Pathologic conditions of the hypothenar eminence: evaluation with multidetector CT and MR imaging

AG Blum, JP Zabel, R Kohlmann, T Batch, K Barbara… - Radiographics, 2006 - pubs.rsna.org
Pain, weakness, and sensory loss occur frequently in the hypothenar eminence. However,
clinical examination is difficult and nonspecific, and the prescribed imaging technique may be …

Evidence-based recommendations for musculoskeletal kinematic 4D-CT studies using wide area-detector scanners: a phantom study with cadaveric correlation

…, AS Formery, G Hossu, D Winninger, T Batch… - European …, 2017 - Springer
Propose To establish evidence-based recommendations for musculoskeletal kinematic 4D-CT
on wide area-detector CT. Materials and methods In order to assess factors influencing …

Current multiplanar imaging of the stapes

P Henrot, S Iochum, T Batch… - American journal …, 2005 - Am Soc Neuroradiology
PURPOSE: CT analysis of the stapes is difficult in the axial plane (AP), because of its oblique
orientation. Oblique axial reformations could provide a more precise analysis of the stapes …

L'arthro-IRM, le gold-standard actuel?

A Blum, R Detreille, T Batch, D Roch, M Louis… - Revue du Rhumatisme …, 2010 - Elsevier
Depuis près de 15 ans, l’arthro-IRM est devenue la méthode d’imagerie de référence de l’épaule.
Les publications la concernant sont nettement plus nombreuses que celles portant sur …

Assessment of the use of a saline chaser to reduce the volume of contrast medium in abdominal CT

…, S Iochum-Duchamps, T Batch… - American Journal of …, 2006 - Am Roentgen Ray Soc
OBJECTIVE. The purpose of this study was to investigate, first, the effect on enhancement of
the liver and aorta during abdominal CT of the use of saline solution as a partial substitute …

Réduction de dose dans l'exploration du rachis lombaire grâce au scanner 320-détecteurs: étude initiale

A Gervaise, M Louis, T Batch, D Loeuille, A Noel… - Journal de …, 2010 - Elsevier
Objectif. Comparer la dose délivrée et la qualité d’image entre un scanner lombaire réalisé
en mode hélicoïdal et en mode Wide volume grâce au scanner 320-détecteurs. Patients et …

Vascular renal anatomy and the ureteropelvic junction: preoperative multidetector CT scanning with split-bolus injection as a predictor of laparoscopic findings

B Sauer, M Flocquet, T Batch, A Blum… - Journal of …, 2008 - liebertpub.com
Purpose: To compare multidetector CT scan (MDCT) results with intraoperative findings in
the detection of an inferior-pole pedicle crossing the ureteropelvic junction. Patients and …

Dose optimization and reduction in CT of the musculoskeletal system including the spine

A Blum, A Noël, D Winninger, T Batch, T Ludig… - Radiation dose from …, 2007 - Springer
Since its introduction in the 1970s, computerized tomography (CT) has played an important
role in the diagnosis of musculoskeletal disorders. It rapidly became the examination of …

[PDF][PDF] Traitement par le procédé SBR (Sequencing Batch Reactor) des lixiviats de la décharge publique non contrôlée de la ville de Taza (Maroc)

…, F Lamchouri, M Merzouki, H Toufik - International Journal of …, 2018 - researchgate.net
Aujourd’hui, les énormes difficultés que rencontrent certaines décharges nationales se sont
répétées, notamment des «comportements» inattendues, très différents de ce qui avait été …

[PDF][PDF] MDCT: What Next?

A Blum, R Detreille, JP Zabel, T Batch, D Roch, M Louis - 2008 - mdct.net
The advent of multi-detector-row computed tomography (MDCT) in 1998 was a major
technological breakthrough. It not only improved the management of patients for whom CT was …