Low-dose 3D time-resolved magnetic resonance angiography (MRA) of the supraaortic arteries: correlation with high spatial resolution 3D contrast-enhanced MRA

J Magn Reson Imaging. 2011 Jan;33(1):71-6. doi: 10.1002/jmri.22396.

Abstract

Purpose: To evaluate the feasibility of low-dose, 3D time-resolved contrast-enhanced magnetic resonance angiography (TR-CEMRA) in the assessment of the supraaortic vessel, and to compare the results with high-resolution contrast-enhanced MRA (HR-CEMRA).

Materials and methods: This was an Institutional Review Board-approved retrospective study. Forty-five consecutive patients underwent contrast-enhanced 3D TR-CEMRA and 3D HR-CEMRA for evaluation of neurovascular disease at 3.0 T. Gadobutrol was administered at a constant dose of 1 mL for TR-CEMRA (independent of patient weight), and 0.1 mmol/kg for HR-CEMRA. Two readers evaluated image quality using a four-point scale (from 0 = excellent to 3 = nondiagnostic), and subsequently graded each stenosis into clinically relevant categories: normal (0%), mild stenosis (<50%), moderate to severe (>50%), and occlusion.

Results: The overall image quality for low-dose TR-CEMRA was in the diagnostic range (median 0, range 0-3). On the grading of stenosis, TR-CEMRA using the TWIST sequence correlated with HR-CEMRA (r = 0.668, P < 0.001). In terms of the comparison of TR-CEMRA with HR-CEMRA, of the 675 supraaortic arterial segments evaluated for stenosis or occlusion, agreement occurred in 611 of 675 (90.5%), overestimation in 41 of 675 (6.1%), and underestimation 23 of 675 (3.4%).

Conclusion: TR-CEMRA achieved by administration of a small contrast dose (1 cc) yields rapid and important functional and anatomical information in the evaluation of supraaortic arteries. Due to limited spatial resolution, TR-CEMRA at the current parameters has a tendency to overestimate the stenosis of smaller intracranial arteries compared to HR-CEMRA.

Publication types

  • Comparative Study
  • Evaluation Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Aorta / pathology*
  • Aortic Valve Stenosis / complications
  • Aortic Valve Stenosis / pathology*
  • Cerebrovascular Disorders / etiology
  • Cerebrovascular Disorders / pathology*
  • Contrast Media / administration & dosage
  • Dose-Response Relationship, Drug
  • Female
  • Humans
  • Image Enhancement / methods
  • Image Interpretation, Computer-Assisted / methods*
  • Imaging, Three-Dimensional / methods
  • Magnetic Resonance Angiography / methods*
  • Male
  • Middle Aged
  • Organometallic Compounds / administration & dosage*
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Statistics as Topic
  • Young Adult

Substances

  • Contrast Media
  • Organometallic Compounds
  • gadobutrol