User profiles for B. Gagoski

Borjan Gagoski

Boston Children's Hospital
Verified email at childrens.harvard.edu
Cited by 5973

Blipped‐controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g‐factor penalty

K Setsompop, BA Gagoski, JR Polimeni… - Magnetic resonance …, 2012 - Wiley Online Library
… 2b represent the signal phase of even and odd k-space lines for each slice. Here, only the
slice center is considered (as the through-slice phase variation is unchanged from before). For …

Fetal MRI: a technical update with educational aspirations

…, RL Robertson, PE Grant, B Gagoski… - … Resonance Part A, 2014 - Wiley Online Library
… Using the speed of EPI, several signal averages can be employed to increase SNR and
baseline (low b-factor) and multiple high b-factor data sets of the volume can be acquired in only …

Improving diffusion MRI using simultaneous multi-slice echo planar imaging

…, J Cohen-Adad, BA Gagoski, T Raij, A Yendiki, B Keil… - Neuroimage, 2012 - Elsevier
… images at different b values, illustrating good SNR and contrast in a single shot up to b = 10,500
… This was a conservative approach that account for the relatively modest b-values (b max …

Wave‐CAIPI for highly accelerated 3D imaging

B Bilgic, BA Gagoski, SF Cauley, AP Fan… - Magnetic resonance …, 2015 - Wiley Online Library
Purpose To introduce the wave‐CAIPI (controlled aliasing in parallel imaging) acquisition
and reconstruction technique for highly accelerated 3D imaging with negligible g‐factor and …

Magnitude least squares optimization for parallel radio frequency excitation design demonstrated at 7 Tesla with eight channels

…, LL Wald, V Alagappan, BA Gagoski… - … in Medicine: An …, 2008 - Wiley Online Library
… In turn, for a fixed b, the optimal vector, z, contains values z i with a modulus of 1 and phase
equal to that of A i b. By starting with a feasible pair, b and z, and then keeping one variable …

Parallel RF transmission with eight channels at 3 Tesla

…, LL Wald, V Alagappan, B Gagoski… - … in Medicine: An …, 2006 - Wiley Online Library
… In our procedure, the B 1 fields from all of the coils were added before the Bloch-equation
calculation was performed. We note that although at low flip angles, where Eq. [1] holds, this …

Improved magnetic resonance fingerprinting reconstruction with low‐rank and subspace modeling

…, E Adalsteinsson, B Gagoski… - Magnetic resonance …, 2018 - Wiley Online Library
Purpose This article introduces a constrained imaging method based on low‐rank and
subspace modeling to improve the accuracy and speed of MR fingerprinting (MRF). Theory and …

Placental MRI: developing accurate quantitative measures of oxygenation

EA Turk, JN Stout, C Ha, J Luo, B Gagoski… - Topics in Magnetic …, 2019 - journals.lww.com
B, Assembled ex vivo placental dual perfusion chamber and coil array. C, Seven-channel …
B, 3D view of segmented fetal brains and livers in the corresponding discordant twin pair [red …

[PDF][PDF] Ex vivo fetal brain MRI: recent advances, challenges, and future directions

L Vasung, CJ Charvet, T Shiohama, B Gagoski… - Neuroimage, 2019 - Elsevier
… eg high b values) theoretically provides exceptional angular resolutions of fiber pathways …
8 Augustinack, JC, van der Kouwe AJ, Fischl B. 2013. Medial temporal cortices in ex vivo …

3D GABA imaging with real-time motion correction, shim update and reacquisition of adiabatic spiral MRSI

W Bogner, B Gagoski, AT Hess, H Bhat, MD Tisdall… - Neuroimage, 2014 - Elsevier
b) PRESS is prone to localization errors at high fields (≥ 3 T) that compromise accurate …
The B 1 + variation in the phantom as measured by a B 1 + mapping sequence was similar …