Patency of branches after coverage with multiple telescoping flow-diverter devices: an in vivo study in rabbits

D Dai, YH Ding, R Kadirvel, AE Rad… - American journal …, 2012 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: The safety of placing multiple overlapped endoluminal
flow diverters remains unclear because small eloquent branch arteries theoretically could …

Effects of metal coverage rate of flow diversion device on neointimal growth at side branch ostium and stented artery: an animal experiment in rabbit abdominal aorta

B Hong, K Wang, Q Huang, Y Xu, X Fang, Z Li, J Liu - Neuroradiology, 2012 - Springer
Introduction To access the effect of actual metal coverage rate (MCR) on neointimal growth
at covered side branch ostium and stented artery after implantation of a flow diversion …

Flow diverters can occlude aneurysms and preserve arterial branches: a new experimental model

TE Darsaut, F Bing, I Salazkin… - American journal of …, 2012 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: FDs are new intracranial stents designed to occlude
aneurysms while preserving flow to jailed arterial branches. We tested this fundamental …

The success of flow diversion in large and giant sidewall aneurysms may depend on the size of the defect in the parent artery

JC Gentric, TE Darsaut, A Makoyeva… - American Journal …, 2014 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Flow diverters are designed to occlude aneurysms while
preserving flow to jailed arterial branches. We postulated that treatment success depended …

Experimental testing of a new generation of flow diverters in sidewall aneurysms in rabbits

YH Ding, T Tieu, DF Kallmes - American Journal of …, 2015 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: The development of new generation flow-diverting
devices will improve the result of flow diversion in challenging aneurysms. The Flow …

[HTML][HTML] A new flow-diverter (the FloWise): in-vivo evaluation in an elastase-induced rabbit aneurysm model

BM Kim, DJ Kim, DI Kim - Korean journal of radiology, 2016 - ncbi.nlm.nih.gov
Objective We aimed to evaluate the efficacy and safety of a newly developed, partially
retrievable flow-diverter (the FloWise) in an elastase-induced rabbit aneurysm model …

Building multidevice pipeline constructs of favorable metal coverage: a practical guide

M Shapiro, E Raz, T Becske… - American Journal of …, 2014 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: The advent of low-porosity endoluminal devices, also
known as flow diverters, exemplified by the Pipeline in the United States, produced the …

Flow diverters failing to occlude experimental bifurcation or curved sidewall aneurysms: an in vivo study in canines

TE Darsaut, F Bing, I Salazkin, G Gevry… - Journal of …, 2012 - thejns.org
Object Flow diverters (FDs) are increasingly used to treat complex intracranial aneurysms,
but preclinical studies that could guide clinical applications are lacking. The authors …

Evaluation of occurring complications after flow diverter treatment of elastase-induced aneurysm in rabbits using micro-CT and MRI at 9.4 T

A Simgen, D Ley, C Roth, GFM Cattaneo… - Neuroradiology, 2016 - Springer
Introduction Flow diverters are increasingly being used to treat intracranial aneurysms. This
study evaluates occurring complications of flow-diverting devices in the treatment of …

[HTML][HTML] Patency of posterior circulation branches covered by flow diverter device: a hemodynamic study

X Wu, Z Tian, J Liu, Y Zhang, W Li, Y Zhang… - Frontiers in …, 2019 - frontiersin.org
Objective: Flow diverter devices are increasingly used in the treatment of posterior
circulation aneurysms, sometimes necessarily involving ostia of side branches and …