Skip to main content
Log in

Utility of catheter-assisted Guglielmi detachable coiling in the treatment of wide-necked aneurysms

  • Clinical Article
  • Published:
Acta Neurochirurgica Aims and scope Submit manuscript

Summary

Background. Catheter-assisted Guglielmi detachable coiling (CAGDC) is a technical option that was developed to allow the endovascular treatment of wide-necked aneurysms. We report upon our experiences of the CAGDC in treating aneurysms with an assessment of its efficacy and safety.

Methods. The effect of CAGDC of wide-necked aneurysms was retrospectively evaluated in 10 patients (5 females, 5 males, mean age 56, range 40–76 yrs) who underwent the procedure.

Findings. All the aneurysms were successfully embolized with CAGDC. Eight patients presented with SAH from an acutely ruptured aneurysm. Six patients were available for an angiographic follow up (mean: 10.3 months, range: 6–12 months). At the angiographic follow-up, all the aneurysms were stable and occluded (3 aneurysms with complete and 3 with near complete packing of the sac and neck). Complications directly related to the procedure were encountered in two patients (one coil migration, one thrombo-embolism). Three patients died as a result of complication of subarachnoid hemorrhage.

Conclusion. CAGDC is a viable option for the treatment of wide neck aneurysms prior to balloon (or stent) assisted coil embolization.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • MB Horowitz E Levy A Kassam PD Purdy (2002) ArticleTitleEndovascular therapy for intracranial aneurysms: a historical and present status review Surg Neurol 57 147–158 Occurrence Handle12009536 Occurrence Handle10.1016/S0090-3019(01)00701-7

    Article  PubMed  Google Scholar 

  • F Vinuela G Duckwiler M Mawad (1997) ArticleTitleGuglielmi detachable coil embolization of acute intracranial aneurysm: perioperative anatomical and clinical outcome in 403 patients J Neurosurg 86 475–482 Occurrence Handle9046305 Occurrence Handle1:STN:280:DyaK2s7pvVamsw%3D%3D

    PubMed  CAS  Google Scholar 

  • A Zubillaga G Guglielmi F Vinuela G Duckwiler (1994) ArticleTitleEndovascular occlusion of intracranial aneurysms with electrically detachable coils: correlation of aneurysm neck size and treatment results AJNR 15 815–820

    Google Scholar 

  • JK Hope JV Byrne AJ Molyneus (1999) ArticleTitleFactors influencing successful angiographic occlusion of aneurysms treated by coil embolization AJNR 20 391–399 Occurrence Handle10219403 Occurrence Handle1:STN:280:DyaK1M3js1WnsQ%3D%3D

    PubMed  CAS  Google Scholar 

  • J Moret C Cognard A Weill et al. (1997) ArticleTitleThe “remodelling technique” in the treatment of wide neck intracranial aneurysms Intervent Neuroradiol 3 21–35

    Google Scholar 

  • DI Levy A Ku (1997) ArticleTitleBalloon-assisted coil placement in wide-necked aneurysms J Neurosurg 86 724–727 Occurrence Handle9120640 Occurrence Handle1:STN:280:DyaK2s3jsVWmsw%3D%3D Occurrence Handle10.3171/jns.1997.86.4.0724

    Article  PubMed  CAS  Google Scholar 

  • WP Sanders TH Burke BA Mehta (1998) ArticleTitleEmbolization of intracranial aneurysms with guglielmi detachable coils augmented by microballoons AJNR 19 917–920 Occurrence Handle9613512 Occurrence Handle1:STN:280:DyaK1c3ntlGlug%3D%3D

    PubMed  CAS  Google Scholar 

  • MA Lefkowitz YP Gobin Y Akiba et al. (1999) ArticleTitleBalloon-assisted Guglielmi detachable coiling of wide-necked aneurysms: part II – clinical results Neurosurgery 45 531–538 Occurrence Handle10493375 Occurrence Handle1:STN:280:DyaK1MvitFWiug%3D%3D Occurrence Handle10.1097/00006123-199909000-00024

    Article  PubMed  CAS  Google Scholar 

  • JP Cottier A Pasco S Gallas J Grabrillargues C Cognard J Drouineau L Brunereau D Herbreteau (2001) ArticleTitleUtility of balloon-assisted Guglielmi detachable coiling in the treatment of 49 cerebral aneurysms: a retrospective, multicenter study AJNR 22 345–351 Occurrence Handle11156781 Occurrence Handle1:STN:280:DC%2BD3M7ntFCnuw%3D%3D

    PubMed  CAS  Google Scholar 

  • PK Nelson DI Levy (2001) ArticleTitleBalloon-assisted coil embolization of wide-necked aneurysms of the internal carotid artery: medium-term angiographic and clinical follow-up in 22 patients AJNR 22 19–26 Occurrence Handle11158882 Occurrence Handle1:STN:280:DC%2BD3M7nslygsw%3D%3D

    PubMed  CAS  Google Scholar 

  • S Baldi C Mounayer M Piotin L Spelle J Moret (2003) ArticleTitleBalloon-assisted coil placement in wide-neck bifurcation aneurysm by use of a new, compliant balloon microcatheter AJNR 24 1222–1225 Occurrence Handle12812958

    PubMed  Google Scholar 

  • B Lubicz X Leclerc JY Gauvrit JP Lejeune JP Pruvo (2004) ArticleTitleHyperform remodeling-balloon for endovascular treatment of wide-neck intracranial aneurysms AJNR 25 1381–1383 Occurrence Handle15466337

    PubMed  Google Scholar 

  • CC Phatouros VV Halbach AM Malek CF Dowd RT Higashida (1999) ArticleTitleSimultaneous subarchnoid hemorrhage and carotid cavernous fistula after rupture of a paraclinoid aneurysm during balloon-assisted coil embolization AJNR 20 1100–1102 Occurrence Handle10445450 Occurrence Handle1:STN:280:DyaK1Mznt1KhsA%3D%3D

    PubMed  CAS  Google Scholar 

  • HJ Cloft GJ Joseph FC Tong JH Goldstein JE Dion (2000) ArticleTitleUse of three-dimensional Guglielmi detachable coils in the treatment of wide-necked cerebral aneurysms AJNR 21 1312–1314 Occurrence Handle10954285 Occurrence Handle1:STN:280:DC%2BD3M%2FotlOmsg%3D%3D

    PubMed  CAS  Google Scholar 

  • JN Vallee L Pierot A Bonafe F Turjman P Flandroy J Berge G Rodesch S Bracard (2004) ArticleTitleEndovascular treatment of intracranial wide-necked aneurysms using three-dimensional coils: predictors of immediate anatomic and clinical results AJNR 25 298–306 Occurrence Handle14970036

    PubMed  Google Scholar 

  • RT Higashida W Smith D Gress R Urwin CF Dowd PA Balousek VV Halbach (1997) ArticleTitleIntravascular stent and endovascular coil placement for a ruptured fusiform aneurysm of the basilar artery: case report and review of the literature J Neurosurg 87 944–949 Occurrence Handle9384409 Occurrence Handle1:STN:280:DyaK1c%2FksVSltw%3D%3D

    PubMed  CAS  Google Scholar 

  • G Lanzino AK Wakhloo RD Fessler ML Hartney LR Guterman LN Hopkins (1999) ArticleTitleEfficacy and current limitations of intravascular stents for intracranial internal carotid, vertebral, and basilar artery aneurysms J Neurosurg 91 538–546 Occurrence Handle10507372 Occurrence Handle1:STN:280:DyaK1MvjsFajtA%3D%3D Occurrence Handle10.3171/jns.1999.91.4.0538

    Article  PubMed  CAS  Google Scholar 

  • G Wilms FV Calenbergh L Stockx P Demaerel JV Loon J Goffin (2000) ArticleTitleEndovascular treatment of a ruptured paraclinoid aneurysm of the carotid siphon achieved using endovascular stent and endosaccular coil placement AJNR 21 753–756 Occurrence Handle10782790 Occurrence Handle1:STN:280:DC%2BD3c3kt1yrtg%3D%3D

    PubMed  CAS  Google Scholar 

  • MI Mohammed JS Sandhu AK Wakhloo (2002) ArticleTitleStent-assisted coil placement in a wide-necked persistent trigeminal artery aneurysm with jailing of the trigeminal artery: a case report AJNR 23 437–441 Occurrence Handle11901014

    PubMed  Google Scholar 

  • I Wanke A Doerfler B Schoch D Stolke M Forsting (2003) ArticleTitleTreatment of wide-necked intracranial aneurysms with a self-expanding stent system: initial clinical experience AJNR 24 1192–1199 Occurrence Handle12812954

    PubMed  Google Scholar 

  • K Alfke T Straube L Dorner M Mehdorn O Jansen (2004) ArticleTitleTreatment of intracranial broad-neck aneurysms with a new self-expanding stent and coil embolization AJNR 25 509–512

    Google Scholar 

  • B Jennet M Bond (1975) ArticleTitleAssessment of outcome after severe brain damage. A practical scale Lancet 305 480–484 Occurrence Handle10.1016/S0140-6736(75)92830-5

    Article  Google Scholar 

  • LP Broadbent CJ Moran DT Cross SuffixIII CP Derdeyn (2003) ArticleTitleMangement of neuroform stent dislodgement and misplacement AJNR 24 1819–1822 Occurrence Handle14561609

    PubMed  Google Scholar 

  • H Wada M Piotin H Boissonnet L Spelle C Mounayer J Moret (2004) ArticleTitleCarotid rupture during stent-assisted aneurysm treatment AJNR 25 827–829 Occurrence Handle15140729

    PubMed  Google Scholar 

  • D Fiorella FC Albuquerque VR Deshmukh CG McDougall (2004) ArticleTitleIn-stent stenosis as a delayed complication of neuroform stent-supported coil embolization of an incidental carotid terminus aneurysm AJNR 25 1764–1767 Occurrence Handle15569743

    PubMed  Google Scholar 

  • BW Baxter D Rosso SP Lownie (1998) ArticleTitleDouble microcatheter technique for detachable coil treatment of large, wide-necked intracranial aneurysms AJNR 19 1176–1178 Occurrence Handle9672035 Occurrence Handle1:STN:280:DyaK1czjsFOmtA%3D%3D

    PubMed  CAS  Google Scholar 

  • OK Kwon SH Kim BJ Kwon HS Kang JH Kim CW Oh MH Han (2005) ArticleTitleEndovascular treatment of wide-necked aneurysms by using two microcatheters: techniques and outcomes in 25 patients AJNR 26 894–900 Occurrence Handle15814940

    PubMed  Google Scholar 

  • T Nakahara M Kutsuna M Yamanaka K Sakoda (1999) ArticleTitleCoil embolization of a large, wide necked aneurysm using a double coil-delivered microcatheter technique in combination with a balloon-assisted technique Neurol Res 21 IssueID3 324–326 Occurrence Handle10319344 Occurrence Handle1:STN:280:DyaK1M3lt12jsA%3D%3D

    PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ihn, Y., Kim, DI., Kim, BS. et al. Utility of catheter-assisted Guglielmi detachable coiling in the treatment of wide-necked aneurysms. Acta Neurochir (Wien) 148, 1045–1052 (2006). https://doi.org/10.1007/s00701-006-0881-7

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00701-006-0881-7

Navigation