Effect of Template Reporting of Brain MRIs for Multiple Sclerosis on Report Thoroughness and Neurologist-Rated Quality: Results of a Prospective Quality Improvement Project

J Am Coll Radiol. 2017 Mar;14(3):371-379.e1. doi: 10.1016/j.jacr.2016.09.037. Epub 2016 Dec 5.

Abstract

Purpose: To assess the impact of structured reporting templates on the objective and subjective quality of radiology reports for brain MRIs in patients with multiple sclerosis (MS).

Methods: A HIPAA-compliant prospective quality improvement initiative was undertaken to develop and implement a 12-item structured reporting template for brain MRI examinations in patients with known or suspected MS based on published guidelines. Reports created 1 year before implementing the template served as the baseline. A random sample of 10 template and 10 non-template reports was sent to five neurologists outside the study institution with MS expertise, who reviewed the reports for comprehensiveness and quality. The number of MS-relevant elements in template and non-template reports were compared with unpaired t tests. Proportions were compared with χ2 and Fisher exact tests.

Results: There were 63 reports in the pre-template period and 93 reports in the post-template period. Use of the template increased over time in the post-template period (P = .04). All 12 MS-relevant findings were addressed more often and with less variability in template reports: (11.1 ± 0.7 findings versus 5.8 ± 2.2 findings in non-template reports, P < .001). Neurologists were more likely to give the template reports the highest positive rating (56% [107/190] versus 28% [56/199], P < .001) and less likely to give the template reports a lower rating (7% [13/190] versus 15% [29/199], P = .01) compared with the non-template reports.

Conclusion: Template reporting of brain MRI examinations increases the rate at which MS-relevant findings are included in the report. Standardized reports are preferred by neurologists with MS expertise.

Keywords: Radiology templates; multiple sclerosis; quality improvement; radiology report; template reporting.

MeSH terms

  • Adult
  • Aged
  • Documentation / standards*
  • Female
  • Humans
  • Magnetic Resonance Imaging / standards*
  • Male
  • Middle Aged
  • Multiple Sclerosis / diagnostic imaging*
  • Neuroimaging / standards*
  • Neurologists
  • Prospective Studies
  • Quality Improvement*
  • United States