Spread of excitation measurements for the detection of electrode array foldovers: a prospective study comparing 3-dimensional rotational x-ray and intraoperative …

…, A Maat, F Verdam, Y Simis, B Carelsen… - Otology & …, 2009 - journals.lww.com
Objective: The optimal positioning of electrode arrays in the cochlea is extremely important.
Our standard approach is to use a 3-dimensional rotational x-ray for the intraoperative …

[HTML][HTML] A novel tool for three-dimensional roadmapping reduces radiation exposure and contrast agent dose in complex endovascular interventions

L Stangenberg, F Shuja, B Carelsen, T Elenbaas… - Journal of Vascular …, 2015 - Elsevier
B, After the vessels pertinent to the procedure had been selected, a three-dimensional (3D)
model without disturbing other anatomic structures, such as bones, is displayed. In the …

Computer-assisted planning and navigation for corrective distal radius osteotomy, based on pre-and intraoperative imaging

…, AW Schreurs, R Jonges, B Carelsen… - IEEE transactions on …, 2010 - ieeexplore.ieee.org
… Block diagram showing the image analysis steps for the preoperative procedure and b) the
intraoperative procedure. The transformation matrices and the double-contour polygons that …

CT angiography–fluoroscopy fusion imaging for percutaneous transapical access

…, F Cuesta, L Maranan, I Kronzon, B Carelsen… - JACC: Cardiovascular …, 2014 - jacc.org
… (B) Distance measurement from the LAD to the PPS and APS were made at the same z-plane.
Transapical access 2-dimensional error in relation to the left anterior descending (LAD) …

In-vivo three-dimensional carpal bone kinematics during flexion–extension and radio–ulnar deviation of the wrist: Dynamic motion versus step-wise static wrist …

…, L Blankevoort, AH Zwinderman, B Carelsen… - Journal of …, 2009 - Elsevier
An in-vivo approach to the measurement of three-dimensional motion patterns of carpal bones
in the wrist may have future diagnostic applications, particularly for ligament injuries of the …

[PDF][PDF] Cochlear implant electrode array insertion monitoring with intra-operative 3D rotational X-ray

B Carelsen, W Grolman, R Tange, GJ Streekstra… - Clin …, 2007 - academia.edu
Results We have been using the 3D-RX scanning system since February 2005 in every
cochlear implantation. Twentythree patients have been scanned according to the procedure …

Reduction of coil mass artifacts in high-resolution flat detector conebeam CT of cerebral stent-assisted coiling

…, P van de Haar, B Carelsen… - American Journal …, 2013 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Developments in flat panel angiographic C-arm systems
have enabled visualization of both the neurovascular stents and host arteries in great detail, …

Clinical experience with cone-beam CT navigation for tumor ablation

…, W Van der Sterren, A Radaelli, B Carelsen… - Journal of Vascular and …, 2015 - Elsevier
Purpose To describe clinical use and potential benefits of cone-beam computed tomography
(CT) navigation to perform image-guided percutaneous tumor ablation. Materials and …

Effect of real-time radiation dose feedback on pediatric interventional radiology staff radiation exposure

J Racadio, R Nachabe, B Carelsen, J Racadio… - Journal of Vascular and …, 2014 - Elsevier
Purpose To measure and compare individual staff radiation dose levels during interventional
radiologic (IR) procedures with and without real-time feedback to evaluate whether it has …

[HTML][HTML] Does intraoperative fluoroscopic 3D imaging provide extra information for fracture surgery?

B Carelsen, R Haverlag, DT Ubbink, JSK Luitse… - Archives of orthopaedic …, 2008 - Springer
Fracture surgery of the extremities using 2D fluoroscopy frequently fails to detect the suboptimal
positioning of implants and joint incongruities. The use of intraoperative 3D-rotational X-…