Should we be moving to a national standardized non-gadolinium MR imaging protocol for the surveillance of vestibular schwannomas?

Br J Radiol. 2019 Apr;92(1096):20180833. doi: 10.1259/bjr.20180833. Epub 2019 Jan 23.

Abstract

Objectives:: To examine whether the model of Getting It Right First Time (GIRFT) could be relevant to the surveillance of non-operated vestibular schwannomas (vs) by testing the following hypotheses: (1) in the UK there is a great variation in the imaging protocol for the follow-up of vs; (2) high-resolution, T 2 weighted MRI (HRT 2W-MRI) has an equivalent accuracy to gadolinium-enhanced T 1 weighted MRI (Gd-MRI) in the assessment of vs size and; (3) imaging with HRT 2W-MRI rather than Gd-MRI could offer financial savings.

Methods:: Two neuroradiologists independently performed measurements of 50 vs imaged with HRT 2W-MRI and Gd-MRI. Differences in mean tumour measurements between HRT 2W-MRI and Gd-MRI were determined, as were intra- and interobserver concordance. Level of agreement was measured using Bland-Altman plots. Consultant neuroradiologists within 30 adult neurosurgical units in the UK were contacted via email and asked to provide the MRI protocol used for the surveillance of non-operated vs in their institution. The financial difference between scanning with HRT 2W-MRI and Gd-MRI was determined within Leeds Teaching Hospitals NHS Trust.

Results:: There was no statistically significant difference in the mean diameter of vs size, measured on HRT 2W-MRI and Gd-MRI (p = 0.28 & p = 0.74 for observers 1 and 2 respectively). Inter- and intraobserver concordance were excellent (Interclass correlation coefficient = 0.99, Interclass correlation coefficient ≥ 0.98 respectively). Differences between the two sequences were within limits of agreement. 26 of 30 UK neuroscience centres (87 % response rate) provided imaging protocols. 16 of the 26 (62%) centres use Gd-MRI for the surveillance of vs. HRT 2-MRI is £36.91 cheaper per patient than Gd-MRI.

Conclusion:: Variation exits across UK centres in the imaging surveillance of non-operated vs. HRT 2W-MRI and Gd-MRI have equivalent accuracy when measuring vs. Imaging with HRT 2W-MRI rather than Gd-MRI offers potential financial savings.

Advances in knowledge:: This study highlights the potential health and economic benefits of a national standardized imaging protocol for the surveillance of non-operated vs.

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Clinical Protocols
  • Female
  • Humans
  • Magnetic Resonance Imaging / methods*
  • Male
  • Middle Aged
  • Neuroma, Acoustic / diagnostic imaging*
  • Prospective Studies
  • Reproducibility of Results