Evaluation framework for carotid bifurcation lumen segmentation and stenosis grading

Med Image Anal. 2011 Aug;15(4):477-88. doi: 10.1016/j.media.2011.02.004. Epub 2011 Feb 17.

Abstract

This paper describes an evaluation framework that allows a standardized and objective quantitative comparison of carotid artery lumen segmentation and stenosis grading algorithms. We describe the data repository comprising 56 multi-center, multi-vendor CTA datasets, their acquisition, the creation of the reference standard and the evaluation measures. This framework has been introduced at the MICCAI 2009 workshop 3D Segmentation in the Clinic: A Grand Challenge III, and we compare the results of eight teams that participated. These results show that automated segmentation of the vessel lumen is possible with a precision that is comparable to manual annotation. The framework is open for new submissions through the website http://cls2009.bigr.nl.

Publication types

  • Evaluation Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Algorithms
  • Angiography / methods*
  • Carotid Arteries / diagnostic imaging*
  • Carotid Stenosis / diagnostic imaging*
  • Humans
  • Imaging, Three-Dimensional / methods*
  • Pattern Recognition, Automated / methods*
  • Radiographic Image Enhancement / methods
  • Radiographic Image Interpretation, Computer-Assisted / methods*
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Tomography, X-Ray Computed / methods*