C-arm flat detector computed tomography: the technique and its applications in interventional neuro-radiology

M Kamran, S Nagaraja, JV Byrne - Neuroradiology, 2010 - Springer
Introduction Flat detector computed tomography (FDCT) is an imaging tool that generates
three-dimensional (3-D) volumes from data obtained during C-arm rotation using CT-like …

A proposed parent vessel geometry—based categorization of saccular intracranial aneurysms: computational flow dynamics analysis of the risk factors for lesion …

T Hassan, EV Timofeev, T Saito, H Shimizu… - Journal of …, 2005 - thejns.org
Object. The authors created a simple, broadly applicable classification of saccular
intracranial aneurysms into three categories: sidewall (SW), sidewall with branching vessel …

Size and location of ruptured and unruptured intracranial aneurysms measured by 3-dimensional rotational angiography

J Beck, S Rohde, J Berkefeld, V Seifert, A Raabe - Surgical neurology, 2006 - Elsevier
OBJECTIVE: The aim of the study was to report about accurate size and location of a
consecutive series of ruptured and unruptured aneurysms taking the complex 3-dimensional …

Validation of CFD simulations of cerebral aneurysms with implication of geometric variations

Y Hoi, SH Woodward, M Kim, DB Taulbee, H Meng - 2006 - asmedigitalcollection.asme.org
Background. Computational fluid dynamics (CFD) simulations using medical-image-based
anatomical vascular geometry are now gaining clinical relevance. This study aimed at …

Silicone models as basic training and research aid in endovascular neurointervention—a single-center experience and review of the literature

S Paramasivam, G Baltsavias, E Psatha, G Matis… - Neurosurgical …, 2014 - Springer
The rapid development and wider use of neurointerventional procedures have increased the
demand for a comprehensive training program for the trainees, in order to safely and …

Reproducibility of image-based computational models of intracranial aneurysm: a comparison between 3D rotational angiography, CT angiography and MR …

Y Ren, GZ Chen, Z Liu, Y Cai, GM Lu, ZY Li - Biomedical engineering …, 2016 - Springer
Background Reconstruction of patient-specific biomechanical model of intracranial
aneurysm has been based on different imaging modalities. However, different imaging …

3D‐printed, patient‐specific intracranial aneurysm models: From clinical data to flow experiments with endovascular devices

MS Pravdivtseva, E Peschke, T Lindner… - Medical …, 2021 - Wiley Online Library
Purpose Flow models of intracranial aneurysms (IAs) can be used to test new and existing
endovascular treatments with flow modulation devices (FMDs). Additionally, 4D flow …

Study of extracted geometry effect on patient-specific cerebral aneurysm model with different threshold coefficient (Cthres)

SH Lim, MAHM Adib, MS Abdullah, NHM Taib… - CFD Letters, 2020 - akademiabaru.com
The recent diagnostic assessment of cerebrovascular disease makes use of computational
fluid dynamics (CFD) to quantify blood flow and determine the hemodynamics factors …

The hemodynamic alterations induced by the vascular angular deformation in stent-assisted coiling of bifurcation aneurysms

W Jeong, MH Han, K Rhee - Computers in Biology and Medicine, 2014 - Elsevier
The hemodynamic changes induced by stent deployment and vascular remodeling in
bifurcation aneurysms were investigated using computational fluid dynamics. The stent …

3D rotational digital subtraction angiography may underestimate intracranial aneurysms: findings from two basilar aneurysms

LD Jou, A Mohamed, DH Lee… - American Journal of …, 2007 - Am Soc Neuroradiology
3D digital subtraction angiography (DSA) allows clinicians to review intracranial aneurysms
and other vascular lesions. We report 2 basilar aneurysms that were imaged by both 3D …