Prospective evaluation of carotid artery stenosis: elliptic centric contrast-enhanced MR angiography and spiral CT angiography compared with digital subtraction …

J Alvarez-Linera, J Benito-León… - American journal …, 2003 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Although digital subtraction angiography (DSA) is the
reference standard for assessing carotid arteries, it is uncomfortable for patients and has a …

Contrast-enhanced 3D MR angiography of the carotid artery: comparison with conventional digital subtraction angiography

L Remonda, P Senn, A Barth… - American journal …, 2002 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Since 1996, several preliminary studies have shown the
usefulness of contrast material–enhanced MR angiography for imaging supraaortic vessels …

Carotid artery stenosis: accuracy of contrast-enhanced MR angiography for diagnosis

PJ Nederkoorn, OEH Elgersma, Y van der Graaf… - Radiology, 2003 - pubs.rsna.org
PURPOSE: To assess accuracy of contrast material–enhanced magnetic resonance (MR)
angiography as compared with three-dimensional (3D) time-of-flight (TOF) MR angiography …

Carotid stenosis: a comparison between MR and spiral CT angiography

N Magarelli, T Scarabino, AL Simeone, F Florio… - Neuroradiology, 1998 - Springer
We performed a preliminary study comparing three-dimensional time-of-flight (3 D TOF)
magnetic resonance angiography (MRA) and spiral CT angiography (SCTA) in the detection …

CT angiographic analysis of carotid artery stenosis: comparison of manual assessment, semiautomatic vessel analysis, and digital subtraction angiography

HM Silvennoinen, S Ikonen, L Soinne… - American journal …, 2007 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: To compare multisection CT angiography (CTA) analyzed
with source/maximum intensity projection (MIP) images as well as semiautomated vessel …

Preoperative evaluation of carotid artery stenosis: comparison of contrast-enhanced MR angiography and duplex sonography with digital subtraction angiography

I Borisch, M Horn, B Butz, N Zorger… - American journal …, 2003 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Contrast-enhanced MR angiography and extracranial
color-coded duplex sonography are noninvasive, preoperative imaging modalities for …

Contrast-enhanced MR angiography (CE MRA) in the study of the carotid stenosis: comparison with digital subtraction angiography (DSA).

T Scarabino, A Carriero, GM Giannatempo… - Journal of …, 1999 - europepmc.org
Contrast-enhanced MR angiography (CE MRA) in the study of the carotid stenosis:
comparison with digital subtraction angiography (DSA). - Abstract - Europe PMC Sign in …

Carotid artery stenosis: contrast-enhanced MR angiography with two different scan times compared with digital subtraction angiography

P Sundgren, P Sunden, A Lindgren, J Lanke, S Holtås… - Neuroradiology, 2002 - Springer
Contrast enhanced magnetic resonance angiography (CE MRA) is a non-invasive
alternative to conventional digital subtraction angiography (DSA). CE MRA is increasingly …

Multi-detector row CT angiography in the assessment of carotid artery disease in symptomatic patients: comparison with rotational angiography and digital subtraction …

M Berg, Z Zhang, A Ikonen, P Sipola… - American journal …, 2005 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Compared with the single-detector technique, multi-
detector row CT angiography permits larger anatomic coverage that includes both the …

Carotid artery stenosis: prospective comparison of CT, three-dimensional gadolinium-enhanced MR, and conventional angiography

B Randoux, B Marro, F Koskas, M Duyme, M Sahel… - Radiology, 2001 - pubs.rsna.org
PURPOSE: To prospectively compare gadolinium-enhanced magnetic resonance (MR)
angiography and computed tomographic (CT) angiography with digital subtraction …