Evaluation of ultrafast wave-CAIPI MPRAGE for visual grading and automated measurement of brain tissue volume

MGF Longo, J Conklin, SF Cauley… - American Journal …, 2020 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Volumetric brain MR imaging typically has long
acquisition times. We sought to evaluate an ultrafast MPRAGE sequence based on Wave …

Highly‐accelerated volumetric brain examination using optimized wave‐CAIPI encoding

D Polak, S Cauley, SY Huang… - Journal of Magnetic …, 2019 - Wiley Online Library
Background Rapid volumetric imaging protocols could better utilize limited scanner
resources. Purpose To develop and validate an optimized 6‐minute high‐resolution …

Automated brain volumetry in patients with memory impairment: comparison of conventional and ultrafast 3D T1-weighted MRI sequences using two software …

YJ Heo, HJ Baek, S Skare, HJ Lee… - American Journal of …, 2022 - Am Roentgen Ray Soc
Please see the Editorial Comment by Alvand Hassankhani discussing this article. Please
see the Author Video associated with this article. BACKGROUND. Isotropic 3D T1-weighted …

Effects of MRI scan acceleration on brain volume measurement consistency

G Krueger, C Granziera, CR Jack Jr… - Journal of Magnetic …, 2012 - Wiley Online Library
Purpose: To evaluate the effects of recent advances in magnetic resonance imaging (MRI)
radiofrequency (RF) coil and parallel imaging technology on brain volume measurement …

[HTML][HTML] Effect of MRI acquisition acceleration via compressed sensing and parallel imaging on brain volumetry

M Dieckmeyer, AG Roy, J Senapati… - … Resonance Materials in …, 2021 - Springer
Objectives To investigate the effect of compressed SENSE (CS), an acceleration technique
combining parallel imaging and compressed sensing, on potential bias and precision of …

Leveraging clinical imaging archives for radiomics: Reliability of automated methods for brain volume measurement

VR Adduru, AM Michael, M Helguera, SA Baum… - Radiology, 2017 - pubs.rsna.org
Purpose To validate the use of thick-section clinically acquired magnetic resonance (MR)
imaging data for estimating total brain volume (TBV), gray matter (GM) volume (GMV), and …

Measuring brain volume by MR imaging: impact of measurement precision and natural variation on sample size requirements

RG Steen, RM Hamer… - American journal of …, 2007 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: To determine the sample size needed to provide
adequate statistical power in studies of brain volume by MR imaging, we examined the …

Whole brain volume measured from 1.5 T versus 3T MRI in healthy subjects and patients with multiple sclerosis

R Chu, S Tauhid, BI Glanz, BC Healy… - Journal of …, 2016 - Wiley Online Library
ABSTRACT BACKGROUND Whole brain atrophy is a putative outcome measure in
monitoring relapsing‐remitting multiple sclerosis (RRMS). With the ongoing MRI …

Normalization of cerebral volumes by use of intracranial volume: implications for longitudinal quantitative MR imaging

JL Whitwell, WR Crum, HC Watt… - American journal of …, 2001 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: MR-based volumetric measures of cerebral structures are
increasingly used for diagnostic purposes and to measure progression of atrophy. Variations …

[HTML][HTML] Parallel imaging: is GRAPPA a useful acquisition tool for MR imaging intended for volumetric brain analysis?

TL Lindholm, L Botes, EL Engman, A Frank… - BMC Medical …, 2009 - Springer
Background The work presented here investigates parallel imaging applied to T1-weighted
high resolution imaging for use in longitudinal volumetric clinical studies involving …