[HTML][HTML] Clinical outcomes of second-versus first-generation carotid stents: a systematic review and meta-analysis
A Mazurek, K Malinowski, K Rosenfield… - Journal of Clinical …, 2022 - mdpi.com
Background: Single-cohort studies suggest that second-generation stents (SGS;“mesh
stents”) may improve carotid artery stenting (CAS) outcomes by limiting peri-and …
stents”) may improve carotid artery stenting (CAS) outcomes by limiting peri-and …
Cerebral protection devices reduce periprocedural strokes during carotid angioplasty and stenting: a systematic review of the current literature
N Garg, N Karagiorgos, GT Pisimisis… - Journal of …, 2009 - journals.sagepub.com
Purpose: To compare through a systematic review of published literature the stroke
outcomes in protected and unprotected carotid artery stenting (CAS). Methods: PubMed and …
outcomes in protected and unprotected carotid artery stenting (CAS). Methods: PubMed and …
[HTML][HTML] Measurement and impact of proximal and distal tortuosity in carotid stenting procedures
G Faggioli, M Ferri, M Gargiulo, A Freyrie… - Journal of vascular …, 2007 - Elsevier
BACKGROUND: Proximal and distal carotid tortuosity is considered of paramount
importance in carotid artery stenting (CAS) procedures. Specifically, distal internal carotid …
importance in carotid artery stenting (CAS) procedures. Specifically, distal internal carotid …
B-flow and B-flow with 3D and SRI postprocessing before intervention and monitoring after stenting of the internal carotid artery
EM Jung, R Kubale, DA Clevert… - Clinical …, 2007 - content.iospress.com
Objective: To investigate the extent to which B-flow and B-flow with 3D postprocessing and
speckle reduction imaging (SRI) have advantages in appraising the morphology of a high …
speckle reduction imaging (SRI) have advantages in appraising the morphology of a high …
Successful carotid artery stenting of a dissected, highly tortuous internal carotid artery after straightening with a peripheral microguidewire
J Koge, T Iwata, S Mizuta, Y Nakamura… - Journal of Clinical …, 2018 - Elsevier
Endovascular reconstruction for carotid artery dissection (CAD) involving a highly tortuous
segment of the cervical internal carotid artery (ICA) is challenging because the tortuous ICA …
segment of the cervical internal carotid artery (ICA) is challenging because the tortuous ICA …
Modified buddy wire technique for coil embolization of posterior circulation aneurysms
K Nishino, Y Ito, H Hasegawa, B Kikuchi, Y Fujii… - Neuroradiology, 2007 - Springer
Introduction In coil embolization of a posterior circulation aneurysm, tortuosity or a small
vessel caliber frequently prevents placement of a guiding catheter in the vertebral artery …
vessel caliber frequently prevents placement of a guiding catheter in the vertebral artery …
Paradoxical brain embolism as a cause of central retinal artery occlusion: a case report
K Hayashi, Y Iguchi, K Kimura… - Journal of …, 2007 - Wiley Online Library
ABSTRACT A 79‐year‐old right‐handed woman was admitted to hospital following sudden
onset of severe visual loss in the left eye. Left central retinal artery occlusion (CRAO) was …
onset of severe visual loss in the left eye. Left central retinal artery occlusion (CRAO) was …
Carotid
ME Lockhart, LL Berland - Diagnostic Ultrasound, Second Edition, 2020 - taylorfrancis.com
The SRU consensus conference recommends that all carotid ultrasounds be performed by a
registered vascular sonographer using standards of an accreditation organization such as …
registered vascular sonographer using standards of an accreditation organization such as …
Quantifizierung von extrakraniellen A. carotis interna (ACI) Stenosen mittels Gefäßultraschall mit FKDS und B-Flow im Vergleich zur 64-Zeilen-Multidetektor-CTA, der …
T Finkenzeller, J Tacke, DA Clevert… - Ultraschall in der …, 2008 - thieme-connect.com
Ziel: Präinterventionelle Bestimmung des distalen Stenosegrades der extrakraniellen Arteria
carotis interna (ACI) durch Gefäßultraschall mittels farbkodierter Duplexsonografie (FKDS) …
carotis interna (ACI) durch Gefäßultraschall mittels farbkodierter Duplexsonografie (FKDS) …
Double balloon protection を用いた頚動脈ステント留置術での intolerance の検討
綾部純一, 久保篤彦, 渡辺正英, 前田昌宏, 田中悠介… - 脳卒中の外科, 2013 - jstage.jst.go.jp
抄録 Balloon protection effectively prevents distal embolism during carotid artery stenting
(CAS). However, some patients have occlusion intolerance to transient balloon-induced …