3D phase contrast MRI: Partial volume correction for robust blood flow quantification in small intracranial vessels

Magn Reson Med. 2018 Jan;79(1):129-140. doi: 10.1002/mrm.26637. Epub 2017 Feb 28.

Abstract

Purpose: Recent advances in 3D-PCMRI (phase contrast MRI) sequences allow for measuring the complex hemodynamics in cerebral arteries. However, the small size of these vessels vs spatial resolution can lead to non-negligible partial volume artifacts, which must be taken into account when computing blood flow rates. For this purpose, we combined the velocity information provided by 3D-PCMRI with vessel geometry measured with 3DTOF (time of flight MRI) or 3DRA (3D rotational angiography) to correct the partial volume effects in flow rate assessments.

Methods: The proposed methodology was first tested in vitro on cylindrical and patient specific vessels subject to fully controlled pulsatile flows. Both 2D- and 3D-PCMRI measurements using various spatial resolutions ranging from 20 to 1.3 voxels per vessel diameter were analyzed and compared with flowmeter baseline. Second, 3DTOF, 2D- and 3D-PCMRI measurements were performed in vivo on 35 patients harboring internal carotid artery (ICA) aneurysms indicated for endovascular treatments requiring 3DRA imaging.

Results: The in vitro 2D- and 3D-PCMRI mean flow rates assessed with partial volume correction showed very low sensitivity to the acquisition resolution above ≈2 voxels per vessel diameter while uncorrected flow rates deviated critically when decreasing the spatial resolution. 3D-PCMRI flow rates measured in vivo in ICA agreed very well with 2D-PCMRI data and a good flow conservation was observed at the C7 bifurcation. Globally, partial volume correction led to 10-15% lower flow rates than uncorrected values as those reported in most of the published studies on intracranial flows.

Conclusion: Partial volume correction may improve the accuracy of PCMRI flow rate measurements especially in small vessels such as intracranial arteries. Magn Reson Med 79:129-140, 2018. © 2017 International Society for Magnetic Resonance in Medicine.

Keywords: PCMRI; Partial volume correction; blood flow; intracranial arteries.

MeSH terms

  • Adult
  • Artifacts
  • Blood Flow Velocity
  • Carotid Artery, Internal / diagnostic imaging*
  • Cerebral Arteries / diagnostic imaging
  • Cerebrovascular Circulation
  • Female
  • Hemodynamics
  • Humans
  • Imaging, Three-Dimensional / methods*
  • Intracranial Aneurysm / pathology
  • Magnetic Resonance Imaging / methods*
  • Male
  • Middle Aged
  • Models, Statistical
  • Pulsatile Flow