User profiles for K. Setsompop
kawin setsompopAssociate Professor, Stanford University Verified email at stanford.edu Cited by 13891 |
Ultra-fast MRI of the human brain with simultaneous multi-slice imaging
DA Feinberg, K Setsompop - Journal of magnetic resonance, 2013 - Elsevier
… slices for each k-space line through using a different phase modulated RF pulse for each
k-space line acquisition. For example, alternating the phase of every other k-space line’s …
k-space line acquisition. For example, alternating the phase of every other k-space line’s …
Blipped‐controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g‐factor penalty
… We address this by adding +ϕ/2 phase to even k y lines and -ϕ/2 phase to odd k y lines
before reconstruction. The key observation is that the phase error is the same in both the bottom …
before reconstruction. The key observation is that the phase error is the same in both the bottom …
Rapid brain MRI acquisition techniques at ultra‐high fields
… Both 3D and SMS acquisitions can be viewed as encoding data in 3D k-space rather than
2D k-space 39. This enables improvements in PI reconstruction, since data undersampling …
2D k-space 39. This enables improvements in PI reconstruction, since data undersampling …
Pushing the limits of in vivo diffusion MRI for the Human Connectome Project
K Setsompop, R Kimmlingen, E Eberlein, T Witzel… - Neuroimage, 2013 - Elsevier
… With the standard slice-GRAPPA (Std-SG), the GRAPPA kernels are calculated by solving:(1)
arg min ki S i − A sc k i 2 where S i and k i are vectors of k-space signal and GRAPPA …
arg min ki S i − A sc k i 2 where S i and k i are vectors of k-space signal and GRAPPA …
Improving diffusion MRI using simultaneous multi-slice echo planar imaging
… each k-space line. For example if alternating 180 phase shifts are applied to successive k y
lines … diffusion imaging applications since only a single RF pulse is employed for all k y lines. …
lines … diffusion imaging applications since only a single RF pulse is employed for all k y lines. …
[HTML][HTML] Connectome 2.0: Developing the next-generation ultra-high gradient strength human MRI scanner for bridging studies of the micro-, meso-and macro …
… add to the linear encoding gradients and create k-space shifts that vary in space and time. …
Image reconstruction techniques will be implemented that can model spatially dependent k-…
Image reconstruction techniques will be implemented that can model spatially dependent k-…
Parallel RF transmission with eight channels at 3 Tesla
K Setsompop, LL Wald, V Alagappan… - … in Medicine: An …, 2006 - Wiley Online Library
… The slice-selective trajectory consisted of several spokes in k z , separated in (k x ,k y ) with
spacing that corresponds to an FOV of 18 cm. Two versions of these trajectories (one with …
spacing that corresponds to an FOV of 18 cm. Two versions of these trajectories (one with …
Magnitude least squares optimization for parallel radio frequency excitation design demonstrated at 7 Tesla with eight channels
K Setsompop, LL Wald, V Alagappan… - … in Medicine: An …, 2008 - Wiley Online Library
… This is to be expected, because the spokes trajectory, which is just a few delta points in k
x -k y , allows for much less control of the in-plane excitation profile when compared with the …
x -k y , allows for much less control of the in-plane excitation profile when compared with the …
Slice‐selective RF pulses for in vivo B inhomogeneity mitigation at 7 tesla using parallel RF excitation with a 16‐element coil
K Setsompop, V Alagappan, B Gagoski… - … in Medicine: An …, 2008 - Wiley Online Library
… (k x , k y ) for these simple designs to maintain them within a regime compatible with the
linear class of large tip angle pulses proposed by Pauly et al. (31) and used for parallel Tx work …
linear class of large tip angle pulses proposed by Pauly et al. (31) and used for parallel Tx work …
High‐resolution in vivo diffusion imaging of the human brain with generalized slice dithered enhanced resolution: Simultaneous multislice (g S lider‐SMS)
Purpose To develop an efficient acquisition for high‐resolution diffusion imaging and allow
in vivo whole‐brain acquisitions at 600‐ to 700‐μm isotropic resolution. Methods We …
in vivo whole‐brain acquisitions at 600‐ to 700‐μm isotropic resolution. Methods We …