearly visualized with 2D MRDSA. Also, pure arterial phases were obtained in all cases. The MRDSA technique demonstrated prolonged circulation in sinus thromboses, distal patent lumen of proximal occlusion, and some collateral circulation. Such hemodynamic information was comparable to that of intra-arterial DSA. Two-dimensional thick-slice MRDSA with high temporal resolution has a unique ability to demonstrate cerebral hemodynamics equivalent to that of intra-arterial DSA and may play an important role for evaluation of cerebrovascular occlusive diseases.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 16 November 1999; Revised: 27 June 2000; Accepted: 29 June 2000

Rights and permissions

Reprints and permissions

About this article

Cite this article

Aoki, S., Yoshikawa, T., Hori, M. et al. Two-dimensional thick-slice MR digital subtraction angiography for assessment of cerebrovascular occlusive diseases. Eur Radiol 10, 1858–1864 (2000). https://doi.org/10.1007/s003300000584

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s003300000584

Navigation