Multicenter, intra-individual comparison of single dose gadobenate dimeglumine and double dose gadopentetate dimeglumine for MR angiography of the peripheral arteries (the Peripheral VALUE Study)

J Magn Reson Imaging. 2013 Oct;38(4):926-37. doi: 10.1002/jmri.24040. Epub 2013 Jan 31.

Abstract

Purpose: To prospectively compare single dose gadobenate dimeglumine with double dose gadopentetate dimeglumine for CE-MRA in patients with peripheral arterial occlusive disease (PAOD) using an intra-individual crossover study design in which all patients received both contrast agents in otherwise identical CE-MRA examinations.

Materials and methods: Institutional review board and regulatory approval were granted and all patients provided written informed consent. Sixty-eight patients (53M/15F; 62.4 ± 15.7 years) with mild-to-severe PAOD were enrolled for randomized 3-station CE-MRA with 0.1 mmol/kg gadobenate dimeglumine and 0.2 mmol/kg gadopentetate dimeglumine. Three blinded readers assessed images for vessel anatomical delineation, disease detection/exclusion, and global preference. Diagnostic performance for detection of ≥51% stenosis was determined for 53 patients who underwent DSA. Noninferiority was assessed using the Wilcoxon Signed Rank, McNemar, and Wald tests. Quantitative enhancement was compared.

Results: No differences (P ≥ 0.25) were noted for any qualitative parameter at any station. Equivalence was reported in at least 62/64 patients (93.8% 3-reader agreement) for diagnostic preference. Superiority for gadobenate dimeglumine was reported by all readers for diagnostic performance (sensitivity: 80.4-88.0% versus 75.2-85.8%; specificity: 89.8-96.0% versus 88.7-94.8%; accuracy: 87.4-91.7% versus 84.9-90.6%; PPV: 84.0-92.8% versus 82.3-90.8%; NPV: 88.5-92.4% versus 85.7-91.1%). Quantitative enhancement was similar in the pelvis but significantly (P < 0.05) greater with gadobenate dimeglumine in the thigh for two readers.

Conclusion: Image quality and diagnostic performance on peripheral CE-MRA with 0.1 mmol/kg gadobenate dimeglumine is at least equivalent to that with 0.2 mmol/kg gadopentetate dimeglumine.

Keywords: comparative studies; contrast-enhanced MR angiography; gadolinium contrast agents; peripheral arteries.

Publication types

  • Clinical Trial, Phase III
  • Comparative Study
  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Arteries / pathology*
  • Contrast Media / chemistry
  • Cross-Over Studies
  • Female
  • Gadolinium DTPA / administration & dosage*
  • Humans
  • Image Processing, Computer-Assisted
  • Magnetic Resonance Angiography*
  • Male
  • Meglumine / administration & dosage
  • Meglumine / analogs & derivatives*
  • Middle Aged
  • Observer Variation
  • Organometallic Compounds / administration & dosage*
  • Predictive Value of Tests
  • Prospective Studies
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Young Adult

Substances

  • Contrast Media
  • Organometallic Compounds
  • gadobenic acid
  • Meglumine
  • Gadolinium DTPA