New techniques in CT angiography
MM Lell, K Anders, M Uder, E Klotz, H Ditt… - Radiographics, 2006 - pubs.rsna.org
Computed tomographic (CT) angiography has been improved significantly with the introduction
of four- to 64-section spiral CT scanners, which offer rapid acquisition of isotropic data …
of four- to 64-section spiral CT scanners, which offer rapid acquisition of isotropic data …
Recent and upcoming technological developments in computed tomography: high speed, low dose, deep learning, multienergy
MM Lell, M Kachelrieß - Investigative radiology, 2020 - journals.lww.com
The advent of computed tomography (CT) has revolutionized radiology, and this revolution
is still going on. Starting as a pure head scanner, modern CT systems are now able to …
is still going on. Starting as a pure head scanner, modern CT systems are now able to …
Evolution in computed tomography: the battle for speed and dose
MM Lell, JE Wildberger, H Alkadhi… - Investigative …, 2015 - journals.lww.com
The advent of computed tomography (CT) has revolutionized radiology. Starting as head-only
scanners, modern CT systems are now capable of performing whole-body examinations …
scanners, modern CT systems are now capable of performing whole-body examinations …
Aggregated neutrophil extracellular traps limit inflammation by degrading cytokines and chemokines
Gout is characterized by an acute inflammatory reaction and the accumulation of neutrophils
in response to monosodium urate (MSU) crystals. Inflammation resolves spontaneously …
in response to monosodium urate (MSU) crystals. Inflammation resolves spontaneously …
Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition
…, A Kuettner, WG Daniel, M Uder, MM Lell - European heart …, 2010 - academic.oup.com
Aims We evaluated the feasibility and image quality of a new scan mode for coronary computed
tomography angiography (CTA) with an effective dose of less than 1 mSv. Methods and …
tomography angiography (CTA) with an effective dose of less than 1 mSv. Methods and …
Normalized metal artifact reduction (NMAR) in computed tomography
…, R Raupach, M Lell, B Schmidt, M Kachelrieß - Medical …, 2010 - Wiley Online Library
Purpose: While modern clinical CT scanners under normal circumstances produce high
quality images, severe artifacts degrade the image quality and the diagnostic value if metal …
quality images, severe artifacts degrade the image quality and the diagnostic value if metal …
Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions
H Greess, H Wolf, U Baum, M Lell, M Pirkl… - European …, 2000 - Springer
This study investigated the potential of attenuation-based on-line modulation of tube current
to reduce the dose of computed tomography (in milliamperes) without loss in image quality. …
to reduce the dose of computed tomography (in milliamperes) without loss in image quality. …
Frequency split metal artifact reduction (FSMAR) in computed tomography
…, R Raupach, M Lell, B Schmidt, M Kachelrieß - Medical …, 2012 - Wiley Online Library
Purpose : The problem of metal artifact reduction (MAR) is almost as old as the clinical use
of computed tomography itself. When metal implants are present in the field of measurement, …
of computed tomography itself. When metal implants are present in the field of measurement, …
High-pitch spiral acquisition: a new scan mode for coronary CT angiography
…, T Allmendinger, M Petersilka, K Anders, M Lell… - Journal of …, 2009 - Elsevier
Coronary CT angiography allows high-quality imaging of the coronary arteries when state-of-the-art
CT systems are used. However, radiation exposure has been a concern. We …
CT systems are used. However, radiation exposure has been a concern. We …
Performance of today's dual energy CT and future multi energy CT in virtual non‐contrast imaging and in iodine quantification: a simulation study
…, HP Schlemmer, M Lell, M Kachelrieß - Medical …, 2015 - Wiley Online Library
… We want to calibrate the material decomposition for a VNC image (m = 1) and an iodine
image (m = 2), ie, M = 2. Water is therefore mapped to g 1 = 1 and g 2 = 0, and the iodine …
image (m = 2), ie, M = 2. Water is therefore mapped to g 1 = 1 and g 2 = 0, and the iodine …