Abdominal MR imaging with a volumetric interpolated breath-hold examination

NM Rofsky, VS Lee, G Laub, MA Pollack, GA Krinsky… - Radiology, 1999 - pubs.rsna.org
PURPOSE: To compare a T1-weighted, three-dimensional (3D), gradient-echo (GRE)
sequence for magnetic resonance (MR) imaging of the body (volumetric interpolated breath-hold …

" Black blood" T2-weighted inversion-recovery MR imaging of the heart.

OP Simonetti, JP Finn, RD White, G Laub, DA Henry - Radiology, 1996 - pubs.rsna.org
PURPOSE: To develop a short-inversion-time inversion-recovery (STIR) magnetic resonance
imaging pulse sequence for evaluating the myocardium that is relatively free of flow and …

Self‐gated cardiac cine MRI

AC Larson, RD White, G Laub… - … in Medicine: An …, 2004 - Wiley Online Library
The need for ECG gating presents many difficulties in cardiac magnetic resonance imaging (CMRI).
Real‐time imaging techniques eliminate the need for ECG gating in cine CMRI, but …

MR evaluation of ventricular function: true fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: feasibility study

J Barkhausen, SG Ruehm, M Goyen, T Buck, G Laub… - Radiology, 2001 - pubs.rsna.org
Short- and long-axis cine magnetic resonance (MR) images were obtained with a standard
fast low-angle shot, or FLASH, sequence and a first-generation true fast imaging with steady-…

Cardiac MR Imaging: State of the Technology1

JP Finn, K Nael, V Deshpande, O Ratib, G Laub - Radiology, 2006 - pubs.rsna.org
Recent developments in magnetic resonance (MR) imaging of the heart have refocused
attention on the potential of MR and continue to attract intense interest within the radiology and …

HASTE MR imaging: description of technique and preliminary results in the abdomen

…, D Thomasson, MA Brown, GA Laub - Journal of Magnetic …, 1996 - Wiley Online Library
HASTE (HAlf fourier Single‐shot Turbo spin‐Echo) is a single‐section T2‐weighted
sequence that acquires images in less than 1 second. Images are breathing independent and …

3D magnetization‐prepared true‐FISP: a new technique for imaging coronary arteries

VS Deshpande, SM Shea, G Laub… - … in Medicine: An …, 2001 - Wiley Online Library
The purpose of this work was to develop an ECG‐triggered, segmented 3D true‐FISP (fast
imaging with steady‐state precession) technique to improve the signal‐to‐noise ratio (SNR) …

Signal targeting with alternating radiofrequency (STAR) sequences: application to MR angiography

…, B Siewert, M Adamis, J Gaa, G Laub… - Magnetic resonance …, 1994 - Wiley Online Library
We describe a time of flight subtraction method for cine MR angiography that provides nearly
perfect suppression of background signal intensity with excellent flow contrast. The method …

Hepatic MR imaging with a dynamic contrast-enhanced isotropic volumetric interpolated breath-hold examination: feasibility, reproducibility, and technical quality

VS Lee, MT Lavelle, NM Rofsky, G Laub… - Radiology, 2000 - pubs.rsna.org
PURPOSE: To evaluate the feasibility, reproducibility, and technical quality of a dynamic
contrast material–enhanced isotropic three-dimensional (3D) volumetric interpolated breath-…

Coronary arteries: three-dimensional MR imaging with retrospective respiratory gating.

…, PK Woodard, PJ Dhawale, RM Kroeker, G Laub… - Radiology, 1996 - pubs.rsna.org
Thin-section, three-dimensional (3D) gradient-echo magnetic resonance imaging of the
coronary arteries was performed without and with retrospective respiratory gating in 12 healthy …