Inflammatory biomarkers in atherosclerosis: pentraxin 3 can become a novel marker of plaque vulnerability

…, K Yata, K Hamada, M Shibata, Y Umeda, F Asakura… - PloS one, 2014 - journals.plos.org
Inflammation is crucially involved in the development of carotid plaques. We examined the
relationship between plaque vulnerability and inflammatory biomarkers using intraoperative …

Evaluation of intraaneurysmal blood velocity by time-density curve analysis and digital subtraction angiography.

H Tenjin, F Asakura, Y Nakahara… - American journal …, 1998 - Am Soc Neuroradiology
PURPOSE Our purpose was to evaluate intraaneurysmal blood velocity by using time-density
curve analysis and digital subtraction angiography. METHODS In 31 aneurysms, …

Periprocedural hemodynamic instability with carotid angioplasty and stenting

…, N Toma, H Sakaida, K Hori, M Maeda, F Asakura… - Surgical neurology, 2008 - Elsevier
BACKGROUND: Carotid angioplasty and stenting is used for treatment of carotid stenosis.
Stent deployment may induce HDI and thereby cause systemic or neurologic deficits. This …

High-risk plaque for carotid artery stenting evaluated with 3-dimensional T1-weighted gradient echo sequence

…, Y Miura, Y Umeda, S Hatazaki, N Toma, F Asakura… - Stroke, 2013 - Am Heart Assoc
Background and Purpose— Preventing cerebral embolisms is a major concern with carotid
artery stenting (CAS). This study evaluated 3-dimensional T1-weighted gradient echo (3D …

Access site complications with carotid angioplasty and stenting

MM Taha, H Sakaida, F Asakura, M Maeda, N Toma… - Surgical neurology, 2007 - Elsevier
BACKGROUND: Carotid angioplasty and stenting is a relatively new therapeutic alternative
to CEA for treatment of carotid stenosis. The percutaneous transfemoral approach, the …

Diffusion-weighted magnetic resonance imaging in carotid angioplasty and stenting with balloon embolic protection devices

F Asakura, K Kawaguchi, H Sakaida, N Toma… - Neuroradiology, 2006 - Springer
We compared the results of two procedures to protect against distal embolism caused by
embolic debris from carotid angioplasty with stent deployment (CAS) using diffusion-weighted …

Evaluation of intra-aneurysmal blood flow by digital subtraction angiography: blood flow change after coil embolization

F Asakura, H Tenjin, N Sugawa, S Kimura, F Oki - Surgical neurology, 2003 - Elsevier
BACKGROUND: The natural course of cerebral aneurysms is related to many factors, and it
is very important that intra-aneurysmal blood flow is considered. Our group developed a …

Angioscopic observation during carotid angioplasty with stent placement

H Tanemura, S Hatazaki, F Asakura… - American journal …, 2005 - Am Soc Neuroradiology
This clinical report is the first to describe angioscopy during carotid angioplasty with stent
placement. The average observation time was 3 minutes 43 seconds in 18 cases. The view …

Tiny falx meningioma causing massive interhemispheric subdural hematoma: a case report

Y Suzuki, M Fujimoto, F Kawakita, F Asakura… - NMC Case Report …, 2018 - jstage.jst.go.jp
Bleeding from meningiomas is well known, but massive subdural hemorrhage from a very
small meningioma is rare. A 61-year-old woman presented with a sudden-onset headache …

Preclinical testing of a new clot-retrieving wire device using polyvinyl alcohol hydrogel vascular models

F Asakura, H Yilmaz, G Abdo, L Sekoranja… - Neuroradiology, 2007 - Springer
Introduction Cerebral embolism is the principal cause of cerebral infarction. Recently,
mechanical embolectomy has been proposed as an effective method. We performed a preclinical …