Critical care management of patients following aneurysmal subarachnoid hemorrhage: recommendations from the Neurocritical Care Society's Multidisciplinary …
Subarachnoid hemorrhage (SAH) is an acute cerebrovascular event which can have
devastating effects on the central nervous system as well as a profound impact on several other …
devastating effects on the central nervous system as well as a profound impact on several other …
Endovascular treatment of intracranial aneurysms with flow diverters: a meta-analysis
W Brinjikji, MH Murad, G Lanzino, HJ Cloft, DF Kallmes - Stroke, 2013 - Am Heart Assoc
Background and Purpose— Flow diverters are important tools in the treatment of intracranial
aneurysms. However, their impact on aneurysmal occlusion rates, morbidity, mortality, and …
aneurysms. However, their impact on aneurysmal occlusion rates, morbidity, mortality, and …
Contemporary carotid imaging: from degree of stenosis to plaque vulnerability
…, AA Rabinstein, GM Kim, A Lerman, G Lanzino - Journal of …, 2016 - thejns.org
… rabinstein, md,2 gyeong-moon Kim, md,3 amir lerman, md,4 and giuseppe lanzino, md5 …
Saba L, Mallarini G: Fissured fibrous cap of vulnerable carotid plaques and symptomaticity: are …
Saba L, Mallarini G: Fissured fibrous cap of vulnerable carotid plaques and symptomaticity: are …
Pipeline for uncoilable or failed aneurysms: results from a multicenter clinical trial
…, I Saatci, CG McDougall, I Szikora, G Lanzino… - Radiology, 2013 - pubs.rsna.org
Purpose To evaluate the safety and effectiveness of the Pipeline Embolization Device (PED;
ev3/Covidien, Irvine, Calif) in the treatment of complex intracranial aneurysms. Materials …
ev3/Covidien, Irvine, Calif) in the treatment of complex intracranial aneurysms. Materials …
International retrospective study of the pipeline embolization device: a multicenter aneurysm treatment study
…, BK Woodward, W Brinjikji, G Lanzino… - American Journal …, 2015 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Flow diverters are increasingly used in the endovascular
treatment of intracranial aneurysms. Our aim was to determine neurologic complication rates …
treatment of intracranial aneurysms. Our aim was to determine neurologic complication rates …
Age and outcome after aneurysmal subarachnoid hemorrhage: why do older patients fare worse?
G Lanzino, NF Kassell, TP Germanson… - Journal of …, 1996 - thejns.org
✓ Advanced age is a recognized prognostic indicator of poor outcome after subarachnoid
hemorrhage (SAH). The relationship of age to other prognostic factors and outcome was …
hemorrhage (SAH). The relationship of age to other prognostic factors and outcome was …
The unruptured intracranial aneurysm treatment score: a multidisciplinary consensus
Objective: We endeavored to develop an unruptured intracranial aneurysm (UIA) treatment
score (UIATS) model that includes and quantifies key factors involved in clinical decision-…
score (UIATS) model that includes and quantifies key factors involved in clinical decision-…
Long-term clinical and angiographic outcomes following pipeline embolization device treatment of complex internal carotid artery aneurysms: five-year results of the …
…, EI Levy, CG McDougall, I Szikora, G Lanzino… - …, 2017 - journals.lww.com
BACKGROUND: Early and mid-term safety and efficacy of aneurysm treatment with the
Pipeline Embolization Device (PED) has been well demonstrated in prior studies. OBJECTIVE: …
Pipeline Embolization Device (PED) has been well demonstrated in prior studies. OBJECTIVE: …
Stent-assisted coiling in acutely ruptured intracranial aneurysms: a qualitative, systematic review of the literature
KD Bodily, HJ Cloft, G Lanzino… - American journal …, 2011 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: The use of stents for treatment of morphologically unfavorable,
acutely ruptured aneurysms is avoided by most operators because of concerns about …
acutely ruptured aneurysms is avoided by most operators because of concerns about …
Efficacy and current limitations of intravascular stents for intracranial internal carotid, vertebral, and basilar artery aneurysms
G Lanzino, AK Wakhloo, RD Fessler, ML Hartney… - Journal of …, 1999 - thejns.org
Object. Results of previous in vitro and in vivo experimental studies have suggested that
placement of a porous stent within the parent artery across the aneurysm neck may …
placement of a porous stent within the parent artery across the aneurysm neck may …