User profiles for S. Conolly

Steven Conolly

- Verified email at berkeley.edu - Cited by 12512

SJ Connolly

- Verified email at qub.ac.uk - Cited by 2533

Magnetic particle imaging (MPI) for NMR and MRI researchers

…, LR Croft, JJ Konkle, K Lu, B Zheng, SM Conolly - Journal of Magnetic …, 2013 - Elsevier
… ( t ) where ρ ˆ ( x ) is the “native” MPI image of nanoparticle distribution, x s (t) is the instantaneous
position of the FFP, and x s ( t ) is the instantaneous velocity of the FFP. Here we define …

X‐space MPI: magnetic nanoparticles for safe medical imaging

…, KM Krishnan, DV Schaffer, SM Conolly - Advanced …, 2012 - Wiley Online Library
… tracer H sat [A/m], the gradient field strength G [A/m/m] and the FFP slew rate x' s (t) [m/s].
The product Gx' s (t) [A/m/s] is simply the slew rate of the field used to excite the sample. …

A review of magnetic particle imaging and perspectives on neuroimaging

…, G Song, L Pisani, T Doyle, S Conolly… - American Journal …, 2019 - Am Soc Neuroradiology
Magnetic particle imaging is an emerging tomographic technique with the potential for
simultaneous high-resolution, high-sensitivity, and real-time imaging. Magnetic particle imaging is …

Positive contrast magnetic resonance imaging of cells labeled with magnetic nanoparticles

…, MV McConnell, JM Pauly, SM Conolly - … in Medicine: An …, 2005 - Wiley Online Library
… (b) By applying an RF pulse with carrier frequency ω s and bandwidth BW, the regions with
… would be excited by a band-selective RF pulse with ω s = −20 ppm and BW = 10 ppm. Similar …

[BOOK][B] Religion, Law, and Power: The Making of Protestant Ireland 1660-1760: The Making of Protestant Ireland 1660-1760

SJ Connolly - 1992 - books.google.com
… SJ Connolly's scholarly and wide-ranging study examines these developments and sets
them in their historical context. The Ireland that emerges from his lucid and penetrating analysis …

The X-space formulation of the magnetic particle imaging process: 1-D signal, resolution, bandwidth, SNR, SAR, and magnetostimulation

PW Goodwill, SM Conolly - IEEE transactions on medical …, 2010 - ieeexplore.ieee.org
… and we see that MPI’s bandwidth requirements increase linearly with nanoparticle properties
, gradient strength , and scanning rate [see Fig. 7(a)]. Evaluating the FWHM with realistic …

Variable-rate selective excitation

S Conolly, D Nishimura, A Macovski… - Journal of Magnetic …, 1988 - Elsevier
… Often the peak-magnitude limitations on one’s RF amplifier constrain the selective pulse
one may use. For example, the peak amplitude of a fixed-duration sine pulse increases linearly …

Magnetic particle imaging: a novel in vivo imaging platform for cancer detection

…, SJ Kemp, KM Krishnan, PW Goodwill, SM Conolly - Nano …, 2017 - ACS Publications
… The z frames (5.76 s per frame) are acquired at 2 mm increments, allowing for the stitching
required … by the fitting of M(H) data to a Langevin function (following Chantrell’s method (27)). …

Magnetic Particle Imaging-Guided Heating in Vivo Using Gradient Fields for Arbitrary Localization of Magnetic Hyperthermia Therapy

…, PW Goodwill, B Zheng, C Rinaldi, SM Conolly - ACS …, 2018 - ACS Publications
Image-guided treatment of cancer enables physicians to localize and treat tumors with great
precision. Here, we present in vivo results showing that an emerging imaging modality, …

Biogenic gas nanostructures as ultrasonic molecular reporters

…, M Yin, FS Foster, DV Schaffer, SM Conolly - Nature …, 2014 - nature.com
… rate of 15 frames/s for ∼100 s. A volume of 50 µl Halo gas vesicles in PBS was infused ∼10
s after the start of the experiment at a flow rate of 0.6 ml min −1 . After 65 s, a burst pulse …